Effects of a microbubble contrast agent on breast tumors: Computer-assisted quantitative assessment with color Doppler US - Early experience

被引:92
|
作者
Huber, S
Helbich, T
Kettenbach, J
Dock, W
Zuna, I
Delorme, S
机构
[1] Lainz Hosp, Dept Radiol, A-1130 Vienna, Austria
[2] Univ Hosp Vienna, Dept Radiol, Vienna, Austria
[3] German Canc Res Ctr, Dept Oncol Diagnost & Therapy, D-6900 Heidelberg, Germany
关键词
breast neoplasms; diagnosis; US; computers; diagnostic aid; microbubbles; ultrasound; (US); contrast media; Doppler studies;
D O I
10.1148/radiology.208.2.9680580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate objectively the effects of a microbubble contrast agent on the color Doppler ultrasound (US) examination of breast lesions. MATERIALS AND METHODS: Forty-seven patients aged 23-71 years underwent color Doppler US before and after intravenous injection of a microbubble contrast agent. A 3-minute computer-assisted assessment of the color pixel density (CPD) was used to evaluate objectively the increase in the number of color Doppler US signals, the transit time of the microbubble bolus, and the potential additional differential diagnostic information. RESULTS: Peak CPD at contrast agent-enhanced color Doppler US was 14.3% +/- 8.1 (mean +/- 1 standard deviation) for carcinomas and 9.3% +/- 4.9 for benign lesions (P = .04). The time to peak enhancement was shorter in carcinomas (38 seconds +/- 20) than in benign tumors (71 seconds +/- 48, P = .02). Final CPD was close or equal to baseline values. With the median of 13% for peak CPD as a threshold, the sensitivity for this parameter was 55%, the specificity was 79%, and the accuracy was 62% (P = .04). For a median time to peak of 50 seconds, the sensitivity was 84%, specificity was 57%, and the accuracy was 76%. CONCLUSION: After microbubble contrast agent injection, carcinomas and benign lesions behave differently in degree,onset, and duration of Doppler US enhancement. High interindividual variability and temporal variations in the Doppler US signal still limit the value of these criteria for prospective diagnosis.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 28 条
  • [21] Enhancement of power Doppler signals from breast lesions with the ultrasound contrast agent EchoGen emulsion: Subjective and quantitative assessment - Discussion
    Schlief
    Albrecht
    Watson
    Correas
    Gertz
    Wiggins
    Mattrey
    ACADEMIC RADIOLOGY, 1998, 5 : S199 - S199
  • [22] Classification of breast mass lesions on dynamic contrast-enhanced magnetic resonance imaging by a computer-assisted diagnosis system based on quantitative analysis
    Yin, Jiandong
    Yang, Jiawen
    Jiang, Zejun
    ONCOLOGY LETTERS, 2019, 17 (03) : 2623 - 2630
  • [23] Ablation of High Intensity Focused Ultrasound Combined with SonoVue on Rabbit VX2 Liver Tumors: Assessment with Conventional Gray-Scale US, Conventional Color/Power Doppler US, Contrast-Enhanced Color Doppler US, and Contrast-Enhanced Pulse-Inversion Harmonic US
    Wen Luo
    Xiaodong Zhou
    Guangbin He
    Qiuyang Li
    Xiaoying Zheng
    Zhiyong Fan
    Qing Liu
    Ming Yu
    Zenghui Han
    Jun Zhang
    Yunqiu Qian
    Annals of Surgical Oncology, 2008, 15
  • [24] Ablation of high intensity focused ultrasound combined with SonoVue on rabbit VX2 liver tumors: Assessment with conventional gray-scale US, conventional color/power Doppler US, contrast-enhanced color Doppler US, and contrast-enhanced pulse-inversion harmonic US
    Luo, Wen
    Zhou, Xiaodong
    He, Guangbin
    Li, Qiuyang
    Zheng, Xiaoying
    Fan, Zhiyong
    Liu, Qing
    Yu, Ming
    Han, Zenghui
    Zhang, Jun
    Qian, Yunqiu
    ANNALS OF SURGICAL ONCOLOGY, 2008, 15 (10) : 2943 - 2953
  • [25] Computer-assisted diagnosis for early stage pleural mesothelioma -: Towards automated detection and quantitative assessment of pleural thickenings from thoracic CT images
    Chaisaowong, K.
    Jaeger, P.
    Vogel, S.
    Knepper, A.
    Kraus, I.
    Aach, T.
    METHODS OF INFORMATION IN MEDICINE, 2007, 46 (03) : 324 - 331
  • [26] Quantitative assessment of angiogenesis and tumor vessel architecture by computer-assisted digital image analysis: Effects of VEGF-toxin conjugate on tumor microvessel density
    Wild, R
    Ramakrishnan, S
    Sedgewick, J
    Griffioen, AW
    MICROVASCULAR RESEARCH, 2000, 59 (03) : 368 - 376
  • [27] Dynamic contrast-enhanced Doppler ultrasound (DCE-US) is a useful radiological assessment to early predict the outcome of patients with gastrointestinal stromal tumors (GIST) treated with imatinib (IM).
    Lamuraglia, M.
    Le Cesne, A.
    Chami, L.
    Bonvalot, S.
    Terrier, P.
    Tursz, T.
    Roche, A.
    Lassau, N.
    JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (18) : 529S - 529S
  • [28] EFFECTS OF ADENOSINE INFUSION ON SYSTOLIC AND DIASTOLIC LEFT-VENTRICULAR FUNCTION AFTER CORONARY-ARTERY BYPASS-SURGERY - EVALUATION BY COMPUTER-ASSISTED QUANTITATIVE 2-D AND DOPPLER-ECHOCARDIOGRAPHY
    HOULTZ, E
    RICKSTEN, SE
    MILOCCO, I
    GUSTAVSSON, T
    CAIDAHL, K
    ANESTHESIA AND ANALGESIA, 1995, 80 (01): : 47 - 53