Fatigue analysis of computer-aided design/computer-aided manufacturing resin-based composite vs. lithium disilicate glass-ceramic

被引:33
作者
Ankyu, Shuhei [1 ]
Nakamura, Keisuke [2 ]
Harada, Akio [1 ]
Hong, Guang [3 ]
Kanno, Taro [1 ]
Niwano, Yoshimi [2 ]
Ortengren, Ulf [4 ,5 ]
Egusa, Hiroshi [1 ]
机构
[1] Tohoku Univ, Div Mol & Regenerat Prosthodont, Grad Sch Dent, Sendai, Miyagi, Japan
[2] Tohoku Univ, Lab Redox Regulat, Grad Sch Dent, Sendai, Miyagi, Japan
[3] Tohoku Univ, Liaison Ctr Innovat Dent, Grad Sch Dent, Sendai, Miyagi, Japan
[4] Arctic Univ Norway, Dept Clin Dent, Fac Hlth Sci, Tromso, Norway
[5] Univ Gothenburg, Dept Cariol, Inst Odontol, Sahlgrenska Acad, Gothenburg, Sweden
关键词
fatigue; lithium disilicate glass-ceramic; mechanical cycling; resin-based composite; thermal cycling; FRACTURE-RESISTANCE; MOLAR CROWNS; FLEXURAL STRENGTH; MARGINAL ADAPTATION; DENTAL RESTORATIONS; SURFACE; SIMULATION; CEMENTS; STRESS; FORCE;
D O I
10.1111/eos.12278
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Resin-based composite molar crowns made by computer-aided design/computer-aided manufacturing (CAD/CAM) systems have been proposed as an inexpensive alternative to metal-ceramic or all-ceramic crowns. However, there is a lack of scientific information regarding fatigue resistance. This study aimed to analyze the fatigue behavior of CAD/CAM resin-based composite compared with lithium disilicate glass-ceramic. One-hundred and sixty bar-shaped specimens were fabricated using resin-based composite blocks [Lava Ultimate (LU); 3M/ESPE] and lithium disilicate glass-ceramic [IPS e.max press (EMP); Ivoclar/Vivadent]. The specimens were divided into four groups: no treatment (NT); thermal cycling (TC); mechanical cycling (MC); and thermal cycling followed by mechanical cycling (TCMC). Thermal cycling was performed by alternate immersion in water baths of 5 degrees C and 55 degrees C for 5 x 10(4) cycles. Mechanical cycling was performed in a three-point bending test, with a maximum load of 40 N, for 1.2 x 10(6) cycles. In addition, LU and EMP molar crowns were fabricated and subjected to fatigue treatments followed by load-to-failure testing. The flexural strength of LU was not severely reduced by the fatigue treatments. The fatigue treatments did not significantly affect the fracture resistance of LU molar crowns. The results demonstrate the potential of clinical application of CAD/CAM-generated resin-based composite molar crowns in terms of fatigue resistance.
引用
收藏
页码:387 / 395
页数:9
相关论文
共 44 条
  • [1] 3M ESPE, 2016, LAV ULT CAD CAM REST
  • [2] Is Weibull's modulus really a material constant? Example case with interacting collinear cracks
    Afferrante, L.
    Ciavarella, M.
    Valenza, E.
    [J]. INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2006, 43 (17) : 5147 - 5157
  • [3] Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations
    Alt, Vanessa
    Hannig, Matthias
    Woestmann, Bernd
    Balkenhol, Markus
    [J]. DENTAL MATERIALS, 2011, 27 (04) : 339 - 347
  • [4] [Anonymous], ISO6872
  • [5] [Anonymous], MODERN CERAMIC ENG P
  • [6] Anusavice KJ., 2013, Philips' Materiais Dentarios, V12A, P48
  • [7] Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
    Attia, A
    Abdelaziz, KM
    Freitag, S
    Kern, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) : 117 - 123
  • [8] INFLUENCE OF TEST METHOD ON FAILURE STRESS OF BRITTLE DENTAL MATERIALS
    BAN, S
    ANUSAVICE, KJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 (12) : 1791 - 1799
  • [9] Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies.
    Behr M.
    Hindelang U.
    Rosentritt M.
    Lang R.
    Handel G.
    [J]. Clinical Oral Investigations, 2000, 4 (1) : 25 - 30
  • [10] Behr M, 2003, INT J PROSTHODONT, V16, P538