Windmill artifact in multi-slice helical CT

被引:20
|
作者
Silver, M [1 ]
Taguchi, K [1 ]
Hein, I [1 ]
Chiang, BS [1 ]
Kazama, M [1 ]
Mori, I [1 ]
机构
[1] BioImaging Res, Lincolnshire, IL 60069 USA
来源
MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3 | 2003年 / 5032卷
关键词
multi-slice CT; helical CT; artifacts;
D O I
10.1117/12.483585
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multi-slice helical CT-systems suffer from windmill artifacts: black/white patterns that spin off of features with high, longitudinal gradients. The number of black/white pairs matches the number of slices (detector rows) in the multi-slice detector. The period of the spin is the same as the helical pitch. We investigate the cause of the pattern by following the traces of selected voxels, through the multi-slice detector array as a function of view position. This forms an "extracted sinogram" which represents the data used to reconstruct that specific voxel. Now we can determine the cause of the artifact by correlating the windmill streak in the image with the extracted data. The investigation shows that inadequate sampling along the longitudinal direction causes the artifact.
引用
收藏
页码:1918 / 1927
页数:10
相关论文
共 50 条
  • [1] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [2] Algorithm for image reconstruction in multi-slice helical CT
    Taguchi, K
    Aradate, H
    MEDICAL PHYSICS, 1998, 25 (04) : 550 - 561
  • [3] Multi-slice helical CT: Principles, imaging characteristics, and performance
    Hu, H
    He, HD
    Fox, S
    Ackelsberg, S
    Strong, G
    Seidenschnur, G
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 637 - 639
  • [4] Analytical models for multi-slice helical CT performance parameters
    Hsieh, J
    MEDICAL PHYSICS, 2003, 30 (02) : 169 - 178
  • [5] Analytical noise and slice-sensitivity-profile models for multi-slice helical CT
    Hsieh, J
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 112 - 119
  • [6] Field-of-view dependent helical pitch in multi-slice CT
    Silver, MD
    Taguchi, K
    Han, KS
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 839 - 850
  • [7] Principles and applications of multi-slice CT
    Ohnesorge, B
    Flohr, T
    Schaller, S
    Klingenbeck-Regn, K
    Becker, C
    Schöpf, UJ
    Brüning, R
    Reiser, MF
    RADIOLOGE, 1999, 39 (11): : 923 - 931
  • [8] Evaluation of dual-front active contour segmentation and metal shadow filling methods on metal artifact reduction in multi-slice helical CT
    Li, Hua
    Yu, Lifeng
    Guimaraes, Luis S.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [9] Radiation exposure in multi-slice CT of the heart
    Cohnen, M
    Poll, L
    Püttmann, C
    Ewen, K
    Mödder, U
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 295 - 299
  • [10] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    MEDICAL PHYSICS, 1999, 26 (11) : 2223 - 2230