Engineering of CuO/ZrO2 nanocomposite-based electrochemical sensor for the selective detection of hydrogen peroxide

被引:12
作者
Manjushree, S. G. [1 ]
Adarakatti, Prashanth S. [2 ]
Udayakumar, Velu [1 ,2 ,3 ]
机构
[1] Siddaganga Inst Technol, Dept Chem, Tumkur 572102, India
[2] SVM Arts Sci & Commerce Coll, Dept Chem, Ilkal 587125, India
[3] MVJ Coll Engn, Dept Chem, Bangalore 560067, Karnataka, India
关键词
Electrochemical sensor; Copper oxide; Zirconia; H2O2; Cyclic voltammetry; Amperometry; GRAPHITE COMPOSITE ELECTRODES; COPPER-OXIDE NANOSTRUCTURES; NANOPARTICLES; PERFORMANCE; CATALYSTS; ZIRCONIA; FILM; CU;
D O I
10.1007/s11581-021-04243-2
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
For the first time, non-enzymatic hydrogen peroxide (H2O2) electrochemical sensor based on copper oxide/zirconia nanocomposite (CuO/ZrO2 nanocomposite) has been designed and constructed. In the present study, simple hydrothermal methods were used to synthesize the materials followed by calcination process. The structural and morphological properties of the prepared nanocomposites were investigated by using various analytical and spectroscopic techniques, namely, TEM, FE-SEM-EDAX, XPS, XRD, and BET surface area. In addition, the electrochemical properties were explored by using electrochemical tool such as cyclic voltammetry and amperometric techniques. The obtained results clearly demonstrated that the prepared material hold excellent-crystallinity, well-defined honeycomb-like framework and exhibited an improved analytical performance in the form of current towards the detection of H2O2 due to the presence of ZrO2 which could prevent the agglomeration of duel oxidation state of copper oxide nanoparticles and improved the electrocatalytic performance of copper oxide. Furthermore, the ZrO2's ionic electrical conductivity can aid faster electron transfer at the modified electrode. The proposed electrochemical sensor exhibited a wide working linear range of 50-800 mu M, good sensitivity of 0.28 mu A mu M-1 cm(-2), and lower detection limit 14.5 mu M (S/N = 3). Also in the presence of biologically co-interfering compounds such as glucose, dopamine, ascorbic acid, and uric acid, the proposed sensor had an exceptional selectivity.
引用
收藏
页码:5309 / 5322
页数:14
相关论文
共 47 条
  • [1] Influence of thermal annealing on microstructural, morphological, optical properties and surface electronic structure of copper oxide thin films
    Akgul, Funda Aksoy
    Akgul, Guvenc
    Yildirim, Nurcan
    Unalan, Husnu Emrah
    Turan, Rasit
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2014, 147 (03) : 987 - 995
  • [2] Study of Copper Doped Zirconium Dioxide Nanoparticles Synthesized via Sol-Gel Technique for Photocatalytic Applications
    Arjun, A.
    Dharr, Ashwati
    Raguram, T.
    Rajni, K. S.
    [J]. JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2020, 30 (12) : 4989 - 4998
  • [3] Direct electrochemistry of hemoglobin and biosensing for hydrogen peroxide using a film containing silver nanoparticles and poly(amidoamine) dendrimer
    Baccarin, Marina
    Janegitz, Bruno C.
    Berte, Rodrigo
    Vicentini, Fernando Campanha
    Banks, Craig E.
    Fatibello-Filho, Orlando
    Zucolotto, Valtencir
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 97 - 102
  • [4] Sonochemical synthesis of gum guar biopolymer stabilized copper oxide on exfoliated graphite: Application for enhanced electrochemical detection of H2O2 in milk and pharmaceutical samples
    Balu, Sridharan
    Palanisamy, Selvakumar
    Velusamy, Vijaylakshmi
    Yang, Thomas C. K.
    [J]. ULTRASONICS SONOCHEMISTRY, 2019, 56 : 254 - 263
  • [5] A sensitive nonenzymatic hydrogen peroxide sensor using cadmium oxide nanoparticles/multiwall carbon nanotube modified glassy carbon electrode
    Butwong, Nutthaya
    Zhou, Lin
    Ng-Eontae, Wittaya
    Burakham, Rodjana
    Moore, Eric
    Srijaranai, Supalax
    Luong, John H. T.
    Glennon, Jeremy D.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 41 - 46
  • [6] Glucose and hydrogen peroxide dual-mode electrochemical sensing using hydrothermally grown CuO nanorods
    Chakraborty, Pinak
    Dhara, Saurab
    Debnath, Kamalesh
    Mondal, Suvra Prakash
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 833 : 213 - 220
  • [7] DIAGNOSTIC SPECTRA FOR XPS ANALYSIS OF CU-O-S-H COMPOUNDS
    CHAWLA, SK
    SANKARRAMAN, N
    PAYER, JH
    [J]. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1992, 61 (01) : 1 - 18
  • [8] Interaction between Amorphous Zirconia Nanoparticles and Graphite: Electrochemical Applications for Gallic Acid Sensing Using Carbon Paste Electrodes in Wine
    Chikere, Chrys. O.
    Faisal, Nadimul Haque
    Kong-Thoo-Lin, Paul
    Fernandez, Carlos
    [J]. NANOMATERIALS, 2020, 10 (03)
  • [9] Electrospun CuO-ZnO nanohybrid: Tuning the nanostructure for improved amperometric detection of hydrogen peroxide as a non-enzymatic sensor
    Daemi, Sahar
    Ghasemi, Shahram
    Ashkarran, Ali Akbar
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2019, 550 : 180 - 189
  • [10] Electrochemical Sensor Based on Prussian Blue Electrochemically Deposited at ZrO2Doped Carbon Nanotubes Glassy Carbon Modified Electrode
    Danny Jerez-Masaquiza, Marlon
    Fernandez, Lenys
    Gonzalez, Gema
    Montero-Jimenez, Marjorie
    Espinoza-Montero, Patricio J.
    [J]. NANOMATERIALS, 2020, 10 (07) : 1 - 21