A comparison of full-field digital mammograms versus 2D synthesized mammograms for detection of microcalcifications on screening

被引:19
|
作者
Wahab, Rifat A. [1 ]
Lee, Su-Ju [1 ]
Zhang, Bin [2 ]
Sobel, Lawrence [1 ]
Mahoney, Mary C. [3 ]
机构
[1] Univ Cincinnati, Med Ctr, Dept Radiol, 234 Goodman St,ML 0772, Cincinnati, OH 45219 USA
[2] Cincinnati Childrens Hosp Med Ctr, Div Biostat & Epidemiol, 3333 Burnet Ave, Cincinnati, OH 45229 USA
[3] Univ Cincinnati, Med Ctr, Dept Radiol, 234 Goodman St,ML 0761, Cincinnati, OH 45267 USA
关键词
Screening mammogram; Synthetic 2D mammogram; Microcalcifications; RECONSTRUCTED PROJECTION IMAGES; BREAST TOMOSYNTHESIS DBT; DIAGNOSTIC PERFORMANCE; OBSERVER-PERFORMANCE; CANCER; COMBINATION; AGREEMENT; 2-VIEW;
D O I
10.1016/j.ejrad.2018.08.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare the observer agreement of microcalcification detection on synthetic 2D images to full field digital mammography (FFDM) at screening and determine if calcifications can be detected to the same degree and given the same BI-RADS assessment. Material and methods: Two-experienced radiologists retrospectively reviewed synthetic 2D images and FFDM, in separate sessions, to detect microcalcifications and provide a BIRADS assessment. A third experienced breast radiologist reviewed the cases that were disagreed upon and gave a final assessment. Between March 2016-December 2016, 414 women obtained a screening mammogram with tomosynthesis and acquisition of FFDM. 71 cases had combined FFDM and tomosynthesis images, calcifications visible on FFDM or no calcifications present, which comprised the study group. Synthetic 2D images were constructed from the DBT images. During session 1, all synthetic 2D images for the 71 cases were reviewed. During session 2, all the FFDM images for the 71 cases were reviewed. Tomosynthesis images were not reviewed. The agreement of detection of calcifications and BIRADS assessment between radiologists for FFDM and synthetic 2D images were assessed using Cohen's kappa test. Fisher's exact test was used to detect the differences in calcification identification among various breast densities on FFDM and synthetic 2D images. Results: For the detection of calcifications between synthetic 2D images and FFDM, there was moderate to substantial agreement (p-values < 0.0001) for the two radiologist. For the BIRADS assessments, the agreement between synthetic 2D imaging and FFDM was moderate (p-values < 0.0001). The inter-reader agreement for detection of calcifications was fair for using synthetic 2D and moderate for using FFDM (p-value < 0.0001). The final inter-reader agreement between FFDM and synthetic 2D images for the detection of calcifications was moderate (p-values < 0.0001) with the addition of the third reader. For the final BI-RADS assessment, there was moderate agreement between synthetic 2D imaging and FFDM (p-value < 0.0001). The two readers did not demonstrate a significant difference in the detection of microcalcifications for those who were dense or non-dense (p-value range 0.076-0.302). Conclusion: Radiologist interpreting synthetic 2D imaging and FFDM have similar frequency for detection of calcifications and BIRADS assessment. A synthetic 2D mammogram may be a sufficient replacement for FFDM at screening.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 50 条
  • [1] Hough Transform for Clustered Microcalcifications Detection in Full-Field Digital Mammograms
    Fanizzi, A.
    Basile, T. M. A.
    Losurdo, L.
    Amoroso, N.
    Bellotti, R.
    Bottigli, U.
    Dentamaro, R.
    Didonna, V.
    Fausto, A.
    Massafra, R.
    Moschetta, M.
    Tamborra, P.
    Tangaro, S.
    La Forgia, D.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XL, 2017, 10396
  • [2] Computer-aided detection system for clustered microcalcifications: comparison of performance on full-field digital mammograms and digitized screen-film mammograms
    Ge, Jun
    Hadjiiski, Lubomir M.
    Sahiner, Berkman
    Wei, Jun
    Helvie, Mark A.
    Zhou, Chuan
    Chan, Heang-Ping
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (04): : 981 - 1000
  • [3] Computer aided detection of clusters of microcalcifications on full field digital mammograms
    Ge, Jun
    Sahiner, Berkman
    Hadjiiski, Lubomir M.
    Chan, Heang-Ping
    Wei, Jun
    Helvie, Mark A.
    Zhou, Chuan
    MEDICAL PHYSICS, 2006, 33 (08) : 2975 - 2988
  • [4] Quantitative comparison of clustered microcalcifications in for-presentation and for-processing mammograms in full-field digital mammography
    Wang, Juan
    Nishikawa, Robert M.
    Yang, Yongyi
    MEDICAL PHYSICS, 2017, 44 (07) : 3726 - 3738
  • [5] Monitor Zooming and Detection of Microcalcifications on Digital Screening Mammograms
    Haygood, T.
    Arribas, E.
    Liu, Q.
    Brennan, P.
    Santiago, L.
    Carkaci, S.
    Lane, D.
    Whitman, G.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [6] Computerized detection and classification of malignant and benign microcalcifications on full field digital mammograms
    Hadjiiski, Lubonnir
    Filev, Peter
    Chan, Heang-Ping
    Ge, Jun
    Sahiner, Berkman
    Helvie, Mark A.
    Rolibidoux, Marilyn A.
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 336 - 342
  • [7] Automatic Dual-View Mass Detection in Full-Field Digital Mammograms
    Amit, Guy
    Hashoul, Sharbell
    Kisilev, Pavel
    Ophir, Boaz
    Walach, Eugene
    Zlotnick, Aviad
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 44 - 52
  • [8] Comparison of full field digital and analog mammograms
    van Woudenberg, S
    Roelofs, T
    Hendriks, J
    Karssemeijer, N
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 497 - 501
  • [9] YOLO Based Breast Masses Detection and Classification in Full-Field Digital Mammograms
    Aly, Ghada Hamed
    Marey, Mohammed
    El-Sayed, Safaa Amin
    Tolba, Mohamed Fahmy
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 200 (200)
  • [10] Computer-aided detection system applied to full-field digital mammograms
    Vega Bolivar, Alfonso
    Sanchez Gomez, Sonia
    Merino, Paula
    Alonso-Bartolome, Pilar
    Ortega Garcia, Estrella
    Munoz Cacho, Pedro
    Hoffmeister, Jeffrey W.
    ACTA RADIOLOGICA, 2010, 51 (10) : 1086 - 1092