Determination of thimerosal in human and veterinarian vaccines by photochemical vapor generation coupled to ICP OES

被引:38
作者
dos Santos, Eder Jose [1 ]
Herrmann, Amanda Beatriz [1 ]
dos Santos, Arlene Bispo [1 ]
Baika, Loana Mara [1 ]
Sato, Charyane Satie [1 ]
Tormen, Luciano [2 ]
Sturgeon, Ralph Edward [3 ]
Curtius, Adilson Jose [2 ]
机构
[1] TECPAR, Inst Tecnol Parana, BR-81350010 Curitiba, Parana, Brazil
[2] Univ Fed Santa Catarina, Dept Quim, BR-88040090 Florianopolis, SC, Brazil
[3] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R9, Canada
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; SINGLE-DROP MICROEXTRACTION; SAMPLE INTRODUCTION; INORGANIC SELENIUM; FLUORESCENCE SPECTROMETRY; EMISSION-SPECTROMETRY; OPHTHALMIC SOLUTIONS; HYDRIDE GENERATION; BIOLOGICAL SAMPLES;
D O I
10.1039/c0ja00029a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and fast method is described for the determination of Hg, present as thimerosal, in vaccines by photochemical vapor generation coupled to axial view inductively coupled plasma optical emission spectrometry. Mercury emission was detected at 253.652 nm. No sample treatment was necessary other than simple dilution and addition of 10% v/v formic acid. Vapor generation conditions were optimized and included formic acid concentration, sample flow rate, reactor tube dimensions and argon flow rate. External calibration was achieved using aqueous standard solutions of Hg(2+) containing 10% v/v formic acid. The detection limit (3 s, n = 10) was 0.3 mu g L(-1) of Hg or 0.6 mu g L(-1) of thimerosal in solution, equivalent to 60.0 mu g L(-1) of thimerosal in the original vaccine solution or 0.03 mu g of thimerosal per dose. The procedure was applied to the analysis of anti-rabies, diphtheria/tetanus, hepatitis B and influenza vaccines, sourced from two producers. Thimerosal was present in the vaccines within a narrow range of 47.4 +/- 0.4 to 53.7 +/- 0.7 mu g per dose (0.5 mL vaccine), in agreement with product information, except for the influenza vaccine from one of the producers, for which the thimerosal mass per dose was below the detection limit. Recoveries of 93-102% demonstrated the robustness of the methodology. Precision, expressed as relative standard deviation, yielded 2.9% under conditions of repeatability and 4.4% for reproducibility. This simple procedure is currently adopted by Tecpar (Curitiba, Brazil) to control the amount of thimerosal in anti-rabies vaccines.
引用
收藏
页码:1627 / 1632
页数:6
相关论文
共 39 条
[1]  
AGAKI H, 1973, CHEMOSPHERE, V2, P131
[2]   PHOTOCHEMICAL TRANSFORMATION OF MERCURIC SULFIDE INTO METHYLMERCURY IN AQUEOUS-SOLUTIONS [J].
AKAGI, H ;
FUJITA, Y ;
TAKABATAKE, E .
CHEMISTRY LETTERS, 1976, (01) :1-4
[3]  
Alexiu V, 2004, ACTA CHIM SLOV, V51, P361
[4]   Flow injection analysis of mercury(II) in pharmaceuticals based on enzyme inhibition and biosensor detection [J].
Bertocchi, P ;
Ciranni, E ;
Compagnone, D ;
Magearu, V ;
Palleschi, G ;
Pirvutoiu, S ;
Valvo, L .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :263-269
[5]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[6]   Simultaneous spectrophotometric-multivariate calibration determination of several components of ophthalmic solutions: phenylephrine, chloramphenicol, antipyrine, methylparaben and thimerosal [J].
Collado, MS ;
Mantovani, VE ;
Goicoechea, HC ;
Olivieri, AC .
TALANTA, 2000, 52 (05) :909-920
[7]   Photoassisted vapor generation in the presence of organic acids for ultrasensitive determination of Se by electrothermal-atomic absorption. spectrometry following headspace single-drop microextraction [J].
Figueroa, R ;
García, M ;
Lavilla, I ;
Bendicho, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (12) :1556-1563
[8]   Hydride generation-headspace single-drop microextraction-electrothermal atomic absorption spectrometry method for determination of selenium in waters after photoassisted prereduction [J].
Fragueiro, S ;
Lavilla, I ;
Bendicho, C .
TALANTA, 2006, 68 (04) :1096-1101
[9]   On-line photoassisted vapour generation implemented in an automated flow-injection/stopped-flow manifold coupled to an atomic detector for determination of selenium [J].
Garcia, M. ;
Figueroa, R. ;
Lavilla, I. ;
Bendicho, C. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (06) :582-587
[10]   Neurodevelopmental disorders following thimerosal-containing childhood immunizations: A follow-up analysis [J].
Geier, DA ;
Geier, MR .
INTERNATIONAL JOURNAL OF TOXICOLOGY, 2004, 23 (06) :369-376