A Simplest Method of Flap Monitoring

被引:24
作者
Sakakibara, Shunsuke [1 ,2 ]
Hashikawa, Kazunobu [1 ]
Omori, Makoto [3 ]
Terashi, Hiroto [1 ]
Tahara, Shinya [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Plast Surg, Chuo Ku, Kobe, Hyogo 6500017, Japan
[2] Kobe Univ, Grad Sch Med, Div Aesthet Med Sci, Kobe, Hyogo 6500017, Japan
[3] Rokko Isl Hosp, Dept Aesthet Med Sci, Kobe, Hyogo, Japan
关键词
LASER-DOPPLER FLOWMETER; BLOOD-FLOW; MICRODIALYSIS; VIABILITY; TRANSFERS; PROBE;
D O I
10.1055/s-0030-1251562
中图分类号
R61 [外科手术学];
学科分类号
摘要
[No abstract available]
引用
收藏
页码:433 / 434
页数:2
相关论文
共 15 条
[1]   Differentiation between arterial and venous vessel occlusion by simultaneous measurement with laser Doppler flowmetry and photoplethysmography [J].
Galla, TJ ;
Hellekes, D ;
Feller, AM .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1999, 15 (01) :67-72
[2]   Laser Doppler flowmeter monitoring of free-tissue transfers: Blood flow in normal and complicated cases [J].
Heller, L ;
Levin, LS ;
Klitzman, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 107 (07) :1739-1745
[3]   Continuous tissue oxygen tension measurement as a monitor of free-flap viability [J].
Hirigoyen, MB ;
Blackwell, KE ;
Zhang, WX ;
Silver, L ;
Weinberg, H ;
Urken, ML .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (03) :763-773
[4]   THE LASER DOPPLER FLOWMETER FOR MICRO-VASCULAR MONITORING - A PRELIMINARY-REPORT [J].
JONES, BM ;
MAYOU, BJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1982, 35 (02) :147-149
[5]   EXPERIMENTAL AND CLINICAL MONITORING OF FREE JEJUNAL TRANSFERS USING AN IMPLANTABLE ULTRASONIC DOPPLER PROBE [J].
JONES, NF ;
ROCKE, AM ;
SWARTZ, WM ;
KLEIN, A .
BRITISH JOURNAL OF PLASTIC SURGERY, 1989, 42 (03) :274-280
[6]   Microdialysis in clinical practice -: Monitoring intraoral free flops [J].
Jyränki, J ;
Suominen, S ;
Vuola, J ;
Bäck, L .
ANNALS OF PLASTIC SURGERY, 2006, 56 (04) :387-393
[7]   Two practical devices for monitoring temperature [J].
Kayikçioglu, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (05) :1778-1779
[8]   Direct monitoring using an endoscope for buried flaps [J].
Mizunuma, M ;
Yanai, A ;
Seno, H ;
Nishida, M ;
Beppu, T .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 104 (03) :884-884
[9]   Assessment of skin flaps using optically based methods for measuring blood flow and oxygenation [J].
Payette, JR ;
Kohlenberg, E ;
Leonardi, L ;
Pabbies, A ;
Kerr, P ;
Liu, KZ ;
Sowa, MG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 115 (02) :539-546
[10]   Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy [J].
Repez, Andrej ;
Oroszy, Dominika ;
Arnez, Zoran M. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (01) :71-77