Incidence, Predictors, and Outcome of Conduction Disorders After Transcatheter Self-Expandable Aortic Valve Implantation

被引:138
作者
Fraccaro, Chiara [1 ]
Buja, Gianfranco [1 ]
Tarantini, Giuseppe [1 ]
Gasparetto, Valeria [1 ]
Leoni, Loira [1 ]
Razzolini, Renato [1 ]
Corrado, Domenico [1 ]
Bonato, Raffaele [3 ]
Basso, Cristina [4 ]
Thiene, Gaetano [4 ]
Gerosa, Gino [2 ]
Isabella, Giambattista [1 ]
Iliceto, Sabin [1 ]
Napodano, Massimo [1 ]
机构
[1] Univ Padua, Div Cardiol, Dept Cardiac Thorac & Vasc Sci, Padua, Italy
[2] Univ Padua, Div Cardiac Surg, Dept Cardiac Thorac & Vasc Sci, Padua, Italy
[3] Univ Padua, Inst Anesthesia, Padua, Italy
[4] Univ Padua, Dept Med Diagnost Sci & Special Therapies, Padua, Italy
关键词
ATRIOVENTRICULAR-BLOCK; REPLACEMENT; STENOSIS; BIOPROSTHESIS; DISTURBANCES; PROSTHESIS;
D O I
10.1016/j.amjcard.2010.10.054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aims of the present study were to investigate the incidence and characteristics of conduction disorders (CDs) after transcatheter aortic valve implantation (TAVI), to analyze the predictors of permanent pacemaker (PPM) implantation, and to evaluate the outcomes of CDs over time. In particular, we sought to investigate whether the depth of deployment and other technical aspects of valve implantation might predict the need for PPM implantation after TAVI. TAVI has been reported to favor the onset or worsening of CDs often requiring PPM implantation. A total of 70 patients with aortic stenosis due to dystrophic calcification underwent TAVI with third-generation Core Valve Revalving System from May 2007 to April 2009. We collected electrocardiograms at baseline, during TAVI, during hospitalization and at the 1-, 3-, 6-, and 12-month follow-up visits thereafter. The clinical, anatomic, and procedural variables were tested to identify the predictors of PPM implantation. The PPM dependency at follow-up was analyzed. Six patients were excluded from the analysis because of a pre-existing PPM. Of the 64 patients, 32 (50%) had one or more atrioventricular-intraventricular CDs at baseline. TAVI induced a worsening in the CDs in 49 (77%) of the 64 patients, with 25 (39%) requiring in-hospital PPM implantation. On multivariate analysis, the independent predictors of PPM implantation were the depth of the prosthesis implantation p = 0.039) and the pre-existing right bundle branch block (p = 0.046). A trend in the recovery of the CDs over time was recorded, although 2 patients required PPM implantation 1 month after discharge for late complete atrioventricular block. In conclusion, TAVI often induces or worsens CDs, requiring PPM in more than one third of patients, although a trend in the recovery of CDs during the midterm was recorded. The independent predictors of PPM implantation were the depth of prosthesis implantation and pre-existing right bundle
引用
收藏
页码:747 / 754
页数:8
相关论文
共 17 条
[11]   Totally percutaneous valve replacement for severe aortic regurgitation in a degenerating bioprosthesis [J].
Napodano, Massimo ;
Cutolo, Ada ;
Fraccaro, Chiara ;
Tarantini, Giuseppe ;
Bonato, Raffaele ;
Bianco, Roberto ;
Gerosa, Gino ;
Iliceto, Sabino ;
Ramondo, Angelo .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (04) :1027-1028
[12]  
Napodano M, 2009, J AM COLL CARDIOL, V53, P219, DOI 10.1016/j.jacc.2008.02.090
[13]  
Piazza Nicolo, 2008, EuroIntervention, V4, P242, DOI 10.4244/EIJV4I2A43
[14]   Early and Persistent Intraventricular Conduction Abnormalities and Requirements for Pacemaking After Percutaneous Replacement of the Aortic Valve [J].
Piazza, Nicolo ;
Onuma, Yoshinobu ;
Jesserun, Emile ;
Kint, Peter Paul ;
Maugenest, Anne-Marie ;
Anderson, Robert H. ;
de Jaegere, Peter P. Th ;
Serruys, Patrick W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) :310-316
[15]   PERCUTANEOUS BALLOON VALVULOPLASTY FOR CALCIFIC AORTIC-STENOSIS - A TREATMENT SINE CURE [J].
SERRUYS, PW ;
LUIJTEN, HE ;
BEATT, KJ ;
DIMARIO, C ;
DEFEYTER, PJ ;
ESSED, CE ;
ROELANDT, JRTC ;
VANDENBRAND, M .
EUROPEAN HEART JOURNAL, 1988, 9 (07) :782-794
[16]   Atrioventricular Block After Transcatheter Balloon Expandable Aortic Valve Implantation [J].
Sinhal, Ajay ;
Altwegg, Lukas ;
Pasupati, Sanjeevan ;
Humphries, Karin H. ;
Allard, Michael ;
Martin, Paul ;
Cheung, Anson ;
Ye, Jian ;
Kerr, Charles ;
Lichtenstein, Sam V. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) :305-309
[17]   CRITERIA FOR INTRAVENTRICULAR-CONDUCTION DISTURBANCES AND PRE-EXCITATION [J].
WILLEMS, JL ;
DEMEDINA, EOR ;
BERNARD, R ;
COUMEL, P ;
FISCH, C ;
KRIKLER, D ;
MAZUR, NA ;
MEIJLER, FL ;
MOGENSEN, L ;
MORET, P ;
PISA, Z ;
RAUTAHARJU, PM ;
SURAWICZ, B ;
WATANABE, Y ;
WELLENS, HJJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (06) :1261-1275