Incidence, Predictors, and Outcome of Conduction Disorders After Transcatheter Self-Expandable Aortic Valve Implantation

被引:138
作者
Fraccaro, Chiara [1 ]
Buja, Gianfranco [1 ]
Tarantini, Giuseppe [1 ]
Gasparetto, Valeria [1 ]
Leoni, Loira [1 ]
Razzolini, Renato [1 ]
Corrado, Domenico [1 ]
Bonato, Raffaele [3 ]
Basso, Cristina [4 ]
Thiene, Gaetano [4 ]
Gerosa, Gino [2 ]
Isabella, Giambattista [1 ]
Iliceto, Sabin [1 ]
Napodano, Massimo [1 ]
机构
[1] Univ Padua, Div Cardiol, Dept Cardiac Thorac & Vasc Sci, Padua, Italy
[2] Univ Padua, Div Cardiac Surg, Dept Cardiac Thorac & Vasc Sci, Padua, Italy
[3] Univ Padua, Inst Anesthesia, Padua, Italy
[4] Univ Padua, Dept Med Diagnost Sci & Special Therapies, Padua, Italy
关键词
ATRIOVENTRICULAR-BLOCK; REPLACEMENT; STENOSIS; BIOPROSTHESIS; DISTURBANCES; PROSTHESIS;
D O I
10.1016/j.amjcard.2010.10.054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aims of the present study were to investigate the incidence and characteristics of conduction disorders (CDs) after transcatheter aortic valve implantation (TAVI), to analyze the predictors of permanent pacemaker (PPM) implantation, and to evaluate the outcomes of CDs over time. In particular, we sought to investigate whether the depth of deployment and other technical aspects of valve implantation might predict the need for PPM implantation after TAVI. TAVI has been reported to favor the onset or worsening of CDs often requiring PPM implantation. A total of 70 patients with aortic stenosis due to dystrophic calcification underwent TAVI with third-generation Core Valve Revalving System from May 2007 to April 2009. We collected electrocardiograms at baseline, during TAVI, during hospitalization and at the 1-, 3-, 6-, and 12-month follow-up visits thereafter. The clinical, anatomic, and procedural variables were tested to identify the predictors of PPM implantation. The PPM dependency at follow-up was analyzed. Six patients were excluded from the analysis because of a pre-existing PPM. Of the 64 patients, 32 (50%) had one or more atrioventricular-intraventricular CDs at baseline. TAVI induced a worsening in the CDs in 49 (77%) of the 64 patients, with 25 (39%) requiring in-hospital PPM implantation. On multivariate analysis, the independent predictors of PPM implantation were the depth of the prosthesis implantation p = 0.039) and the pre-existing right bundle branch block (p = 0.046). A trend in the recovery of the CDs over time was recorded, although 2 patients required PPM implantation 1 month after discharge for late complete atrioventricular block. In conclusion, TAVI often induces or worsens CDs, requiring PPM in more than one third of patients, although a trend in the recovery of CDs during the midterm was recorded. The independent predictors of PPM implantation were the depth of prosthesis implantation and pre-existing right bundle
引用
收藏
页码:747 / 754
页数:8
相关论文
共 17 条
[1]  
ACC/AHA/HRS, 2008, CIRCULATION, V117, pe350
[2]   Early Conduction Disorders Following Percutaneous Aortic Valve Replacement [J].
Calvi, Valeria ;
Puzzangara, Euglena ;
Pruiti, Giusi Paola ;
Conti, Sergio ;
Di Grazia, Angelo ;
Ussia, Gian Paolo ;
Capodanno, Davide ;
Tamburino, Corrado .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S126-S130
[3]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[4]   Hemiblocks revisited [J].
Elizari, Marcelo V. ;
Acunzo, Rafael S. ;
Ferreiro, Marcela .
CIRCULATION, 2007, 115 (09) :1154-1163
[5]   Expanding the Eligibility for Transcatheter Aortic Valve Implantation The Trans-Subclavian Retrograde Approach Using the III Generation CoreValve Revalving System [J].
Fraccaro, Chiara ;
Napodano, Massimo ;
Tarantini, Giuseppe ;
Gasparetto, Valeria ;
Gerosa, Gino ;
Bianco, Roberto ;
Bonato, Raffaele ;
Pittarello, Demetrio ;
Isabella, Giambattista ;
Iliceto, Sabino ;
Ramondo, Angelo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :828-833
[6]   Frequency of Conduction Disturbances After Transcatheter Implantation of an Edwards Sapien Aortic Valve Prosthesis [J].
Godin, Matthieu ;
Eltchaninoff, Helene ;
Furuta, Akira ;
Tron, Christophe ;
Anselme, Frederic ;
Bejar, Karim ;
Sanchez-Giron, Carlos ;
Bauer, Fabrice ;
Litzler, Pierre-Yves ;
Bessou, Jean-Paul ;
Cribier, Alain .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (05) :707-712
[7]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[8]   Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation [J].
Gutierrez, Marcos ;
Rodes-Cabau, Josep ;
Bagur, Rodrigo ;
Doyle, Daniel ;
DeLarochelliere, Robert ;
Bergeron, Sebastien ;
Lemieux, Jerome ;
Villeneuve, Jacques ;
Cote, Melanie ;
Bertrand, Olivier F. ;
Poirier, Paul ;
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Dumont, Eric .
AMERICAN HEART JOURNAL, 2009, 158 (02) :302-308
[9]   Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis [J].
Jilaihawi, Hasan ;
Chin, Derek ;
Vasa-Nicotera, Mariuca ;
Jeilan, Mohamed ;
Spyt, Tomasz ;
Ng, G. Andre ;
Bence, Johan ;
Logtens, Elaine ;
Kovac, Jan .
AMERICAN HEART JOURNAL, 2009, 157 (05) :860-866
[10]   Cause of Complete Atrioventricular Block After Percutaneous Aortic Valve Implantation Insights From a Necropsy Study [J].
Moreno, Raul ;
Dobarro, David ;
Lopez de Sa, Esteban ;
Prieto, Mario ;
Morales, Carmen ;
Calvo Orbe, Luis ;
Moreno-Gomez, Isidro ;
Filgueiras, David ;
Sanchez-Recalde, Angel ;
Galeote, Guillermo ;
Jimenez-Valero, Santiago ;
Lopez-Sendon, Jose-Luis .
CIRCULATION, 2009, 120 (05) :E29-E30