Distal radius fractures-Design of locking mechanism in plate system and recent surgical procedures

被引:11
作者
Inagaki, Katsunori [1 ]
Kawasaki, Keikichi [2 ]
机构
[1] Showa Univ, Sch Med, Dept Orthopaed Surg, Tokyo 142, Japan
[2] Showa Univ, Northern Yokohama Hosp, Dept Orthopaed Surg, Tokyo 142, Japan
关键词
INTRAARTICULAR FRACTURES; ARTHROSCOPIC REDUCTION; ASSISTED REDUCTION; INTERNAL-FIXATION; VOLAR; STABILITY; SCREWS; JOINT; WRIST;
D O I
10.1016/j.jos.2015.12.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recently, many studies have emphasized the importance of the comprehension of detailed functional anatomy of the distal forearm and wrist joint, and their biomechanics. A significant contribution which yields good functional outcomes of surgical treatment was the development of the locking plate technology; this technology has facilitated the improvement of the surgical technique for the fixation of fractures. This article reviews the locking mechanism and design of the fixation screws and plate, and the details of the surgical technique including the double-tired subchondral support procedure as it is applied to common fractures. Arthroscopic-assisted surgical procedures can be used to reduce the intra-articular fracture fragments after realignment of the distal radius with the locking plate. This technique is also useful at the time of fixation to assess soft tissue injury. The combination of arthroscopic-assisted reduction and locking plate fixation is now indicated for AO type C2 and C3 intra-articular comminuted fractures. (C) 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 262
页数:5
相关论文
共 24 条
[1]   Less invasive surgery with wrist arthroscopy for distal radius fracture [J].
Abe, Yukio ;
Yoshida, Koji ;
Tominaga, Yasuhiro .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (03) :398-404
[2]   The frequency and epidemiology of hand and forearm fractures in the United States [J].
Chung, KC ;
Spilson, SV .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05) :908-915
[3]   EXTERNAL PIN FIXATION FOR UNSTABLE COLLES FRACTURES [J].
COONEY, WP ;
LINSCHEID, RL ;
DOBYNS, JH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (06) :840-845
[4]   Flexor tendon injuries following locked volar plating of distal radius fractures [J].
Cross, Andrew W. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02) :164-167
[5]   Dry arthroscopy of the wrist:: Surgical technique [J].
del Pinal, Francisco ;
Garcia-Bernal, Francisco J. ;
Pisani, Daniele ;
Regalado, Javier ;
Ayala, Higinio ;
Studer, Alexis .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (01) :119-123
[6]   Technical Tips for (Dry) Arthroscopic Reduction and Internal Fixation of Distal Radius Fractures [J].
del Pinal, Francisco .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (10) :1694-1705
[7]   Intra-articular fractures of the distal aspect of the radius: Arthroscopically assisted reduction compared with open reduction and internal fixation [J].
Doi, K ;
Hattori, Y ;
Otsuka, K ;
Abe, Y ;
Yamamoto, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (08) :1093-1110
[8]   Intra-articular distal radius fractures: Arthroscopic assessment of radiographically assisted reduction [J].
Edwards, CC ;
Haraszti, CJ ;
McGillivary, GR ;
Gutow, AP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (06) :1036-1041
[9]   Kinematic and torque-related effects of dorsally angulated distal radius fractures and the distal radial ulnar joint [J].
Hirahara, H ;
Neale, PG ;
Lin, YT ;
Cooney, WP ;
An, KN .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (04) :614-621
[10]   An Anatomical Study of the Watershed Line on the Volar, Distal Aspect of the Radius: Implications for Plate Placement and Avoidance of Tendon Ruptures [J].
Imatani, Junya ;
Akita, Keiichi ;
Yamaguchi, Kumiko ;
Shimizu, Hirotaka ;
Kondou, Hidenori ;
Ozaki, Toshifumi .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (08) :1550-1554