Photon Propagation Correction in 3D Photoacoustic Image Reconstruction using Monte Carlo Simulation

被引:0
|
作者
Cheong, Yaw Jye [1 ,4 ]
Stantz, Keith M. [2 ,3 ]
机构
[1] IUPUI, Indianapolis, IN 46202 USA
[2] Purdue Univ, W Lafayette, IN 47907 USA
[3] Indiana Univ, Indianapolis, IN 46204 USA
[4] BrainLAB Inc, Westchester, IL USA
关键词
photoacoustic computed tomography; Monte Carlo; heterogeneity; NEAR-INFRARED SPECTROSCOPY; ADULT HEAD MODEL; LIGHT-PROPAGATION; OPTICAL TOMOGRAPHY; NON-SCATTERING; MEDIA; TRANSPORT; LAYER;
D O I
10.1117/12.842196
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: The purpose of this study is to develop a new 3-D iterative Monte Carlo algorithm to recover the heterogeneous distribution of molecular absorbers with a solid tumor. Introduction: Spectroscopic imaging (PCT-S) has the potential to identify a molecular species and quantify its concentration with high spatial fidelity. To accomplish this task, tissue attenuation losses during photon propagation in heterogeneous 3D objects is necessary. An iterative recovery algorithm has been developed to extract 3D heterogeneous parametric maps of absorption coefficients implementing a MC algorithm based on a single source photoacoustic scanner and to determine the influence of the reduced scattering coefficient on the uncertainty of recovered absorption coefficient. Material and Methods: This algorithm is tested for spheres and ellipsoids embedded in simulated mouse torso with optical absorption values ranging from 0.01-0.5/cm, for the same objects where the optical scattering is unknown (mu(s)'=7-13/cm), and for a heterogeneous distribution of absorbers. Results: Systemic and statistical errors in ma with a priori knowledge of mu(s)' and g are <2% (sphere) and <4% (ellipsoid) for all ma and without a priori knowledge of mu(s)' is <3% and <6%. For heterogenenous distributions of ma, errors are <4% and <5.5% for each object with a prior knowledge of mu s' and g, and to 7 and 14% when mu(s)' varied from 7-13/cm. Conclusions: A Monte Carlo code has been successfully developed and used to correct for photon propagation effects in simulated objects consistent with tumors.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] 3D Model Feature Extraction Based on Light Propagation Simulation with Monte Carlo Method
    Liu, Hong-Hao
    Liu, Xian-Xi
    Zhang, Kai-Xing
    Lu, Shan
    Pueh, Lee Heow
    Song, Zheng-He
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2020, 40 (02): : 385 - 390
  • [22] Geometrical and Monte Carlo projectors in 3D PET reconstruction
    Aguiar, Pablo
    Rafecas, Magdalena
    Enrique Ortuno, Juan
    Kontaxakis, George
    Santos, Andres
    Pavia, Javier
    Ros, Domenec
    MEDICAL PHYSICS, 2010, 37 (11) : 5691 - 5702
  • [23] Targeted Fully 3D Monte Carlo Reconstruction in SPECT
    El Bitar, Ziad
    Petegnief, Yolande
    Hill, David
    Breton, Vincent
    Buvat, Irene
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3410 - 3413
  • [24] A Monte-Carlo simulation study on coarse septa for scatter correction in 3D PET
    Hasegawa, T
    Tanaka, E
    Yamashita, T
    Watanabe, M
    Yamaya, T
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2110 - 2114
  • [25] Investigation of accelerated Monte Carlo techniques for PET simulation and 3D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 74 - 81
  • [26] The 3D image reconstruction from photon number
    Damrongwatthanayothin, Burapa
    2006 International Symposium on Communications and Information Technologies,Vols 1-3, 2006, : 591 - 596
  • [27] 3D Monte Carlo neutron and photon transport code MCMG
    Deng, L. (deng_li@iapcm.ac.cn), 1600, Editorial Office of High Power Laser and Particle Beams, P.O. Box 919-805, Mianyang, 621900, China (25):
  • [28] Monte Carlo Simulation of Photon Migration in 3D Turbid Media Accelerated by Graphics Processing Units
    Fang, Qianqian
    Boas, David A.
    OPTICS EXPRESS, 2009, 17 (22): : 20178 - 20190
  • [29] 3D parallel Monte Carlo simulation of GaAs MESFETs
    Pennathur, S
    Sandalci, CK
    Koc, CK
    Goodnick, SM
    VLSI DESIGN, 1998, 6 (1-4) : 273 - 276
  • [30] Feasibility and value of fully 3D Monte Carlo reconstruction in single-photon emission computed tomography
    Lazaro, D
    Breton, V
    Buvat, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 195 - 200