Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction

被引:16
作者
Son, Jun Hyuk [1 ,2 ,3 ]
Lee, Hee Seung [4 ]
Lee, Sang Hyub [1 ,2 ]
Bang, Seungmin [4 ]
Kang, Jinwoo [1 ,2 ,5 ]
Paik, Woo Hyun [1 ,2 ]
Ryu, Ji Kon [1 ,2 ]
Kim, Yong-Tae [1 ,2 ]
机构
[1] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Internal Med, Seoul, South Korea
[2] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Liver Res Inst, Seoul, South Korea
[3] Inje Univ, Dept Internal Med, Ilsan Paik Hosp, Goyang, South Korea
[4] Yonsei Univ, Inst Gastroenterol, Dept Internal Med, Coll Med, Seoul, South Korea
[5] SMG SNU Boramae Med Ctr, Dept Gastroenterol & Hepatol, Seoul, South Korea
关键词
Malignant hilar biliary obstruction; Self-expandable metallic stent; Stent-in-stent; Revision; CHOLANGIOCARCINOMA; MANAGEMENT; DEPLOYMENT; EFFICACY;
D O I
10.1016/j.hbpd.2018.07.007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Endoscopic biliary decompression using bilateral self-expandable metallic stent (SEMS) placed using the stent-in-stent (SIS) technique is considered favorable for unresectable malignant hilar biliary obstruction (MHBO). However, occlusion of the bilateral SIS placement is frequent and revision can be challenging. This study was performed to investigate the efficacy, the long-term patency and the appropriate approach for revision of occluded bilateral SIS placement in unresectable MHBO. Methods: From January 2011 to July 2016, thirty-eight patients with unresectable MHBO underwent revision of occluded bilateral SIS placement. Clinical data including success rates and patency of revision, were retrospectively analyzed. Results: The technical success rate of revision was 76.3%. The clinical success rate of revision was 51.7% and mean patency of revision was 49.1 days. No significant predictive factor for clinical failure of revision was observed. The cell size of SEMS was not found to have significant effects on clinical success rates or revision patency. Conclusions: Revision of occluded bilateral SIS placement for MHBO showed fair patency and clinical success rate. Revision method and cell size of SEMS were not found to influence clinical outcomes. (C) 2018 First Affiliated Hospital, Zhejiang University School of Medicine in China. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:437 / 442
页数:6
相关论文
共 23 条
[1]   Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients [J].
Antunes Liberato, Manuel Jose ;
Tavares Canena, Jorge Manuel .
BMC GASTROENTEROLOGY, 2012, 12
[2]   Expandable metal stents for endoscopic bilateral stent-within-stent placement for malignant hilar biliary obstruction [J].
Chahal, Prabhleen ;
Baron, Todd H. .
GASTROINTESTINAL ENDOSCOPY, 2010, 71 (01) :195-199
[3]   Management of Occluded Metallic Stents in Malignant Hilar Biliary Stricture [J].
Fujii, Masakuni ;
Kawamoto, Hirofumi ;
Tsutsumi, Koichiro ;
Kato, Hironari ;
Hirao, Ken ;
Kurihara, Naoko ;
Mizuno, Osamu ;
Ishida, Etsuji ;
Ogawa, Tsuneyoshi ;
Fukatsu, Hirotoshi ;
Yamamoto, Kazuhide .
HEPATO-GASTROENTEROLOGY, 2013, 60 (123) :447-451
[4]   Y-shaped endoscopic bilateral metal stent placement for malignant hilar biliary obstruction: prospective long-term study [J].
Hwang, Jae Chul ;
Kim, Jin Hong ;
Lim, Sun Gyo ;
Kim, Soon Sun ;
Yoo, Byung Moo ;
Cho, Sung Won .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2011, 46 (03) :326-332
[5]   Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction [J].
Inoue, Tadahisa ;
Naitoh, Itaru ;
Okumura, Fumihiro ;
Ozeki, Takanori ;
Anbe, Kaiki ;
Iwasaki, Hiroyasu ;
Nishie, Hirotada ;
Mizushima, Takashi ;
Sano, Hitoshi ;
Nakazawa, Takahiro ;
Yoneda, Masashi ;
Joh, Takashi .
DIGESTIVE ENDOSCOPY, 2016, 28 (07) :731-737
[6]   SINGLE-SESSION ENDOSCOPIC BILATERAL Y-CONFIGURED PLACEMENT OF METAL STENTS FOR HILAR MALIGNANT BILIARY OBSTRUCTION [J].
Kanno, Yoshihide ;
Ito, Kei ;
Fujita, Naotaka ;
Noda, Yutaka ;
Kobayashi, Go ;
Obana, Takashi ;
Horaguchi, Jun ;
Takasawa, Osamu ;
Kato, Yuhei ;
Koshita, Shinsuke ;
Yamashita, Yasunobu ;
Ogawa, Takahisa .
DIGESTIVE ENDOSCOPY, 2011, 23 (01) :91-96
[7]   Endoscopic 3-branched partial stent-in-stent deployment of metallic stents in high-grade malignant hilar biliary stricture [J].
Kawamoto, Hirofumi ;
Tsutsumi, Koichiro ;
Fujii, Masakuni ;
Harada, Ryo ;
Kato, Hironari ;
Hirao, Ken ;
Kurihara, Naoko ;
Nakanishi, Takashi ;
Mizuno, Osamu ;
Ishida, Etsuji ;
Ogawa, Tsuneyoshi ;
Fukatsu, Hirotoshi ;
Sakaguchi, Kohsaku .
GASTROINTESTINAL ENDOSCOPY, 2007, 66 (05) :1030-1037
[8]   Usefulness of slimmer and open-cell-design stents for endoscopic bilateral stenting and endoscopic revision in patients with hilar cholangiocarcinoma [J].
Kim, Jeong Yeol ;
Kang, Dae Hwan ;
Kim, Hyung Wook ;
Choi, Cheol Woong ;
Du Kim, Il ;
Hwang, Jong Ho ;
Kim, Dong Uk ;
Eum, Jae Sup ;
Bae, Yong Mock .
GASTROINTESTINAL ENDOSCOPY, 2009, 70 (06) :1109-1115
[9]   High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction [J].
Kogure, Hirofumi ;
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Tsujino, Takeshi ;
Matsubara, Saburo ;
Yashima, Yoko ;
Ito, Yukiko ;
Hamada, Tsuyoshi ;
Takahara, Naminatsu ;
Miyabayashi, Koji ;
Mizuno, Suguru ;
Mohri, Dai ;
Kawakubo, Kazumichi ;
Sasaki, Takashi ;
Yamamoto, Natsuyo ;
Hirano, Kenji ;
Sasahira, Naoki ;
Tada, Minoru ;
Koike, Kazuhiko .
DIGESTIVE ENDOSCOPY, 2014, 26 (01) :93-99
[10]   Newly designed large cell Niti-S stent for malignant hilar biliary obstruction: a pilot study [J].
Kogure, Hirofumi ;
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Tsujino, Takeshi ;
Ito, Yukiko ;
Yamamoto, Keisuke ;
Mizuno, Suguru ;
Yagioka, Hiroshi ;
Kawakubo, Kazumichi ;
Sasaki, Takashi ;
Hirano, Kenji ;
Sasahira, Naoki ;
Tada, Minoru ;
Omata, Masao ;
Koike, Kazuhiko .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (02) :463-467