Clinical Results With the Light Adjustable Intraocular Lens After Cataract Surgery

被引:9
作者
von Mohrenfels, Christoph Winkler [1 ]
Salgado, Josefina [1 ]
Khoramnia, Ramin [1 ]
Maier, Mathias [1 ]
Lohmann, Chris P. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Augenheilkunde, D-81675 Munich, Germany
关键词
POWER CALCULATION; CORRECTING ASTIGMATISM; ACCURACY LIMITS; IOL CALCULATION; AXIAL LENGTH; EYES; FORMULAS; IMPLANTATION; INCISION;
D O I
10.3928/1081597X-20090617-12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: The accuracy of intraocular lens (IOL) calculation is limited by the variation of the measurement of corneal power, axial length, anterior chamber depth, and effective postoperative lens position. Therefore, IOL predictability is limited. The aim of this study was to evaluate the performance of the novel light adjustable lens (LAL, Calhoun Vision). METHODS: Ten eyes with cataracts (seven patients) were included. After standard phacoemulsification, the LAL was implanted. Two to 3 weeks after surgery, all IOL adjustments had been completed. Preoperatively, pre-adjustment, pre-lock-in, and 1 month post-lock-in, a full ophthalmic examination including objective (autorefraction) and subjective refraction (ie, manifest uncorrected visual acuity [UCVA] and manifest best spectacle-corrected visual acuity [BSCVA]) and topography were performed. RESULTS: All cataract surgeries were performed with no complications. Two weeks after surgery, the mean refraction was +0.78 +/- 0.79 diopters (D). After adjustment and lock-in, the refraction was -0.07 +/- 0.21 D. In 4 of 10 eyes, second adjustments were necessary. One month after surgery, all patients were within +/- 0.50 D of the intended refraction. Preoperatively, the cylinder was 0.88 +/- 0.77 D, but was reduced after adjustments to 0.15 +/- 0.20 D. Mean UCVA was 1.02, and all eyes gained at least two lines on the Snellen visual acuity test (ie, BSCVA) after surgery. CONCLUSIONS: The LAL is a new IOL with the ability to correct up to 2.00 D of sphere and cylinder after implantation. Our first clinical results are promising and indicate effective safety and stability. U Refract Surg. 2010;26:314-3201 doi:10.3928/1081597X-20090617-12
引用
收藏
页码:314 / 320
页数:7
相关论文
共 50 条
  • [31] Clinical Evaluation of Macular Thickness Changes in Cataract Surgery Using a LightAdjustable Intraocular Lens
    Hengerer, Fritz H.
    Mueller, Michael
    Dick, H. Burkhard
    Conrad-Hengerer, Ina
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (04) : 250 - 254
  • [32] Ultrasound biomicroscopic study of the stability of intraocular lens implants after phacoemulsification cataract surgery
    Ang, Ghee Soon
    Duncan, Laura
    Atta, Hatem R.
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (02) : 168 - 172
  • [33] Timely vitrectomy without intraocular lens removal for acute endophthalmitis after cataract surgery
    Guo, Hai-Xia
    Xie, Ruo-Tian
    Wang, Yun
    You, Cai-Yun
    Liu, Yuan-Yuan
    Meng, Xiang-Da
    Yu, Jin-Guo
    Yan, Hua
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (06) : 1011 - 1014
  • [34] Anterior chamber depth, intraocular lens position, and refractive outcomes after cataract surgery
    Engren, Anna-Lotta
    Behndig, Anders
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04) : 572 - 577
  • [35] Variations in intraocular lens injector dimensions and corneal incision architecture after cataract surgery
    Arboleda, Alejandro
    Arrieta, Esdras
    Aguilar, Mariela C.
    Sotolongo, Krystal
    Nankivil, Derek
    Parel, Jean-Marie A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (05) : 656 - 661
  • [36] Vector analysis of astigmatic changes after cataract surgery with toric intraocular lens implantation
    Alio, Jorge L.
    Pinero, David P.
    Tomas, Javier
    Aleson, Alicia
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1038 - 1049
  • [37] Hydrophobic Trifocal Toric Intraocular Lens Outcomes in Japanese Eyes After Cataract Surgery
    Akahoshi, Takayuki
    [J]. CLINICAL OPHTHALMOLOGY, 2024, 18 : 2021 - 2031
  • [38] Clinical Outcomes of TECNIS Toric Intraocular Lens Implantation after Cataract Removal in Patients with Corneal Astigmatism
    Waltz, Kevin L.
    Featherstone, Kristen
    Tsai, Linda
    Trentacost, Debbie
    [J]. OPHTHALMOLOGY, 2015, 122 (01) : 39 - 47
  • [39] Femtosecond Laser-Assisted Cataract Surgery in Phakic Intraocular Lens With Cataract
    Kaur, Manpreet
    Sahu, Suman
    Sharma, Namrata
    Titiyal, Jeewan S.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (02) : 131 - 134
  • [40] Cataract surgery with a small-aperture intraocular lens after previous corneal refractive surgery: Visual outcomes and spectacle independence
    Agarwal, Smita
    Thornell, Erin M.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (09) : 1150 - 1154