A Simple, Fast, and Inexpensive Simultaneous Determination of Trace Bismuth(III) and Lead(II) in Water Samples by Adsorptive Stripping Voltammetry

被引:6
作者
Grabarczyk, Malgorzata [1 ]
Adamczyk, Marzena [1 ]
机构
[1] Marie Curie Sklodowska Univ, Dept Analyt Chem & Instrumental Anal, Fac Chem, PL-20031 Lublin, Poland
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; NATURAL-WATER; ELECTROCHEMICAL DETERMINATION; PRECONCENTRATION SYSTEM; COPPER; CADMIUM; CUPFERRON; ELECTRODE; URINE; INTERFERENCES;
D O I
10.1155/2017/1486497
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast, and inexpensive voltammetric method for the simultaneous determination of trace bismuth(III) and lead(II) using (Hg(Ag) FE) as a working electrode was optimized. For adsorptive stripping voltammetric determination of Bi(III) and Pb(II) in a single scan, the cupferron was applied as a complexing agent. Experimental conditions under which these elements can be simultaneously detected include 0.1 mol L-1 acetate buffer (pH = 4.6), 1 x 10(-4) mol L-1 cupferron, accumulation potential -0.05V, and accumulation time 30 s. The experiments were performed without deaeration of the solutions. The calibration graph was linear from 2 x 10(-9) mol L-1 to 1 x 10(-7) mol L-1 for the simultaneous presence of bismuth and lead. The detection limits for preconcentration time of 30 s were 6.7 x 10(-10) mol L-1 and 8.8 x 10(-10) mol L-1 for bismuth and lead, respectively. The application of this procedure was tested by analyzing certified reference material (SPS-WW1 Wastewater) and Lake Zemborzyce water (eastern areas of Poland).
引用
收藏
页数:6
相关论文
共 42 条
[1]   Removal of lead ions from industrial waste water by different types of natural materials [J].
Abdel-Halim, SH ;
Shehata, AMA ;
El-Shahat, MF .
WATER RESEARCH, 2003, 37 (07) :1678-1683
[2]   Construction of Modified Carbon Paste Electrode for Highly Sensitive Simultaneous Electrochemical Determination of Trace Amounts of Copper (II) and Cadmium (II) [J].
Afkhami, Abbas ;
Soltani-Shahrivar, Morteza ;
Ghaedi, Hamed ;
Madrakian, Tayyebeh .
ELECTROANALYSIS, 2016, 28 (02) :296-303
[3]   Environmental lead toxicity and nutritional factors [J].
Ahamed, Maqusood ;
Kaleem, Mohd. ;
Siddiqui, Javed .
CLINICAL NUTRITION, 2007, 26 (04) :400-408
[4]   Spectrophotometric determination of lead in industrial, environmental, biological and soil samples using 2,5-dimercapto-1,3,4-thiadiazole [J].
Ahmed, MJ ;
Mamun, MA .
TALANTA, 2001, 55 (01) :43-54
[5]   Simultaneous determination of copper, bismuth and lead by adsorptive stripping voltammetry in the presence of thymolphthalexone [J].
Babaei, Ali ;
Shams, Esmaeil ;
Samadzadeh, Ali .
ANALYTICAL SCIENCES, 2006, 22 (07) :955-959
[6]   Microwave-induced Combustion Coupled to Flame Furnace Atomic Absorption Spectrometry for Determination of Cadmium and Lead in Botanical Samples [J].
Barin, Juliano S. ;
Bartz, Fabiane R. ;
Dressler, Valderi L. ;
Paniz, Jose N. G. ;
Flores, Erico M. M. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9369-9374
[7]   Refreshable mercury film silver based electrode for determination of chromium(VI) using catalytic adsorptive stripping voltammetry [J].
Bas, B .
ANALYTICA CHIMICA ACTA, 2006, 570 (02) :195-201
[8]   Determination of bismuth in urine and prescription medicines using atomic absorption with an on-line hydride generation system [J].
Cadore, S ;
dos Anjos, AP ;
Baccan, N .
ANALYST, 1998, 123 (08) :1717-1719
[9]   3,8-Diaminobenzo[c]Cinnoline Derivatived Graphene Oxide Modified Graphene Oxide Sensor for the Voltammetric Determination of Cd2+ and Pb2+ [J].
Celik, Gamze Kuzu ;
Uzdurmez, Ahmet Ferat ;
Erkal, Asli ;
Kilic, Emine ;
Solak, Ali Osman ;
Ustundag, Zafer .
ELECTROCATALYSIS, 2016, 7 (03) :207-214
[10]   Lead isotopes in tap water: implications for Pb sources within a municipal water supply system [J].
Cheng, Z ;
Foland, KA .
APPLIED GEOCHEMISTRY, 2005, 20 (02) :353-365