A comparison of full-field digital mammograms versus 2D synthesized mammograms for detection of microcalcifications on screening

被引:19
|
作者
Wahab, Rifat A. [1 ]
Lee, Su-Ju [1 ]
Zhang, Bin [2 ]
Sobel, Lawrence [1 ]
Mahoney, Mary C. [3 ]
机构
[1] Univ Cincinnati, Med Ctr, Dept Radiol, 234 Goodman St,ML 0772, Cincinnati, OH 45219 USA
[2] Cincinnati Childrens Hosp Med Ctr, Div Biostat & Epidemiol, 3333 Burnet Ave, Cincinnati, OH 45229 USA
[3] Univ Cincinnati, Med Ctr, Dept Radiol, 234 Goodman St,ML 0761, Cincinnati, OH 45267 USA
关键词
Screening mammogram; Synthetic 2D mammogram; Microcalcifications; RECONSTRUCTED PROJECTION IMAGES; BREAST TOMOSYNTHESIS DBT; DIAGNOSTIC PERFORMANCE; OBSERVER-PERFORMANCE; CANCER; COMBINATION; AGREEMENT; 2-VIEW;
D O I
10.1016/j.ejrad.2018.08.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare the observer agreement of microcalcification detection on synthetic 2D images to full field digital mammography (FFDM) at screening and determine if calcifications can be detected to the same degree and given the same BI-RADS assessment. Material and methods: Two-experienced radiologists retrospectively reviewed synthetic 2D images and FFDM, in separate sessions, to detect microcalcifications and provide a BIRADS assessment. A third experienced breast radiologist reviewed the cases that were disagreed upon and gave a final assessment. Between March 2016-December 2016, 414 women obtained a screening mammogram with tomosynthesis and acquisition of FFDM. 71 cases had combined FFDM and tomosynthesis images, calcifications visible on FFDM or no calcifications present, which comprised the study group. Synthetic 2D images were constructed from the DBT images. During session 1, all synthetic 2D images for the 71 cases were reviewed. During session 2, all the FFDM images for the 71 cases were reviewed. Tomosynthesis images were not reviewed. The agreement of detection of calcifications and BIRADS assessment between radiologists for FFDM and synthetic 2D images were assessed using Cohen's kappa test. Fisher's exact test was used to detect the differences in calcification identification among various breast densities on FFDM and synthetic 2D images. Results: For the detection of calcifications between synthetic 2D images and FFDM, there was moderate to substantial agreement (p-values < 0.0001) for the two radiologist. For the BIRADS assessments, the agreement between synthetic 2D imaging and FFDM was moderate (p-values < 0.0001). The inter-reader agreement for detection of calcifications was fair for using synthetic 2D and moderate for using FFDM (p-value < 0.0001). The final inter-reader agreement between FFDM and synthetic 2D images for the detection of calcifications was moderate (p-values < 0.0001) with the addition of the third reader. For the final BI-RADS assessment, there was moderate agreement between synthetic 2D imaging and FFDM (p-value < 0.0001). The two readers did not demonstrate a significant difference in the detection of microcalcifications for those who were dense or non-dense (p-value range 0.076-0.302). Conclusion: Radiologist interpreting synthetic 2D imaging and FFDM have similar frequency for detection of calcifications and BIRADS assessment. A synthetic 2D mammogram may be a sufficient replacement for FFDM at screening.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 50 条
  • [31] Comparison of Outcomes for One-View Asymmetries Recalled From Digital Breast Tomosynthesis Versus Full-Field Digital Mammography Screening Examinations
    Gong, Anna J.
    Nguyen, Derek L.
    Lee, Emerson E.
    Mullen, Lisa A.
    Myers, Kelly S.
    Oluyemi, Eniola
    Ambinder, Emily B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (05) : 724 - 733
  • [32] Women's features and inter-/intra-rater agreement on mammographic density assessment in full-field digital mammograms (DDM-SPAIN)
    Perez-Gomez, Beatriz
    Ruiz, Franciso
    Martinez, Inmaculada
    Casals, Maria
    Miranda, Josefa
    Sanchez-Contador, Carmen
    Vidal, Carmen
    Llobet, Rafael
    Pollan, Marina
    Salas, Dolores
    BREAST CANCER RESEARCH AND TREATMENT, 2012, 132 (01) : 287 - 295
  • [33] Comparison of two-dimensional synthesized mammogram (2DSM) and conventional full-field digital mammogram (FFDM) for evaluation of breast cancer
    Choi, Gayoung
    Woo, Ok Hee
    Shin, Hye Seon
    Jang, Seonah
    Cho, Kyu Ran
    Seo, Bo Kyoung
    CLINICAL IMAGING, 2017, 43 : 170 - 174
  • [34] Comparison of the Detection Rate of Simulated Microcalcifications in Full-Field Digital Mammography, Digital Breast Tomosynthesis, and Synthetically Reconstructed 2-Dimensional Images Performed With 2 Different Digital X-ray Mammography Systems
    Peters, Sabine
    Hellmich, Martin
    Stork, Alexander
    Kemper, Joern
    Grinstein, Olga
    Puesken, Michael
    Stahlhut, Leandra
    Kinner, Sonja
    Maintz, David
    Krug, Kathrin Barbara
    INVESTIGATIVE RADIOLOGY, 2017, 52 (04) : 206 - 215
  • [35] Women’s features and inter-/intra-rater agreement on mammographic density assessment in full-field digital mammograms (DDM-SPAIN)
    Beatriz Pérez-Gómez
    Franciso Ruiz
    Inmaculada Martínez
    María Casals
    Josefa Miranda
    Carmen Sánchez-Contador
    Carmen Vidal
    Rafael Llobet
    Marina Pollán
    Dolores Salas
    Breast Cancer Research and Treatment, 2012, 132 : 287 - 295
  • [36] Comparison of the diagnostic performance of synthesized two-dimensional mammography and full-field digital mammography alone or in combination with digital breast tomosynthesis
    Chao You
    Yunyan Zhang
    Yajia Gu
    Qin Xiao
    Guangyu Liu
    Xigang Shen
    Wentao Yang
    Weijun Peng
    Breast Cancer, 2020, 27 : 47 - 53
  • [37] Recurrent attention U-Net for segmentation and quanti fi cation of breast arterial calci fi cations on synthesized 2D mammograms
    Aljabri, Manar
    Alghamdi, Manal
    Collado-Mesa, Fernando
    Abdel-Mottaleb, Mohamed
    PEERJ COMPUTER SCIENCE, 2024, 10
  • [38] Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images
    Skaane, Per
    Bandos, Andriy I.
    Eben, Ellen B.
    Jebsen, Ingvild N.
    Krager, Mona
    Haakenaasen, Unni
    Ekseth, Ulrika
    Izadi, Mina
    Hofvind, Solveig
    Gullien, Randi
    RADIOLOGY, 2014, 271 (03) : 655 - 663
  • [39] Pilot Study on the Detection of Simulated Lesions Using a 2D and 3D Digital Full-Field Mammography System with a Newly Developed High Resolution Detector Based on Two Shifts of a-Se
    Schulz-Wendtland, R.
    Bani, M.
    Lux, M. P.
    Schwab, S.
    Loehberg, C. R.
    Jud, S. M.
    Rauh, C.
    Bayer, C. M.
    Beckmann, M. W.
    Uder, M.
    Fasching, P. A.
    Adamietz, B.
    Meier-Meitinger, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2012, 72 (05) : 408 - 411
  • [40] Comparison between two-dimensional synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for the detection of T1 breast cancer
    Choi, Ji Soo
    Han, Boo-Kyung
    Ko, Eun Young
    Ko, Eun Sook
    Hahn, Soo Yeon
    Shin, Jung Hee
    Kim, Min Jung
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2538 - 2546