Anodic adsorptive stripping voltammetric determination of atrazine in spiked soil samples with a gold microelectrode

被引:10
作者
Morais, S [1 ]
Tavares, O [1 ]
Baptista-Paíga, PC [1 ]
Delerue-Matos, C [1 ]
机构
[1] Inst Politecn Porto, Inst Super Engn, Requimte, Dept Engn Quim, Oporto, Portugal
关键词
atrazine; gold microelectrode; anodic adsorptive stripping; voltammetry; spiked soil samples;
D O I
10.1081/AL-200040352
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave-assisted solvent extraction was combined with anodic adsorptive Stripping voltammetry at a gold microelectrode to extract and quantify the herbicide atrazine in spiked soil samples. A systematic study of the experimental parameters affecting the stripping response was carried out by square-wave voltammetry. The voltammetric procedure is based on controlled adsorptive accumulation of atrazine at the potential of 0.35 V (versus Ag/AgCl) in the presence of Britton-Robinson buffer pH (2.0). The limit of detection obtained for a 30 sec collection time was 4.3 x 10(-7) mol L-1. Recovery experiments, at the 1 mug g(-1) level of spiking, gave good results for the global procedure, and the values found were comparable to those obtained by HPLC.
引用
收藏
页码:3271 / 3286
页数:16
相关论文
共 26 条
[1]   Analytical methods for biological monitoring of exposure to pesticides: a review [J].
Barr, DB ;
Needham, LL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2) :5-29
[2]   Recent extraction techniques for solid matrices-supercritical fluid extraction, pressurized fluid extraction and microwave-assisted extraction: their potential and pitfalls [J].
Camel, V .
ANALYST, 2001, 126 (07) :1182-1193
[3]   Rapid identification of carbendazim and linuron by adsorptive stripping on a carbon fiber ultramicroelectrode [J].
de la Huebra, MJG ;
Hernández, P ;
Ballesteros, Y ;
Hernández, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08) :853-856
[4]   Determination of linuron in soil by stripping voltammetry with a carbon fiber microelectrode [J].
de la Huebra, MJG ;
Hernández, P ;
Ballesteros, Y ;
Hernández, L .
TALANTA, 2001, 54 (06) :1077-1085
[5]   Determination of carbendazim in soil samples by anodic stripping voltammetry using a carbon fiber ultramicroelectrode [J].
de la Huebra, MJG ;
Hernández, P ;
Nieto, O ;
Ballesteros, Y ;
Hernández, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (05) :474-478
[6]  
*EPA, 2000, 45268 OH, P1
[7]  
Eskilsson CS, 2000, J CHROMATOGR A, V902, P227
[8]   Electrochemical methods in pesticides control [J].
Garrido, EM ;
Delerue-Matos, C ;
Lima, JLFC ;
Brett, AMO .
ANALYTICAL LETTERS, 2004, 37 (09) :1755-1791
[9]  
GRABEC I, 1996, FRESEN J ANAL CHEM, V354, P770
[10]   EC(EE) processes in the reduction of some 2-methylthio-4,6-di(alkylamino)-1,3,5-triazines on mercury electrodes [J].
Higuera, MJ ;
Galvín, RM ;
Mellado, JMR ;
Montoya, MR .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (01) :30-35