Improved indoor air temperature and humidity control using a novel direct-expansion-based air conditioning system

被引:12
作者
Yang, Liu [1 ]
Deng, Shiming [1 ]
Fang, Guanyu [1 ]
Li, Weilin [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
[2] Zhengzhou Univ, Sch Civil Engn, Sci Ave 100, Zhengzhou 450001, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 43卷
关键词
Direct expansion; Air conditioning; Two sectioned cooling coil; Controllability test; Humidity control; OPERATIONAL CHARACTERISTICS; CAPACITY CONTROLLER; CONTROL ALGORITHMS; PERFORMANCE; EQUIPMENT;
D O I
10.1016/j.jobe.2021.102920
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many approaches have been tried to obtain an improved indoor thermal environment in small-to medium-sized buildings located in hot-humid climates when using direct-expansion (DX)-based air conditioning (A/C) systems. However, inadequacies still existed in these approaches. Therefore, to address these problems, a novel DX-based A/C system with a two sectioned cooling coil (TS-DXAC) has been proposed. In this paper, a control strategy to operate the TS-DXAC system for achieving an improved indoor air temperature and humidity control in hot and humid climates is presented. Firstly, the detailed configurations of the TS-DXAC system and the control strategy of the TS-DXAC system are presented. The developed strategy included two control algorithms, i.e., Algorithm I and Algorithm II, enabling the TS-DXAC system to be operated under two different indoor conditions, i.e., hot-humid, and hot-dry, respectively. Secondly, a test TS-DXAC system was set up and the controllability tests for the control strategy were carried out. This is followed by presenting the experimental results and related discussions. The experimental results demonstrated that in all the tests, indoor air temperature could be directly controlled at the two indoor conditions, while indoor air temperature and relative humidity could be simultaneously controlled over a relatively long period at a hot-humid indoor condition using Algorithm I. The control strategy enabled the TS-DXAC system to respond the changes in either indoor settings or cooling loads by outputting variable sensible and latent cooling capacities at a higher energy efficiency compared to conventional On-Off controlled DX A/C systems. However, to improve the control sensitivity under Algorithm I, consideration should be given to the variable speed operation of the compressor in the TS-DXAC system.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Development of a superheat controller for mitigating hunting in a direct expansion air conditioning system
    Xia, Yudong
    Ding, Qiang
    Jiang, Zhoushu
    Deng, Shiming
    Song, Mengjie
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2085 - 2091
  • [42] Improved control strategies in air-conditioning system
    Kotaki, Masakazu
    Yamakawa, Yuji
    Yamazaki, Takanori
    Matsuba, Tadahiko
    Kamimura, Kazuyuki
    Kurosu, Shigeru
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 3323 - +
  • [43] Further development of a thermal comfort based fuzzy logic controller for a direct expansion air conditioning system
    Yan, Huaxia
    Pan, Yan
    Li, Zhao
    Deng, Shiming
    APPLIED ENERGY, 2018, 219 : 312 - 324
  • [44] Adaptability of a temperature and humidity independent control air- conditioning system in green office buildings
    Niu, Runping
    Fan, Yingying
    Geng, Lizhi
    JOURNAL OF BUILDING ENGINEERING, 2021, 42
  • [45] The application of feedforward control in a direct expansion (DX) air conditioning plant
    Deng, SM
    BUILDING AND ENVIRONMENT, 2002, 37 (01) : 35 - 40
  • [46] Transient simulation of a Dual-evaporator air conditioning system for developing an improved humidity control strategy
    Yan, Huaxia
    Deng, Shiming
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1832 - 1837
  • [47] A novel neural network aided fuzzy logic controller for a variable speed (VS) direct expansion (DX) air conditioning (A/C) system
    Li, Zhao
    Xu, Xiangguo
    Deng, Shiming
    Pan, Dongmei
    APPLIED THERMAL ENGINEERING, 2015, 78 : 9 - 23
  • [48] Indoor thermal comfort characteristics under the control of a direct expansion air conditioning unit having a variable-speed compressor and a supply air fan
    Deng Shiming
    Li Zheng
    Qu Minglu
    APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) : 2187 - 2193
  • [49] Dynamic modeling of room temperature and thermodynamic efficiency for direct expansion air conditioning systems using Bayesian neural network
    Sholahudin
    Ohno, Keisuke
    Giannetti, Niccolo
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    APPLIED THERMAL ENGINEERING, 2019, 158
  • [50] An experimental study on the operational characteristics of a direct expansion based enhanced dehumidification air conditioning system
    Chen, Wenjing
    Chan, Ming-yin
    Weng, Wenbing
    Yan, Huaxia
    Deng, Shiming
    APPLIED ENERGY, 2018, 225 : 922 - 933