Simultaneous Head and Spine MR Imaging in Children Using a Dedicated Multichannel Receiver System at 3T

被引:4
|
作者
Li, Nan [1 ,2 ,3 ]
Zheng, Hui [5 ]
Xu, Guangzu [6 ]
Gui, Ting [5 ]
Yin, Qiufeng [5 ]
Chen, Qiaoyan [1 ,2 ]
Lee, Jo [1 ,2 ]
Xin, Yang [6 ]
Zhang, Shuheng [6 ]
He, Qiang [6 ]
Zhang, Xiaoliang [7 ]
Liu, Xin [1 ,2 ]
Zheng, Hairong [1 ,2 ]
Wang, Dengbin [5 ]
Li, Ye [1 ,4 ]
机构
[1] Chinese Acad Sci, Lauterbur Imaging Res Ctr, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Key Lab Magnet Resonance & Multimodal Imaging Gua, Shenzhen, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Univ Chinese Acad Sci, Key Lab Magnet Resonance & Multimodal Imaging Gua, Beijing 100049, Peoples R China
[5] Shanghai Jiao Tong Univ, Xinhua Hosp, Dept Radiol, Sch Med, Shanghai 200092, Peoples R China
[6] Shanghai United Imaging Healthcare, Shanghai, Peoples R China
[7] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
基金
国家重点研发计划;
关键词
Head; Magnetic resonance imaging; Radio frequency; Signal to noise ratio; Pediatrics; Magnetic heads; Image segmentation; Pediatrics imaging; head and spine MR imaging; SNR; resolution; radiofrequency (RF) coil; WHOLE-BODY MRI; PHASED-ARRAY; PERFORMANCE; CHALLENGES; SENSITIVITY; BRAIN;
D O I
10.1109/TBME.2021.3082149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The purpose of this work was to enable simultaneous head and spine Magnetic Resonance imaging (MRI) in children at 3T by using a dedicated multichannel radiofrequency coil array system. Methods: A 24-channel head and spine pediatric coil system was developed and constructed. The coil's performance was compared with a commercially available 24-channel adult head-neck coil and a spine coil (1-4 spine of 16-channel were selected). Signal-to-noise ratio (SNR) and parallel imaging capability were quantitatively evaluated by phantom studies and in vivo imaging experiments. With Institutional Review Board and Ethics Committee approval, the designed coil was used to acquire head and spine images on 27 children in clinical settings. Results: The pediatric coil provided substantial SNR improvements with an increase of 32% to 40% in the brain region and up to a two-fold increase in the surface. SNR increased by at least 18% in the spine region. The coil enabled higher resolution and a faster imaging speed, owing to significantly improved SNR. Extensive coverage of the coil enabled high-quality fast imaging from head-neck to the whole spine. Good image quality with an average score 4.63 out of 5 was achieved using the developed pediatric coil in clinical studies. Conclusion: Simultaneous head and spine MRI with superior performance have been successfully acquired in children subjects at 3T using the dedicated 24-channel head and spine pediatric coil system. Significance: The 24-channel pediatric coil system potentially can enhance pediatric head and spine MRI in clinical research and diagnosis.
引用
收藏
页码:3659 / 3670
页数:12
相关论文
共 50 条
  • [41] Ferumoxytol as an off-label contrast agent in body 3T MR angiography: a pilot study in children
    Ruangwattanapaisarn, Nichanan
    Hsiao, Albert
    Vasanawala, Shreyas S.
    PEDIATRIC RADIOLOGY, 2015, 45 (06) : 831 - 839
  • [42] MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils
    Nagarajan, Rajakumar
    Margolis, Daniel J. A.
    Raman, Steven S.
    Ouellette, David
    Sarma, Manoj K.
    Reiter, Robert E.
    Thomas, M. Albert
    MAGNETIC RESONANCE INSIGHTS, 2013, 6 : 51 - 58
  • [43] Magnetic Resonance Thermometry of Focused Ultrasound Using a Preclinical Focused Ultrasound Robotic System at 3T
    Filippou, Antria
    Evripidou, Nikolas
    Georgiou, Andreas
    Georgiou, Leonidas
    Chrysanthou, Antreas
    Ioannides, Cleanthis
    Damianou, Christakis
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (04) : 583 - 596
  • [44] Ferumoxytol as an off-label contrast agent in body 3T MR angiography: a pilot study in children
    Nichanan Ruangwattanapaisarn
    Albert Hsiao
    Shreyas S. Vasanawala
    Pediatric Radiology, 2015, 45 : 831 - 839
  • [45] Evaluation of a Portable Doppler Ultrasound Gating Device for Fetal Cardiac MR Imaging: Initial Results at 1.5T and 3T
    Kording, Fabian
    Schoennagel, Bjoern P.
    de Sousa, Manuela Tavares
    Fehrs, Kai
    Adam, Gerhard
    Yamamura, Jin
    Ruprecht, Christian
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (04) : 308 - 317
  • [46] Clinical safety of the ProMRI implantable cardioverter-defibrillator systems during head and lower lumbar magnetic resonance imaging at 3T: results of the ProMRI 3T ENHANCED Master study
    Zbinden, Rainer
    Wollmann, Christian
    Brachmann, Johannes
    Michaelsen, Jochen
    Steinwender, Clemens
    Kovoor, Pramesh
    Kelle, Sebastian
    McGavigan, Andrew D.
    Ching, Chi Keong
    Figtree, Gemma A.
    Schmidt, Jan
    Timmel, Tobias
    Lotz, Joachim
    EUROPACE, 2019, 21 (11): : 1678 - 1685
  • [47] Fully automated detection of paramagnetic rims in multiple sclerosis lesions on 3T susceptibility-based MR imaging
    Lou, Carolyn
    Sati, Pascal
    Absinta, Martina
    Clark, Kelly
    Dworkin, Jordan D.
    Valcarcel, Alessandra M.
    Schindler, Matthew K.
    Reich, Daniel S.
    Sweeney, Elizabeth M.
    Shinohara, Russell T.
    NEUROIMAGE-CLINICAL, 2021, 32
  • [48] Assessment of MR Compatibility of a PET Insert Developed for Simultaneous Multiparametric PET/MR Imaging on an Animal System Operating at 7 T
    Wehrl, Hans F.
    Judenhofer, Martin S.
    Thielscher, Axel
    Martirosian, Petros
    Schick, Fritz
    Pichler, Bernd J.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 269 - 279
  • [49] Parenchymal Hypointense Foci Associated with Developmental Venous Anomalies: Evaluation by Phase-Sensitive MR Imaging at 3T
    Takasugi, M.
    Fujii, S.
    Shinohara, Y.
    Kaminou, T.
    Watanabe, T.
    Ogawa, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) : 1940 - 1944
  • [50] Characterizing amide proton transfer imaging in haemorrhage brain lesions using 3T MRI
    Jeong, Ha-Kyu
    Han, Kyunghwa
    Zhou, Jinyuan
    Zhao, Yansong
    Choi, Yoon Seong
    Lee, Seung-Koo
    Ahn, Sung Soo
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1577 - 1584