Simultaneous Head and Spine MR Imaging in Children Using a Dedicated Multichannel Receiver System at 3T

被引:4
|
作者
Li, Nan [1 ,2 ,3 ]
Zheng, Hui [5 ]
Xu, Guangzu [6 ]
Gui, Ting [5 ]
Yin, Qiufeng [5 ]
Chen, Qiaoyan [1 ,2 ]
Lee, Jo [1 ,2 ]
Xin, Yang [6 ]
Zhang, Shuheng [6 ]
He, Qiang [6 ]
Zhang, Xiaoliang [7 ]
Liu, Xin [1 ,2 ]
Zheng, Hairong [1 ,2 ]
Wang, Dengbin [5 ]
Li, Ye [1 ,4 ]
机构
[1] Chinese Acad Sci, Lauterbur Imaging Res Ctr, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Key Lab Magnet Resonance & Multimodal Imaging Gua, Shenzhen, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Univ Chinese Acad Sci, Key Lab Magnet Resonance & Multimodal Imaging Gua, Beijing 100049, Peoples R China
[5] Shanghai Jiao Tong Univ, Xinhua Hosp, Dept Radiol, Sch Med, Shanghai 200092, Peoples R China
[6] Shanghai United Imaging Healthcare, Shanghai, Peoples R China
[7] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
基金
国家重点研发计划;
关键词
Head; Magnetic resonance imaging; Radio frequency; Signal to noise ratio; Pediatrics; Magnetic heads; Image segmentation; Pediatrics imaging; head and spine MR imaging; SNR; resolution; radiofrequency (RF) coil; WHOLE-BODY MRI; PHASED-ARRAY; PERFORMANCE; CHALLENGES; SENSITIVITY; BRAIN;
D O I
10.1109/TBME.2021.3082149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The purpose of this work was to enable simultaneous head and spine Magnetic Resonance imaging (MRI) in children at 3T by using a dedicated multichannel radiofrequency coil array system. Methods: A 24-channel head and spine pediatric coil system was developed and constructed. The coil's performance was compared with a commercially available 24-channel adult head-neck coil and a spine coil (1-4 spine of 16-channel were selected). Signal-to-noise ratio (SNR) and parallel imaging capability were quantitatively evaluated by phantom studies and in vivo imaging experiments. With Institutional Review Board and Ethics Committee approval, the designed coil was used to acquire head and spine images on 27 children in clinical settings. Results: The pediatric coil provided substantial SNR improvements with an increase of 32% to 40% in the brain region and up to a two-fold increase in the surface. SNR increased by at least 18% in the spine region. The coil enabled higher resolution and a faster imaging speed, owing to significantly improved SNR. Extensive coverage of the coil enabled high-quality fast imaging from head-neck to the whole spine. Good image quality with an average score 4.63 out of 5 was achieved using the developed pediatric coil in clinical studies. Conclusion: Simultaneous head and spine MRI with superior performance have been successfully acquired in children subjects at 3T using the dedicated 24-channel head and spine pediatric coil system. Significance: The 24-channel pediatric coil system potentially can enhance pediatric head and spine MRI in clinical research and diagnosis.
引用
收藏
页码:3659 / 3670
页数:12
相关论文
共 50 条
  • [31] MR images of mouse brain using clinical 3T MR scanner and 4CH-Mouse coil
    Soo Mee Lim
    Eun Mi Park
    In Kyoon Lyoo
    Junghyun Lee
    Bo Mi Han
    Jeong Kyong Lee
    Su Bin Lee
    Journal of the Korean Physical Society, 2015, 67 : 237 - 242
  • [32] MR images of mouse brain using clinical 3T MR scanner and 4CH-Mouse coil
    Lim, Soo Mee
    Park, Eun Mi
    Lyoo, In Kyoon
    Lee, Junghyun
    Han, Bo Mi
    Lee, Jeong Kyong
    Lee, Su Bin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 237 - 242
  • [33] Dynamic contrast-enhanced susceptibility-weighted perfusion imaging of intracranial tumors: a study using a 3T MR scanner
    Senturk, Senem
    Oguz, Kader Karli
    Cila, Aysenur
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2009, 15 (01) : 3 - 12
  • [34] Human hand imaging using a 20 cm high-temperature superconducting coil in a 3T magnetic resonance imaging system
    Lin, In-Tsang
    Yang, Hong-Chang
    Hsieh, Chang-Wei
    Jao, Tun
    Chen, Jyh-Horng
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (12)
  • [35] Improvement of SNR and acquisition acceleration using a 32-channel head coil compared to a 12-channel head coil at 3T
    Reiss-Zimmermann, Martin
    Gutberlet, Marcel
    Koestler, Herbert
    Fritzsch, Dominik
    Hoffmann, Karl-Titus
    ACTA RADIOLOGICA, 2013, 54 (06) : 702 - 708
  • [36] What is the optimal b value in diffusion-weighted MR imaging to depict prostate cancer at 3T?
    T. Metens
    D. Miranda
    J. Absil
    C. Matos
    European Radiology, 2012, 22 : 703 - 709
  • [37] Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction
    Lupo, Janine M.
    Lee, Michael C.
    Han, Eric T.
    Cha, Soonmee
    Chang, Susan M.
    Berger, Mitchel S.
    Nelson, Sarah J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 520 - 529
  • [38] Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High-Performance Gradients
    Camerucci, Emanuele
    Campeau, Norbert G.
    Trzasko, Joshua D.
    Gray, Erin M.
    Bernstein, Matt A.
    Cogswell, Petrice M.
    Shu, Yunhong
    Foo, Thomas K.
    Huston, John, III
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 166 - 175
  • [39] Diffusion tensor imaging in early amyotrophic lateral sclerosis using 3T magnetic resonance imaging
    Sarsilmaz, Aysegul
    Firat, Zeynep
    Ulug, Aziz M.
    Karlikaya, Geysu
    Bingol, Canan Aykut
    Hamamci, Andac
    Kovanlikaya, Ilhami
    NEUROLOGICAL SCIENCES AND NEUROPHYSIOLOGY, 2018, 35 (02): : 102 - 107
  • [40] Prostate MR imaging at 3T with a longitudinal array endorectal surface coil and phased array body coil
    Kim, David Y.
    Schnall, Mitchell D.
    Rosen, Mark A.
    Connick, Thomas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1327 - 1330