Sources of error in bioimpedance spectroscopy

被引:57
作者
Bolton, MP [1 ]
Ward, LC
Khan, A
Campbell, I
Nightingale, P
Dewit, O
Elia, M
机构
[1] Withington Hosp, Intens Care Unit, Manchester M20 2LR, Lancs, England
[2] Christie Hosp, Manchester, Lancs, England
[3] MRC, Dunn Clin Nutr Ctr, Cambridge CB2 1QL, England
[4] Univ Manchester, Dept Anaesthesia, Manchester, Lancs, England
关键词
bioimpedance; Cole-Cole model; intensive care;
D O I
10.1088/0967-3334/19/2/011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Two different makes of bioimpedance spectrometer (UniQuest-SEAC SFB3 and Xitron 4000B) were used for a series of measurements on volunteers and patients in intensive care. Although each machine was accurate over the frequency range 5 to 500 kHz when bench tested on model resistor-capacitor circuits, significant differences in their recorded impedance parameters appeared when used in vivo, especially on intensive care patients. A series of laboratory tests was performed on each machine simulating the situation in vivo to identify possible reasons for these differences. Whilst stray capacitance in the environment was identified as the major contributor to variability in high-frequency performance, interaction between electrode impedance and lead positioning was also a factor. The observed phase shift with frequency or time delay (T-d) used in the Xitron modelling software appears to be the result of a time constant caused by stray capacitance and so is unlikely to have any biological meaning. Significant differences in the in vivo numerical values produced by bioimpedance spectrometers may be attributed to instrument design, data processing and, in particular, the clinical environment.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 17 条
[1]  
CHUMLEA WC, 1994, NUTR REV, V52, P123, DOI 10.1111/j.1753-4887.1994.tb01404.x
[2]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[3]   Electric impedance of suspensions of spheres. [J].
Cole, KS .
JOURNAL OF GENERAL PHYSIOLOGY, 1928, 12 (01) :29-36
[4]  
Cornish BH, 1996, EUR J CLIN NUTR, V50, P159
[5]   IMPROVED PREDICTION OF EXTRACELLULAR AND TOTAL-BODY WATER USING IMPEDANCE LOCI GENERATED BY MULTIPLE FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
CORNISH, BH ;
THOMAS, BJ ;
WARD, LC .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03) :337-346
[6]  
DELORENZO A, 1994, RENAL PHYSIOL BIOCH, V17, P326
[7]   Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558
[8]  
DELORENZO A, 1997, J APPL PHYSIOL, V83, P1782
[9]  
KUSHNER RF, 1992, J AM COLL NUTR, V11, P199
[10]   VALIDATION OF BIOELECTRICAL-IMPEDANCE MEASUREMENTS AS A METHOD TO ESTIMATE BODY-WATER COMPARTMENTS [J].
LICHTENBELT, WDV ;
WESTERTERP, KR ;
WOUTERS, L ;
LUIJENDIJK, SCM .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (02) :159-166