Clinical Results With the Light Adjustable Intraocular Lens After Cataract Surgery

被引:9
|
作者
von Mohrenfels, Christoph Winkler [1 ]
Salgado, Josefina [1 ]
Khoramnia, Ramin [1 ]
Maier, Mathias [1 ]
Lohmann, Chris P. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Augenheilkunde, D-81675 Munich, Germany
关键词
POWER CALCULATION; CORRECTING ASTIGMATISM; ACCURACY LIMITS; IOL CALCULATION; AXIAL LENGTH; EYES; FORMULAS; IMPLANTATION; INCISION;
D O I
10.3928/1081597X-20090617-12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: The accuracy of intraocular lens (IOL) calculation is limited by the variation of the measurement of corneal power, axial length, anterior chamber depth, and effective postoperative lens position. Therefore, IOL predictability is limited. The aim of this study was to evaluate the performance of the novel light adjustable lens (LAL, Calhoun Vision). METHODS: Ten eyes with cataracts (seven patients) were included. After standard phacoemulsification, the LAL was implanted. Two to 3 weeks after surgery, all IOL adjustments had been completed. Preoperatively, pre-adjustment, pre-lock-in, and 1 month post-lock-in, a full ophthalmic examination including objective (autorefraction) and subjective refraction (ie, manifest uncorrected visual acuity [UCVA] and manifest best spectacle-corrected visual acuity [BSCVA]) and topography were performed. RESULTS: All cataract surgeries were performed with no complications. Two weeks after surgery, the mean refraction was +0.78 +/- 0.79 diopters (D). After adjustment and lock-in, the refraction was -0.07 +/- 0.21 D. In 4 of 10 eyes, second adjustments were necessary. One month after surgery, all patients were within +/- 0.50 D of the intended refraction. Preoperatively, the cylinder was 0.88 +/- 0.77 D, but was reduced after adjustments to 0.15 +/- 0.20 D. Mean UCVA was 1.02, and all eyes gained at least two lines on the Snellen visual acuity test (ie, BSCVA) after surgery. CONCLUSIONS: The LAL is a new IOL with the ability to correct up to 2.00 D of sphere and cylinder after implantation. Our first clinical results are promising and indicate effective safety and stability. U Refract Surg. 2010;26:314-3201 doi:10.3928/1081597X-20090617-12
引用
收藏
页码:314 / 320
页数:7
相关论文
共 50 条
  • [1] Six-Month Clinical Results with the Light Adjustable Lens
    Salgado, J. P.
    Khoramnia, R.
    Schweiger, B.
    Lohmann, C.
    von Mohrenfels, C. Winkler
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (12) : 966 - 970
  • [2] Refractive Results after Implantation of a Light-Adjustable Intraocular Lens in Postrefractive Surgery Cataract Patients
    Brierley, Lawrence
    OPHTHALMOLOGY, 2013, 120 (10) : 1968 - 1972
  • [3] Correction of Residual Hyperopia After Cataract Surgery Using the Light Adjustable Intraocular Lens Technology
    Chayet, Arturo
    Sandstedt, Christian A.
    Chang, Shiao H.
    Rhee, Paul
    Tsuchiyama, Barbara
    Schwartz, Daniel
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 392 - 397
  • [4] Clinical Outcomes After Cataract Surgery With a New Transitional Toric Intraocular Lens
    Ferreira, Tiago B.
    Berendschot, T. J. M.
    Ribeiro, Filomena J.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 452 - +
  • [5] Adjustment of Sphero-Cylindrical Refractive Errors in Hyperopic Eyes: 6-Month Results after Cataract Surgery and Implantation of a Light-Adjustable Intraocular Lens
    Hengerer, F. H.
    Conrad-Hengerer, I.
    Huetz, W. W.
    Dick, B.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (09) : 729 - 734
  • [6] Impact of intraocular lens characteristics on intraocular lens dislocation after cataract surgery
    Mayer-Xanthaki, Christoph Fidel
    Pregartner, Gudrun
    Hirnschall, Nino
    Falb, Thomas
    Sommer, Michael
    Findl, Oliver
    Wedrich, Andreas
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (11) : 1510 - 1514
  • [7] Clinical Results of Cataract Surgery Using the ARTIS® PL E Intraocular Lens
    Park, Ella Seo Yeon
    Chung, Byung Hoon
    Jun, Ikhyun
    Kim, Tae-im
    Seo, Kyoung Yul
    Kim, Eung Kweon
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (02): : 134 - 141
  • [8] Clinical Evaluation of an Ultraviolet Light Adjustable Intraocular Lens Implanted after Cataract Removal Eighteen Months Follow-up
    Hengerer, Fritz H.
    Dick, H. Burkhard
    Conrad-Hengerer, Ina
    OPHTHALMOLOGY, 2011, 118 (12) : 2382 - 2388
  • [9] Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
    Lubinski, Wojciech
    Kazmierczak, Beata
    Gronkowska-Serafin, Jolanta
    Podbordczynska-Jodko, Karolina
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [10] Intraocular lens exchange or explantation post cataract surgery
    Dvivedi, Arundhati
    Murthy, Somasheila, I
    Manga, Sukesh
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (11) : 2031 - 2036