Frequency-phase shift correction of interlaced lissajous trajectories for precise imaging in endoscopic scanning microscopy

被引:5
作者
Leong, Yang Sing [1 ]
Mokhtar, Mohd Hadri Hafiz [1 ]
Zukhri, Amirul Asyraf [1 ]
Zan, Mohd Saiful Dzulkefly [1 ]
Arsad, Norhana [1 ]
Reaz, Mamun B. I. [1 ]
Bakar, Ahmad Ashrif A. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Photon Technol Lab, Dept Elect Elect & Syst, Gen Off,Fac Engn & Built Environm, Bangi 43600, Selangor, Malaysia
关键词
Lissajousscan; Opticalimaging; CantileverVibration; Phaseerror; Endoscopicscanner; FIBER SCANNER;
D O I
10.1016/j.optlaseng.2022.107177
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Endoscopic scanners with a resonant scanning fibre cantilever have gained popularity in the biomedical field as optical imaging tools. However, precise characterisation of fibre cantilever-based scanners remains challenging, as the system is susceptible to dynamic discrepancies. To date, discussions regarding the dynamical influence of frequency and phase shift on reconstructed images in the Lissajous scanning system are limited. By looking into the theory behind the dynamic discrepancies, we have formulated mathematical expressions that describe the behaviour of frequency and phase shift on the frequency and phase response of the resonant scanning system. Phase drift occurs as a result of a mismatch between the driving signal and the resonance frequency, which modifies both the actual phase response and the Lissajous trajectory. The Lissajous trajectory shifts as a function of dynamical phase shift and slope. As a result, the coordinate for the Lissajous trajectory shifts in both vertical and horizontal coordinates, thereby causing image distortion and interlacing artifacts during image reconstruction. We verify the mathematical formulation by simulation and experimental confocal imaging of target samples with distinct features. A frequency shift of 0.1 Hz is sufficient to produce the interlacing artifacts. Our results establish that an accurate phase control in the Lissajous scanning system is required for clear, precise reconstructed images. The findings can be extended to non-resonant scanning systems and other scanning patterns. With the phase kept under control, any dynamical issues with a handheld endoscopic scanner can be mitigated to ensure distortion -free image reconstruction. More importantly, the main outcome of this study has proven the ability to reconstruct images precisely on target samples of various feature sizes without any interlacing effect.
引用
收藏
页数:10
相关论文
共 56 条
  • [11] Handheld endomicroscope using a fiber-optic harmonograph enables real-time and in vivo confocal imaging of living cell morphology and capillary perfusion
    Hwang, Kyungmin
    Seo, Yeong-Hyeon
    Kim, Daniel Y.
    Ahn, Jinhyo
    Lee, Soyoung
    Han, Kyung Hee
    Lee, Koun-Hee
    Jon, Sangyong
    Kim, Pilhan
    Yu, Kate E.
    Kim, Hyungsin
    Kang, Shin-Hyuk
    Jeong, Ki-Hun
    [J]. MICROSYSTEMS & NANOENGINEERING, 2020, 6 (01)
  • [12] Frequency selection rule for high definition and high frame rate Lissajous scanning
    Hwang, Kyungmin
    Seo, Yeong-Hyeon
    Ahn, Jinhyo
    Kim, Pilhan
    Jeong, Ki-Hun
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [13] An Electro-Thermally Actuated Micro-Cantilever-Based Fiber Optic Scanner
    Kaur, Mandeep
    Brown, Malcolm
    Lane, Pierre M.
    Menon, Carlo
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (17) : 9877 - 9885
  • [14] Review of diverse optical fibers used in biomedical research and clinical practice
    Keiser, Gerd
    Xiong, Fei
    Cui, Ying
    Shum, Perry Ping
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (08)
  • [15] Unwarped Lissajous Scanning With Polarization Maintaining Fibers
    Khayatzadeh, Ramin
    Ferhanoglu, Onur
    Civitci, Fehmi
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2017, 29 (19) : 1623 - 1626
  • [16] Lissajous Scanning Two-photon Endomicroscope for In vivo Tissue Imaging
    Kim, Daniel Youngsuk
    Hwang, Kyungmin
    Ahn, Jinhyo
    Seo, Yeong-Hyeon
    Kim, Jae-Beom
    Lee, Soyoung
    Yoon, Jin-Hui
    Kong, Eunji
    Jeong, Yong
    Jon, Sangyong
    Kim, Pilhan
    Jeong, Ki-Hun
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [17] Objective-lens-free confocal endomicroscope using Lissajous scanning lensed-fiber
    Kim, Jae-Beom
    Jeon, Jaehun
    Hwang, Kyungmin
    Kim, Daniel Y.
    Jeong, Ki-Hun
    [J]. JOURNAL OF OPTICAL MICROSYSTEMS, 2021, 1 (03):
  • [18] High performance open loop control of scanning with a small cylindrical cantilever beam
    Kundrat, Matthew J.
    Reinhall, Per G.
    Lee, Cameron M.
    Seibel, Eric J.
    [J]. JOURNAL OF SOUND AND VIBRATION, 2011, 330 (08) : 1762 - 1771
  • [19] Monostatic all-fiber scanning LADAR system
    Leach, Jeffrey H.
    Chinn, Stephen R.
    Goldberg, Lew
    [J]. APPLIED OPTICS, 2015, 54 (33) : 9752 - 9757
  • [20] Scanning fiber endoscopy with highly flexible, 1 mm catheterscopes for wide-field, full-color imaging
    Lee, Cameron M.
    Engelbrecht, Christoph J.
    Soper, Timothy D.
    Helmchen, Fritjof
    Seibel, Eric J.
    [J]. JOURNAL OF BIOPHOTONICS, 2010, 3 (5-6) : 385 - 407