Influence of single versus multiple actuations on the particle size distribution of beclometasone dipropionate metered-dose inhalers

被引:3
作者
Feddah, MR [1 ]
Davies, NM [1 ]
机构
[1] Univ Sydney, Fac Pharm, Sydney, NSW, Australia
关键词
D O I
10.1211/0022357021549
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The particle size distributions of beclometasone dipropionate delivered from Becotide and Respocort inhalers after single and multiple actuations were investigated using the Andersen Mark 11 Cascade impactor and the drug was quantified using high performance liquid chromatography. The fine particle mass and the mass median aerodynamic diameter were calculated. An apparent increase in mass median aerodynamic diameter was observed when the number of actuations increased. In addition, the fine particle mass decreased as the number of actuations increased. When performing and analysing cascade impaction study data differences between single versus multiple actuations must be considered. Regulatory guidelines should be amended to stipulate the number of actuations to be loaded into devices used to evaluate the particle size distribution of inhaled aerosol products.
引用
收藏
页码:1055 / 1061
页数:7
相关论文
共 18 条
[1]   Comparison of aerodynamic particle size from 250 mu g per dose beclomethasone dipropionate metered-dose inhalers [J].
Barnes, AR ;
Nash, S .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 139 (1-2) :255-258
[2]  
*BRIT PHARM, 2000, BRIT PHARM GEN MON, P1668
[3]  
Feddah MR, 2000, J PHARM PHARM SCI, V3, P317
[4]   Influence of respiratory spacer devices on aerodynamic particle size distribution and fine particle mass of beclomethasone from metered-dose inhalers [J].
Feddah, MR ;
Davies, NM ;
Gipps, EM ;
Brown, KF .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (04) :477-485
[5]   THE INFLUENCE OF SAMPLING CHAMBER DIMENSIONS ON AEROSOL-PARTICLE SIZE MEASUREMENT BY CASCADE IMPACTOR AND TWIN IMPINGER [J].
FULTS, K ;
CYR, TD ;
HICKEY, AJ .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1991, 43 (10) :726-728
[6]  
Hickey A.J., 1992, PHARM INHALATION AER, V2nd ed, P219
[7]  
HINDS WC, 1982, AEROSOL TECHNOLOGY P, P144
[8]   AN IN-VITRO EVALUATION OF VARIOUS SPACER DEVICES FOR METERED-DOSE INHALERS USING THE TWIN-IMPINGER [J].
HOLZNER, PM ;
MULLER, BW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1994, 106 (01) :69-75
[9]   DIFFERENCES IN AERODYNAMIC PARTICLE-SIZE DISTRIBUTIONS OF INNOVATOR AND GENERIC BECLOMETHASONE DIPROPIONATE AEROSOLS USED WITH AND WITHOUT A LARGE-VOLUME SPACER [J].
KENYON, CJ ;
DEWSBURY, NJ ;
NEWMAN, SP .
THORAX, 1995, 50 (08) :846-850
[10]  
KIM CS, 1985, AM REV RESPIR DIS, V132, P137