Photon Propagation Correction in 3D Photoacoustic Image Reconstruction using Monte Carlo Simulation

被引:0
|
作者
Cheong, Yaw Jye [1 ,4 ]
Stantz, Keith M. [2 ,3 ]
机构
[1] IUPUI, Indianapolis, IN 46202 USA
[2] Purdue Univ, W Lafayette, IN 47907 USA
[3] Indiana Univ, Indianapolis, IN 46204 USA
[4] BrainLAB Inc, Westchester, IL USA
关键词
photoacoustic computed tomography; Monte Carlo; heterogeneity; NEAR-INFRARED SPECTROSCOPY; ADULT HEAD MODEL; LIGHT-PROPAGATION; OPTICAL TOMOGRAPHY; NON-SCATTERING; MEDIA; TRANSPORT; LAYER;
D O I
10.1117/12.842196
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: The purpose of this study is to develop a new 3-D iterative Monte Carlo algorithm to recover the heterogeneous distribution of molecular absorbers with a solid tumor. Introduction: Spectroscopic imaging (PCT-S) has the potential to identify a molecular species and quantify its concentration with high spatial fidelity. To accomplish this task, tissue attenuation losses during photon propagation in heterogeneous 3D objects is necessary. An iterative recovery algorithm has been developed to extract 3D heterogeneous parametric maps of absorption coefficients implementing a MC algorithm based on a single source photoacoustic scanner and to determine the influence of the reduced scattering coefficient on the uncertainty of recovered absorption coefficient. Material and Methods: This algorithm is tested for spheres and ellipsoids embedded in simulated mouse torso with optical absorption values ranging from 0.01-0.5/cm, for the same objects where the optical scattering is unknown (mu(s)'=7-13/cm), and for a heterogeneous distribution of absorbers. Results: Systemic and statistical errors in ma with a priori knowledge of mu(s)' and g are <2% (sphere) and <4% (ellipsoid) for all ma and without a priori knowledge of mu(s)' is <3% and <6%. For heterogenenous distributions of ma, errors are <4% and <5.5% for each object with a prior knowledge of mu s' and g, and to 7 and 14% when mu(s)' varied from 7-13/cm. Conclusions: A Monte Carlo code has been successfully developed and used to correct for photon propagation effects in simulated objects consistent with tumors.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Avalanche breakdown and quenching in Ge SPAD using 3D Monte Carlo simulation
    Dollfus, P.
    Saint-Martin, J.
    Cazimajou, T.
    Helleboid, R.
    Pilotto, A.
    Rideau, D.
    Bournel, A.
    Pala, M.
    SOLID-STATE ELECTRONICS, 2022, 194
  • [32] A parallel approach for Monte Carlo-based photon propagation simulation
    Rusu, Ionela
    Pentiuc, Stefan-Gheorghe
    Ungurean, Ioan
    Craciun, Elena-Gina
    2012 5TH ROMANIA TIER 2 FEDERATION GRID, CLOUD & HIGH PERFORMANCE COMPUTING SCIENCE (RO-LCG), 2012, : 78 - 81
  • [33] Estimation of crosstalk in LED fNIRS by photon propagation Monte Carlo simulation
    Iwano, Takayuki
    Umeyama, Shinji
    BIOPHOTONICS JAPAN 2015, 2015, 9792
  • [34] Implementation of 3D Monte Carlo PET Reconstruction Algorithm on GPU
    Wirth, A.
    Cserkaszky, A.
    Kari, B.
    Legrady, D.
    Feher, S.
    Czifrus, Sz
    Domonkos, B.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4106 - +
  • [35] Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study
    Lazaro, D
    El Bitar, Z
    Breton, V
    Hill, D
    Buvat, I
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3739 - 3754
  • [36] Scatter correction techniques in 3D PET: A Monte Carlo evaluation
    Castiglioni, I
    Cremonesi, O
    Gilardi, MC
    Bettinardi, V
    Rizzo, G
    Savi, A
    Bellotti, E
    Fazio, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2053 - 2058
  • [37] Accelerated Monte Carlo Scatter Correction for 3D PET.
    Holdsworth, CH
    Levin, CS
    Dahlbom, M
    Farquhar, TH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P
  • [38] Scatter correction techniques in 3D PET: a Monte Carlo evaluation
    Castiglioni, I.
    Cremonesi, O.
    Gilardi, M.C.
    Bettinardi, V.
    Rizzo, G.
    Savi, A.
    Bellotti, E.
    Fazio, F.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 : 738 - 742
  • [39] Evaluation of a Monte Carlo scatter correction in clinical 3D PET
    Holdsworth, CH
    Badawi, RD
    Santos, P
    Van den Abbeele, AD
    Hoffman, EJ
    El Fakhri, G
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2540 - 2544
  • [40] Statistical 3D image reconstruction for the RatCAP PET tomograph using a physically accurate, Monte Carlo based system matrix
    Shokouhi, S
    Vaska, P
    Southekal, S
    Schlyer, D
    Purschke, M
    Dzordzhadze, V
    Woody, C
    Stoll, S
    Alexoff, DL
    Rubins, D
    Villanueva, A
    Krishnamoorthy, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3901 - 3905