Clinical Results With the Light Adjustable Intraocular Lens After Cataract Surgery

被引:9
作者
von Mohrenfels, Christoph Winkler [1 ]
Salgado, Josefina [1 ]
Khoramnia, Ramin [1 ]
Maier, Mathias [1 ]
Lohmann, Chris P. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Augenheilkunde, D-81675 Munich, Germany
关键词
POWER CALCULATION; CORRECTING ASTIGMATISM; ACCURACY LIMITS; IOL CALCULATION; AXIAL LENGTH; EYES; FORMULAS; IMPLANTATION; INCISION;
D O I
10.3928/1081597X-20090617-12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: The accuracy of intraocular lens (IOL) calculation is limited by the variation of the measurement of corneal power, axial length, anterior chamber depth, and effective postoperative lens position. Therefore, IOL predictability is limited. The aim of this study was to evaluate the performance of the novel light adjustable lens (LAL, Calhoun Vision). METHODS: Ten eyes with cataracts (seven patients) were included. After standard phacoemulsification, the LAL was implanted. Two to 3 weeks after surgery, all IOL adjustments had been completed. Preoperatively, pre-adjustment, pre-lock-in, and 1 month post-lock-in, a full ophthalmic examination including objective (autorefraction) and subjective refraction (ie, manifest uncorrected visual acuity [UCVA] and manifest best spectacle-corrected visual acuity [BSCVA]) and topography were performed. RESULTS: All cataract surgeries were performed with no complications. Two weeks after surgery, the mean refraction was +0.78 +/- 0.79 diopters (D). After adjustment and lock-in, the refraction was -0.07 +/- 0.21 D. In 4 of 10 eyes, second adjustments were necessary. One month after surgery, all patients were within +/- 0.50 D of the intended refraction. Preoperatively, the cylinder was 0.88 +/- 0.77 D, but was reduced after adjustments to 0.15 +/- 0.20 D. Mean UCVA was 1.02, and all eyes gained at least two lines on the Snellen visual acuity test (ie, BSCVA) after surgery. CONCLUSIONS: The LAL is a new IOL with the ability to correct up to 2.00 D of sphere and cylinder after implantation. Our first clinical results are promising and indicate effective safety and stability. U Refract Surg. 2010;26:314-3201 doi:10.3928/1081597X-20090617-12
引用
收藏
页码:314 / 320
页数:7
相关论文
共 50 条
  • [21] Intraocular lens power calculation in pediatric cataract surgery: A narrative review
    Wojcik-Niklewska, Bogumila
    Nocon-Bratek, Martyna
    Szala, Klaudia
    MEDICINE, 2025, 104 (14) : e42072
  • [22] The neutralization of corneal astigmatism during cataract surgery using toric intraocular lens: results
    Centurion, Virgilio
    Lacava, Augusto Cezar
    Caballero, Juan Carlos
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2009, 68 (02) : 76 - 82
  • [23] Update on pediatric cataract surgery and intraocular lens implantation
    Lin, Alice A.
    Buckley, Edward G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2010, 21 (01) : 55 - 59
  • [24] Intraocular lens power estimation for future emmetropia in pediatric cataract surgery
    Lottelli, Antonio Carlos
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2022, 85 (03) : 249 - 254
  • [25] Intraocular lens optic capture in pediatric cataract surgery
    Xie, Ying-Bin
    Ren, Mei-Yu
    Wang, Qi
    Wang, Li-Hua
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (08) : 1403 - 1410
  • [26] Morphologic changes in the anterior segment using ultrasound biomicroscopy after cataract surgery and intraocular lens implantation
    Unsal, Erkan
    Eltutar, Kadir
    Muftuoglu, Ilkay K.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (01) : 31 - 38
  • [27] Pediatric cataract surgery with hydrophilic acrylic intraocular lens
    Kleinmann, Guy
    Zaugg, Brian
    Apple, David J.
    Bleik, Jamal
    JOURNAL OF AAPOS, 2013, 17 (04): : 367 - 370
  • [28] Improving accuracy for intraocular lens selection in cataract surgery
    Brandsdorfer, Ari
    Kang, Joann J.
    CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) : 324 - 328
  • [29] Lens-based glaucoma surgery: Using cataract surgery to reduce intraocular pressure
    Brown, Reay H.
    Zhong, Le
    Lynch, Mary G.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (08) : 1255 - 1262
  • [30] Biometric and Intraocular Pressure Change after Cataract Surgery
    Bilak, Semsettin
    Simsek, Ali
    Capkin, Musa
    Guler, Mete
    Bilgin, Burak
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (04) : 464 - 470