A compact and stable eddy covariance set-up for methane measurements using off-axis integrated cavity output spectroscopy

被引:74
作者
Hendriks, D. M. D. [1 ]
Dolman, A. J. [1 ]
van der Molen, M. K. [1 ]
van Huissteden, J. [1 ]
机构
[1] Vrije Univ Amsterdam, Fac Earth & Life Sci, Dept Hydrol & Geoenvironm Sci, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.5194/acp-8-431-2008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A Fast Methane Analyzer (FMA) is assessed for its applicability in a closed path eddy covariance field set-up in a peat meadow. The FMA uses off-axis integrated cavity output spectroscopy combined with a highly specific narrow band laser for the detection of CH4 and strongly reflective mirrors to obtain a laser path length of 2-20x10(3) m. Statistical testing and a calibration experiment showed high precision (7.8x10(-3) ppb) and accuracy (<0.30%) of the instrument, while no drift was observed. The instrument response time was determined to be 0.10 s. In the field set-up, the FMA is attached to a scroll pump and combined with a 3-axis ultrasonic anemometer and an open path infrared gas analyzer for measurements of carbon dioxide and water vapour. The power-spectra and co-spectra of the instruments were satisfactory for 10 Hz sampling rates. Due to erroneous measurements, spikes and periods of low turbulence the data series consisted for 26% of gaps. Observed CH4 fluxes consisted mainly of emission, showed a diurnal cycle, but were rather variable over. The average CH4 emission was 29.7 nmol m(-2) s(-1), while the typical maximum CH4 emission was approximately 80.0 nmol m(-2) s(-1) and the typical minimum flux was approximately 0.0 nmol m(-2) s(-1). The correspondence of the measurements with flux chamber measurements in the footprint was good and the observed CH4 emission rates were comparable with eddy covariance CH4 measurements in other peat areas. Additionally, three measurement techniques with lower sampling frequencies were simulated, which might give the possibility to measure CH4 fluxes without an external pump and save energy. Disjunct eddy covariance appeared to be the most reliable substitute for 10 Hz eddy covariance, while relaxed eddy accumulation gave reliable estimates of the fluxes over periods in the order of days or weeks.
引用
收藏
页码:431 / 443
页数:13
相关论文
共 42 条
[21]   Eddy flux measurements of methane over the fen "Murnauer Moos", 11°11′E, 47°39′N, using a fast tunable diode laser spectrometer [J].
Kormann, R ;
Müller, H ;
Werle, P .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (14) :2533-2544
[22]   Suitability of quantum cascade laser spectroscopy for CH4 and N2O eddy covariance flux measurements [J].
Kroon, P. S. ;
Hensen, A. ;
Jonker, H. J. J. ;
Zahniser, M. S. ;
van 't Veen, W. H. ;
Vermeulen, A. T. .
BIOGEOSCIENCES, 2007, 4 (05) :715-728
[23]   Design and field application of an automated cartridge sampler for VOC concentration and flux measurements [J].
Kuhn, U ;
Dindorf, T ;
Ammann, C ;
Rottenberger, S ;
Guyon, P ;
Holzinger, R ;
Ausma, S ;
Kenntner, T ;
Helleis, F ;
Kesselmeier, J .
JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (06) :568-576
[24]   EDDY-COVARIANCE CO2 FLUX MEASUREMENTS USING OPEN-PATH AND CLOSED-PATH CO2 ANALYZERS - CORRECTIONS FOR ANALYZER WATER-VAPOR SENSITIVITY AND DAMPING OF FLUCTUATIONS IN AIR SAMPLING TUBES [J].
LEUNING, R ;
MONCRIEFF, J .
BOUNDARY-LAYER METEOROLOGY, 1990, 53 (1-2) :63-76
[25]   COMPARISON OF EDDY-COVARIANCE MEASUREMENTS OF CO2 FLUXES BY OPEN-PATH AND CLOSED-PATH CO2 ANALYZERS [J].
LEUNING, R ;
KING, KM .
BOUNDARY-LAYER METEOROLOGY, 1992, 59 (03) :297-311
[26]  
Lloyd CR, 1997, J HYDROL, V188, P400, DOI 10.1016/S0022-1694(96)03184-8
[27]   FREQUENCY-RESPONSE CORRECTIONS FOR EDDY-CORRELATION SYSTEMS [J].
MOORE, CJ .
BOUNDARY-LAYER METEOROLOGY, 1986, 37 (1-2) :17-35
[28]   Correction of sonic anemometer angle of attack errors [J].
Nakai, T ;
van der Molen, MK ;
Gash, JHC ;
Kodama, Y .
AGRICULTURAL AND FOREST METEOROLOGY, 2006, 136 (1-2) :19-30
[29]   High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors [J].
Nelson, DD ;
McManus, B ;
Urbanski, S ;
Herndon, S ;
Zahniser, MS .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (14) :3325-3335
[30]   Integrated cavity output analysis of ultra-weak absorption [J].
O'Keefe, A .
CHEMICAL PHYSICS LETTERS, 1998, 293 (5-6) :331-336