A comparison of full-field digital mammograms versus 2D synthesized mammograms for detection of microcalcifications on screening

被引:19
|
作者
Wahab, Rifat A. [1 ]
Lee, Su-Ju [1 ]
Zhang, Bin [2 ]
Sobel, Lawrence [1 ]
Mahoney, Mary C. [3 ]
机构
[1] Univ Cincinnati, Med Ctr, Dept Radiol, 234 Goodman St,ML 0772, Cincinnati, OH 45219 USA
[2] Cincinnati Childrens Hosp Med Ctr, Div Biostat & Epidemiol, 3333 Burnet Ave, Cincinnati, OH 45229 USA
[3] Univ Cincinnati, Med Ctr, Dept Radiol, 234 Goodman St,ML 0761, Cincinnati, OH 45267 USA
关键词
Screening mammogram; Synthetic 2D mammogram; Microcalcifications; RECONSTRUCTED PROJECTION IMAGES; BREAST TOMOSYNTHESIS DBT; DIAGNOSTIC PERFORMANCE; OBSERVER-PERFORMANCE; CANCER; COMBINATION; AGREEMENT; 2-VIEW;
D O I
10.1016/j.ejrad.2018.08.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare the observer agreement of microcalcification detection on synthetic 2D images to full field digital mammography (FFDM) at screening and determine if calcifications can be detected to the same degree and given the same BI-RADS assessment. Material and methods: Two-experienced radiologists retrospectively reviewed synthetic 2D images and FFDM, in separate sessions, to detect microcalcifications and provide a BIRADS assessment. A third experienced breast radiologist reviewed the cases that were disagreed upon and gave a final assessment. Between March 2016-December 2016, 414 women obtained a screening mammogram with tomosynthesis and acquisition of FFDM. 71 cases had combined FFDM and tomosynthesis images, calcifications visible on FFDM or no calcifications present, which comprised the study group. Synthetic 2D images were constructed from the DBT images. During session 1, all synthetic 2D images for the 71 cases were reviewed. During session 2, all the FFDM images for the 71 cases were reviewed. Tomosynthesis images were not reviewed. The agreement of detection of calcifications and BIRADS assessment between radiologists for FFDM and synthetic 2D images were assessed using Cohen's kappa test. Fisher's exact test was used to detect the differences in calcification identification among various breast densities on FFDM and synthetic 2D images. Results: For the detection of calcifications between synthetic 2D images and FFDM, there was moderate to substantial agreement (p-values < 0.0001) for the two radiologist. For the BIRADS assessments, the agreement between synthetic 2D imaging and FFDM was moderate (p-values < 0.0001). The inter-reader agreement for detection of calcifications was fair for using synthetic 2D and moderate for using FFDM (p-value < 0.0001). The final inter-reader agreement between FFDM and synthetic 2D images for the detection of calcifications was moderate (p-values < 0.0001) with the addition of the third reader. For the final BI-RADS assessment, there was moderate agreement between synthetic 2D imaging and FFDM (p-value < 0.0001). The two readers did not demonstrate a significant difference in the detection of microcalcifications for those who were dense or non-dense (p-value range 0.076-0.302). Conclusion: Radiologist interpreting synthetic 2D imaging and FFDM have similar frequency for detection of calcifications and BIRADS assessment. A synthetic 2D mammogram may be a sufficient replacement for FFDM at screening.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 50 条
  • [21] Comparison of two-dimensional synthesized mammograms versus original digital mammograms: a quantitative assessment
    Maxine Tan
    Mundher Al-Shabi
    Wai Yee Chan
    Leya Thomas
    Kartini Rahmat
    Kwan Hoong Ng
    Medical & Biological Engineering & Computing, 2021, 59 : 355 - 367
  • [22] Comparison of two-dimensional synthesized mammograms versus original digital mammograms: a quantitative assessment
    Tan, Maxine
    Al-Shabi, Mundher
    Chan, Wai Yee
    Thomas, Leya
    Rahmat, Kartini
    Ng, Kwan Hoong
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (02) : 355 - 367
  • [23] Volumetric breast density estimation from full-field digital mammograms
    van Engeland, S
    Snoeren, PR
    Huisman, H
    Boetes, C
    Karssemeijer, N
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (03) : 273 - 282
  • [24] Detection of Microcalcifications on Digital Screening Mammograms Using Varying Degrees of Monitor Zooming
    Haygood, Tamara Miner
    Arribas, Elsa
    Liu, Qing Mary Ashley
    Atkinson, E. Neely
    Brennan, Patrick C.
    Santiago, Lumarie
    Carkaci, Selin
    Lane, Deanna
    Stephens, Tanya W.
    LePetross, Huong
    Adrada, Beatriz
    Davis, Paul
    Whitman, Gary J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) : W761 - W768
  • [25] Image quality of a wet laser printer versus a paper printer for full-field digital mammograms
    Schueller, G
    Kaindl, E
    Matzek, WK
    Semturs, F
    Schueller-Weidekamm, C
    Helbich, TH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (01) : 38 - 43
  • [26] Screening mammography detected cancers: Sensitivity of a computer-aided detection system applied to full-field digital mammograms
    Yang, Sang Kyu
    Moon, Woo Kyung
    Cho, Nariya
    Park, Jeong Seon
    Cha, Joo Hee
    Kim, Sun Mi
    Kim, Seung Ja
    Im, Jung-Gi
    RADIOLOGY, 2007, 244 (01) : 104 - 111
  • [27] Microcalcification detection in full-field digital mammograms: A fully automated computer-aided system
    Basile, T. M. A.
    Fanizzi, A.
    Losurdo, L.
    Bellotti, R.
    Bottigli, U.
    Dentamaro, R.
    Didonna, V
    Fausto, A.
    Massafra, R.
    Moschetta, M.
    Tamborra, P.
    Tangaro, S.
    La Forgia, D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 1 - 9
  • [28] Computer-aided detection of clustered microcalcifications on full-field digital mammograms: A two-view information fusion scheme for FP reduction
    Ge, Jun
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Helvie, Mark A.
    Zhou, Chuan
    Wei, Jun
    Zhang, Yiheng
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [29] Comparison of Tilt Correction Methods in Full Field Digital Mammograms
    Kallenberg, Michiel
    Karssemeijer, Nico
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 191 - 196
  • [30] Deep learning for mass detection in Full Field Digital Mammograms
    Agarwal, Richa
    Diaz, Oliver
    Yap, Moi Hoon
    Llado, Xavier
    Marti, Robert
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 121