Effective utilization of excess energy in standalone hybrid renewable energy systems for improving comfort ability and reducing cost of energy: A review and analysis

被引:101
作者
Ismail, M. S. [1 ,2 ]
Moghavvemi, M. [2 ,3 ,4 ]
Mahlia, T. M. I. [5 ,6 ]
Muttaqi, K. M. [7 ]
Moghavvemi, S. [8 ]
机构
[1] Palestine Tech Univ Kadoorie, Dept Elect Engn, Tulkarm, Israel
[2] Univ Malaya, CRAE, Kuala Lumpur 50603, Malaysia
[3] Univ Malaya, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[4] Univ Sci & Culture, Tehran, Iran
[5] Univ Tenaga Nas, Dept Mech Engn, Kajang 43000, Selangor, Malaysia
[6] Syiah Kuala Univ, Dept Mech Engn, Banda Aceh 23111, Indonesia
[7] Univ Wollongong, Sch Elect Comp & Telecommun Engn, Wollongong, NSW, Australia
[8] Univ Malaya, Fac Business & Accountancy, Dept Operat & Management Informat Syst, Kuala Lumpur 50603, Malaysia
关键词
Dump load; Excess energy; Hybrid system; Renewable energy; POWER EXTRACTION CAPABILITY; CONTROL STRATEGIES; ALONE APPLICATIONS; HYDROGEN STORAGE; REMOTE CONSUMERS; WIND; OPTIMIZATION; GENERATION; DESIGN; SOLAR;
D O I
10.1016/j.rser.2014.10.051
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
One of the features that characterize renewable energy sources is their variability and intermittency. Intermittency covers both the predictable and unpredictable variations of their power outputs and uncertainty in the power availability. To overcome the drawback of intermittency, special design considerations should be taken into account. These additional design considerations increases the overall cost of the renewable energy systems. Adding storage system and/or backup source to the renewable sources is one of the measures used to guarantee the continuity of power supply to the loads, and therefore improve the reliability of the renewable energy systems. The operation of renewable energy systems results in the creation of surplus energy, which is the energy generated by renewable energy systems, but is not consumed by the loads in standalone power systems. Effective utilization of this excess energy has the potential to decrease the cost of energy (CUE) production by these hybrid renewable energy systems. In this paper, a review of the literature will be carried out in order to provide further insight into the approaches suggested in the literature on how to deal with the utilization of excess energy. Furthermore, various possible configurations of hybrid systems will be analyzed in detail for the effective utilization of the excess energy produced by hybrid systems. This is done in order to evaluate the effectiveness of utilization of excess energy by various means, especially for improving the living space comfort ability and decreasing the COE. Case studies will be carried out to demonstrate the proposed configurations for the effective utilization of the excess energy, and the results will be presented. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:726 / 734
页数:9
相关论文
共 52 条
[1]   Performance of a stand-alone renewable energy system based on energy storage as hydrogen [J].
Agbossou, K ;
Kolhe, M ;
Hamelin, J ;
Bose, TK .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (03) :633-640
[2]   Climate change impacts on electricity demand in the State of New South Wales, Australia [J].
Ahmed, T. ;
Muttaqi, K. M. ;
Agalgaonkar, A. P. .
APPLIED ENERGY, 2012, 98 :376-383
[3]   Hybrid renewable energy systems for power generation in stand-alone applications: A review [J].
Bajpai, Prabodh ;
Dash, Vaishalee .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :2926-2939
[4]   Simulation and optimization of stand-alone hybrid renewable energy systems [J].
Bernal-Agustin, Jose L. ;
Dufo-Lopez, Rodolfo .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08) :2111-2118
[5]   A review on Integrated Renewable Energy System based power generation for stand-alone applications: Configurations, storage options, sizing methodologies and control [J].
Chauhan, Anurag ;
Saini, R. P. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 38 :99-120
[6]   The technical and economic implications of integrating fluctuating renewable energy using energy storage [J].
Connolly, D. ;
Lund, H. ;
Mathiesen, B. V. ;
Pican, E. ;
Leahy, M. .
RENEWABLE ENERGY, 2012, 43 :47-60
[7]   Design of isolated hybrid systems minimizing costs and pollutant emissions [J].
Daud, Abdel-Karim ;
Ismail, Mahmoud S. .
RENEWABLE ENERGY, 2012, 44 :215-224
[8]   Analysis of change in electric energy cost with using renewable energy sources in Gokceada, Turkey: An island example [J].
Demiroren, A. ;
Yilmaz, U. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (01) :323-333
[9]   Optimization of control strategies for stand-alone renewable energy systems with hydrogen storage [J].
Dufo-Lopez, Rodolfo ;
Bernal-Agustin, Jose L. ;
Contreras, Javier .
RENEWABLE ENERGY, 2007, 32 (07) :1102-1126
[10]   Economic and environmental aspects Of the component sizing for a stand-alone building energy system: A case study [J].
Fux, Samuel F. ;
Benz, Michael J. ;
Guzzella, Lino .
RENEWABLE ENERGY, 2013, 55 :438-447