Temperature measurement on neurological pulse generators during MR scans

被引:37
作者
Kainz, Wolfgang [1 ]
Neubauer, Georg [1 ]
Ueberbacher, Richard [1 ]
Alesch, Francois [2 ]
Chan, Dulciana Dias [3 ]
机构
[1] ARC Seibersdorf Res, Dept Mobile Commun Safety, Seibersdorf, Austria
[2] AKH Vienna, Dept Neurosurg, Vienna, Austria
[3] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
关键词
D O I
10.1186/1475-925X-1-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
According to manufacturers of both magnetic resonance imaging (MRI) machines, and implantable neurological pulse generators (IPGs), MRI is contraindicated for patients with IPGs. A major argument for this restriction is the risk to induce heat in the leads due to the electromagnetic field, which could be dangerous for the surrounding brain parenchyma. The temperature change on the surface of the case of an ITREL-III (Medtronic Inc., Minneapolis, MN) and the lead tip during MRI was determined. An anatomical realistic and a cubic phantom, filled with phantom material mimicking human tissue, and a typical lead configuration were used to imitate a patient who carries an IPG for deep brain stimulation. The measurements were performed in a 1.5 T and a 3.0 T MRI. 2.1 degrees C temperature increases at the lead tip uncovered the lead tip as the most critical part concerning heating problems in IPGs. Temperature increases in other locations were low compared to the one at the lead tip. The measured temperature increase of 2.1 degrees C can not be considered as harmful to the patient. Comparison with the results of other studies revealed the avoidance of loops as a practical method to reduce heating during MRI procedures.
引用
收藏
页数:8
相关论文
共 10 条
  • [1] STIMULATION OF THE VENTRAL INTERMEDIATE THALAMIC NUCLEUS IN TREMOR DOMINATED PARKINSONS-DISEASE AND ESSENTIAL TREMOR
    ALESCH, F
    PINTER, MM
    HELSCHER, RJ
    FERTL, L
    BENABID, AL
    KOOS, WT
    [J]. ACTA NEUROCHIRURGICA, 1995, 136 (1-2) : 75 - 81
  • [2] The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz
    Gabriel, S
    Lau, RW
    Gabriel, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) : 2251 - 2269
  • [3] THE EFFECT OF MAGNETIC-RESONANCE IMAGERS ON IMPLANTED NEUROSTIMULATORS
    GLEASON, CA
    KAULA, NF
    HRICAK, H
    SCHMIDT, RA
    TANAGHO, EA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (01): : 81 - 94
  • [4] Kainz W, 2000, THESIS
  • [5] EFFECT ON PARKINSONIAN SIGNS AND SYMPTOMS OF BILATERAL SUBTHALAMIC NUCLEUS STIMULATION
    LIMOUSIN, P
    POLLAK, P
    BENAZZOUZ, A
    HOFFMANN, D
    LEBAS, JF
    BROUSSOLLE, E
    PERRET, JE
    BENABID, AL
    [J]. LANCET, 1995, 345 (8942): : 91 - 95
  • [6] Neurostimulators: Potential for excessive heating of deep brain stimulation electrodes during magnetic resonance imaging
    Rezai, AR
    Finelli, D
    Nyenhuis, JA
    Shellock, FG
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 488 - 489
  • [7] Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla
    Rezai, AR
    Finelli, D
    Nyenhuis, JA
    Hrdlicka, G
    Tkach, J
    Sharan, A
    Rugieri, P
    Stypulkowski, PH
    Shellock, FG
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (03) : 241 - 250
  • [8] Schmid G, 1998, AUVA REPORT, V19
  • [9] Magnetic resonance imaging with implanted neurostimulators:: An in vitro and in vivo study
    Tronnier, VM
    Staubert, A
    Hähnel, S
    Sarem-Aslani, A
    [J]. NEUROSURGERY, 1999, 44 (01) : 118 - 125
  • [10] Uberbacher R, 2001, THESIS