Effects of a microbubble contrast agent on breast tumors: Computer-assisted quantitative assessment with color Doppler US - Early experience

被引:92
|
作者
Huber, S
Helbich, T
Kettenbach, J
Dock, W
Zuna, I
Delorme, S
机构
[1] Lainz Hosp, Dept Radiol, A-1130 Vienna, Austria
[2] Univ Hosp Vienna, Dept Radiol, Vienna, Austria
[3] German Canc Res Ctr, Dept Oncol Diagnost & Therapy, D-6900 Heidelberg, Germany
关键词
breast neoplasms; diagnosis; US; computers; diagnostic aid; microbubbles; ultrasound; (US); contrast media; Doppler studies;
D O I
10.1148/radiology.208.2.9680580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate objectively the effects of a microbubble contrast agent on the color Doppler ultrasound (US) examination of breast lesions. MATERIALS AND METHODS: Forty-seven patients aged 23-71 years underwent color Doppler US before and after intravenous injection of a microbubble contrast agent. A 3-minute computer-assisted assessment of the color pixel density (CPD) was used to evaluate objectively the increase in the number of color Doppler US signals, the transit time of the microbubble bolus, and the potential additional differential diagnostic information. RESULTS: Peak CPD at contrast agent-enhanced color Doppler US was 14.3% +/- 8.1 (mean +/- 1 standard deviation) for carcinomas and 9.3% +/- 4.9 for benign lesions (P = .04). The time to peak enhancement was shorter in carcinomas (38 seconds +/- 20) than in benign tumors (71 seconds +/- 48, P = .02). Final CPD was close or equal to baseline values. With the median of 13% for peak CPD as a threshold, the sensitivity for this parameter was 55%, the specificity was 79%, and the accuracy was 62% (P = .04). For a median time to peak of 50 seconds, the sensitivity was 84%, specificity was 57%, and the accuracy was 76%. CONCLUSION: After microbubble contrast agent injection, carcinomas and benign lesions behave differently in degree,onset, and duration of Doppler US enhancement. High interindividual variability and temporal variations in the Doppler US signal still limit the value of these criteria for prospective diagnosis.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 28 条
  • [1] Effects of microbubble contrast agent on breast tumors: Computer-assisted quantitative assessment with color Doppler US
    Huber, S
    Helbich, TH
    Kettenbach, J
    Zuna, I
    Delorme, S
    Dock, WI
    RADIOLOGY, 1997, 205 : 1479 - 1479
  • [2] Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors
    Kettenbach, J
    Helbich, TH
    Huber, A
    Zuna, I
    Dock, W
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 53 (02) : 238 - 244
  • [3] Effects of microbubble contrast agent on breast tumors: Preliminary results of computer-assisted quantitative assessment with power Doppler US
    Kettenbach, J
    Zuna, I
    Helbich, T
    Huber, S
    Delorme, S
    Lechner, G
    RADIOLOGY, 1997, 205 : 836 - 836
  • [4] BREAST-TUMORS - COMPUTER-ASSISTED QUANTITATIVE ASSESSMENT WITH COLOR DOPPLER US
    HUBER, S
    DELORME, S
    KNOPP, MV
    JUNKERMANN, H
    ZUNA, I
    VONFOURNIER, D
    VANKAICK, G
    RADIOLOGY, 1994, 192 (03) : 797 - 801
  • [5] Microbubble contrast agent for color Doppler US: Effect on breast masses
    Kedar, RP
    Cosgrove, D
    McCready, VR
    Bamber, JC
    Carter, ER
    RADIOLOGY, 1996, 198 (03) : 679 - 686
  • [6] Nonpalpable breast lesions: Evaluation with power Doppler US and a microbubble contrast agent - Initial experience
    Moon, WK
    Im, JG
    Noh, DY
    Han, MC
    RADIOLOGY, 2000, 217 (01) : 240 - 246
  • [7] Computer-assisted quantitative evaluation of color Doppler images in the assessment of tumor vascularization
    Huber, S
    RADIOLOGE, 1998, 38 (10): : 867 - 871
  • [8] Nonpalpable breast lesions: Evaluation with power Doppler US and a microbubble contrast agent
    Moon, WK
    Im, J
    Noh, D
    Yeon, KM
    Han, MC
    RADIOLOGY, 1999, 213P : 371 - 371
  • [9] COLOR DOPPLER SONOGRAPHY IN BREAST-TUMORS - COMPUTER-AIDED QUANTITATIVE ASSESSMENT
    DELORME, S
    ZUNA, I
    HUBER, S
    ALBERT, B
    LOHR, F
    KNOPP, V
    JUNKERMANN, H
    VANKAICK, G
    TUMORDIAGNOSTIK & THERAPIE, 1995, 16 (05) : 180 - 186
  • [10] Twin fetuses: Intravascular microbubble US contrast agent administration - Early experience
    Denbow, ML
    Welsh, AW
    Taylor, MJ
    Blomley, MJK
    Cosgrove, DO
    Fisk, NM
    RADIOLOGY, 2000, 214 (03) : 724 - 728