Three-dimensional on-chip continuous-flow polymerase chain reaction employing a single heater

被引:38
|
作者
Wu, Wenming [1 ,2 ]
Lee, Nae Yoon [1 ,2 ]
机构
[1] Kyungwon Univ, Div BioNano Technol, Songnam 461701, Gyeonggi do, South Korea
[2] Kyungwon Univ, Coll BioNano Technol, Songnam 461701, Gyeonggi do, South Korea
关键词
On-chip polymerase chain reaction (PCR); Multi-layer microdevice; 3D fluidic conduit; A single heater; DNA amplification; TEMPERATURE CONTROL; DNA ANALYSIS; AMPLIFICATION; PCR; DEVICE; MICROCHIP;
D O I
10.1007/s00216-011-4947-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multi-step temperature control in a polymerase chain reaction (PCR) is a limiting factor in device miniaturization and portability. In this study, we propose the fabrication of a three-dimensional (3D) microdevice employing a single heater to minimize temperature control required for an on-chip continuous-flow PCR as well as the overall footprint by stacking the device in multi-layers. Two poly(dimethylsiloxane) (PDMS) layers with differing thicknesses are vertically stacked with their microchannel-engraved sides facing down. Through-holes are made in the thicker PDMS layer, which is sandwiched between a glass substrate at the bottom and the thinner PDMS layer at the top. In this way, a fluidic conduit is realized in a 3D configuration. The assembled 3D microdevice is then placed onto a heater glass-side down. The interface of the two PDMS layers displays a relatively lower temperature than that of the PDMS and glass layers due to the low thermal conductivity of the PDMS and its physical distance from the heater. The denaturation temperature can be controlled by adjusting the temperature of the heater, while the annealing/extension temperature can be controlled automatically by molding the thicker bottom PDMS layer into the appropriate thickness calculated using a numerical derivation proposed in this study. In this way, a cumbersome temperature measurement step is eliminated. DNA amplification was successfully carried out using the proposed 3D fluidic microdevice, and the intensity of the resulting amplicon was comparable to that obtained using a thermal cycler. This novel concept of adopting a single heating source greatly simplifies the temperature control issue present in an on-chip continuous-flow PCR. It also allows the use of a commercialized hot plate as a potential heat source, paving the way for device miniaturization and portability in a highly cost-effective manner. In this study, a simple and facile technique to make arrays of through-holes for the fluidic interconnection inside a 3D channel configuration is also addressed.
引用
收藏
页码:2053 / 2060
页数:8
相关论文
共 50 条
  • [41] A THERMAL SYSTEM FOR A HIGH THROUGHPUT CONTINUOUS FLOW POLYMERASE CHAIN REACTION DEVICE (CFPCR)
    Chen, P. -C.
    Park, D. S.
    You, B. H.
    Kim, N.
    Park, T.
    Desta, Y.
    Park, S.
    Nikitopoulos, D. E.
    Soper, S. A.
    Murphy, M. C.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 13, PTS A AND B, 2009, : 313 - 317
  • [42] Pressure-driven one-step solid phase-based on-chip sample preparation on a microfabricated plastic device and integration with flow-through polymerase chain reaction (PCR)
    Tran, Hong Hanh
    Trinh, Kieu The Loan
    Lee, Nae Yoon
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 936 : 88 - 94
  • [43] THERMAL MODELING FOR DESIGN OPTIMIZATION OF A MICROFLUIDIC DEVICE FOR CONTINUOUS FLOW POLYMERASE CHAIN REACTION (PCR)
    Kumar, Sumeet
    Thorsen, Todd
    Das, Sarit Kumar
    HT2008: PROCEEDING OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, VOL 3, 2009, : 323 - 330
  • [44] Silicon Based System for Single-Nucleotide-Polymorphism Detection: Chip Fabrication and Thermal Characterization of Polymerase Chain Reaction Microchamber
    Majeed, Bivragh
    Jones, Ben
    Tezcan, Deniz S.
    Tutunjyan, Nina
    Haspeslagh, Luc
    Peeters, Sara
    Fiorini, Paolo
    Op de Beeck, Maaike
    Van Hoof, Chris
    Hiraoka, Maki
    Tanaka, Hiroyuki
    Yamashita, Ichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (04)
  • [45] THREE DIMENSIONAL SIMULATION OF RAYLEIGH-BENARD CONVECTION FOR RAPID MICROSCALE POLYMERASE CHAIN REACTION
    Muddu, Radha
    Ugaz, Victor M.
    Hassan, Yassin A.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 1, PTS A-C, 2009, : 2109 - 2118
  • [46] Diameter-definable tubing-microchips for applications in both continuous-flow and TEC-modulated on-chip qPCRs with reaction signal analyzed between different types of Teflon-polymers: PTFE and FEP
    Jiang, Yangyang
    Wu, Guizhu
    Li, Yuanming
    Wu, Wenming
    RSC ADVANCES, 2019, 9 (05) : 2650 - 2656
  • [47] A Practical Liquid Plug Flow-through Polymerase Chain-Reaction System Based on a Heat-Resistant Resin Chip
    Fuchiwaki, Yusuke
    Saito, Masato
    Wakida, Shin-ichi
    Tamiya, Eiichi
    Nagai, Hidenori
    ANALYTICAL SCIENCES, 2011, 27 (03) : 225 - 230
  • [48] Integrated continuous flow polymerase chain reaction and micro-capillary electrophoresis system with bioaffinity preconcentration
    Njoroge, Samuel K.
    Witek, Magorzata A.
    Battle, Katrina N.
    Immethun, Vicki E.
    Hupert, Mateusz L.
    Soper, Steven A.
    ELECTROPHORESIS, 2011, 32 (22) : 3221 - 3232
  • [49] An integrated allele-specific polymerase chain reaction-microarray chip for multiplex single nucleotide polymorphism typing
    Choi, Jong Young
    Kim, Yong Tae
    Byun, Ju-Young
    Ahn, Jinwoo
    Chung, Soyi
    Gweon, Dae-Gab
    Kim, Min-Gon
    Seo, Tae Seok
    LAB ON A CHIP, 2012, 12 (24) : 5146 - 5154
  • [50] Portable plastic syringe as a self-actuated pump for long-distance uniform delivery of liquid inside a microchannel and its application for flow-through polymerase chain reaction on chip
    Wu, Wenming
    Kieu The Loan Trinh
    Zhang, Yu
    Lee, Nae Yoon
    RSC ADVANCES, 2015, 5 (16): : 12071 - 12077