Motion robust Imaging Photoplethysmography in defocus blurring

被引:2
作者
Wu, Yuheng [1 ]
Kong, Lingqin [1 ]
Chen, Fei [1 ]
Zhao, Yuejin [1 ]
Dong, Liquan [1 ]
Liu, Ming [1 ]
Hui, Mei [1 ]
Liu, Xiaohua [1 ]
Li, Cuiling [1 ]
Wang, Weijie [1 ]
机构
[1] Beijing Inst Technol, Beijing Key Lab Precis Photoelect Measuring Instr, Sch Optoelect, Beijing 100081, Peoples R China
来源
APPLICATIONS OF DIGITAL IMAGE PROCESSING XLII | 2019年 / 11137卷
基金
中国国家自然科学基金;
关键词
Imaging photoplethysmography; defocus blurring; non-contact; motion; NONCONTACT;
D O I
10.1117/12.2527655
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Non-contact, imaging photoplethysmography (IPPG) uses video sequence to measure variations in light absorption, caused by blood volume pulsations, to extract cardiopulmonary parameters including heart rate (HR), pulse rate variability, and respiration rate. Previous researches most focused on extraction of these vital signs base on the focus video, which require a static and focusing environment. However, little has been reported about the influence of defocus blur on IPPG signal's extraction. In this research, we established an IPPG optical model in defocusing motion conditions. It was found that the IPPG signal is not sensitive to defocus blur by analysis the light intensity distribution in the defocus images. In this paper, a real-time measurement of heart rate in defocus and motion conditions based on IPPG was proposed. Automatically select and track the region of interest (ROI) by constructing facial coordinates through facial key points detection, obtained the IPPG signal. The signal is de-noised to obtain the spectrum by the wavelet filtering, color-distortion filter (CDF) and fast Fourier transform (FFT). The peak of the spectrum is corresponded to heartbeats. Experimental results on a data set of 30 subjects show that the physiological parameters include heart rate and pulse wave, derived from the defocus images captured by the IPPG system, exhibit characteristics comparable to conventional the blood volume pulse (BVP) sensor. Contrast experiment show that the difference between the results measured by both methods is within 3 beat per minute (BPM). This technology has significant potential for advancing personal health care and telemedicine in motion situation.
引用
收藏
页数:8
相关论文
共 20 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]  
Bobbia Serge, 2016, IEEE 23 INT C PATT R
[3]   Robust Pulse Rate From Chrominance-Based rPPG [J].
de Haan, Gerard ;
Jeanne, Vincent .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) :2878-2886
[4]  
Feng LT, 2014, INT CONF DIGIT SIG, P18, DOI 10.1109/ICDSP.2014.6900813
[5]   Non-contact measurement of oxygen saturation with an RGB camera [J].
Guazzi, Alessandro R. ;
Villarroel, Mauricio ;
Jorge, Joao ;
Daly, Jonathan ;
Frise, Matthew C. ;
Robbins, Peter A. ;
Tarassenko, Lionel .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (09) :3320-3338
[6]   Photoplethysmographic imaging of high spatial resolution [J].
Kamshilin, Alexei A. ;
Miridonov, Serguei ;
Teplov, Victor ;
Saarenheimo, Riku ;
Nippolainen, Ervin .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (04) :996-1006
[7]   Blind image deconvolution [J].
Kundur, D ;
Hatzinakos, D .
IEEE SIGNAL PROCESSING MAGAZINE, 1996, 13 (03) :43-64
[8]  
Lempe G., 2013, Bildverarbeitung f{\\\\"u}r die Medizin 2013, P99, DOI [DOI 10.1007/978-3-642-36480-8, 10.1007/978-3-642-36480-8{, DOI 10.1007/978-3-642-36480-8_19]
[9]  
Lewandowska M., 2011, 2011 Federated Conference on Computer Science and Information Systems (FedCSIS), P405
[10]  
Li X., 2014, IEEE CVPR