Locked Intramedullary Total Wrist Arthrodesis: A Report of Three Patients With Distal Screw Migration

被引:4
作者
Kachooei, Amir R. [1 ]
Jones, Christopher M. [1 ]
Beredjiklian, Pedro [1 ]
机构
[1] Thomas Jefferson Univ, Orthopaed, Rothman Inst, Philadelphia, PA 19107 USA
关键词
implate; distal screw migration; intramedullary locked nail; arthrodesis; wrist; COMPLICATIONS;
D O I
10.7759/cureus.27420
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intramedullary (IM) fixation for the total wrist arthrodesis (TWA) is supposed to lower the hardware complication rate by eliminating soft tissue irritation. In this report, we present three patients with distal metacarpal screw migration requiring unplanned secondary surgery for screw removal in one patient while it was managed nonoperatively in the other two. All three patients had complete radiocarpal fusion by four months postop. There was no attempted third carpometacarpal (CMC) fusion in any of our patients. Screw migration was found between 1.5-3.5 months postop and remained stable until the final follow-up in the nonoperatively managed patients. One patient with screw removal continued to have mild tenderness over the third CMC, which was managed nonoperatively.
引用
收藏
页数:10
相关论文
共 15 条
[1]   Systematic Review of Total Wrist Arthroplasty and Arthrodesis in Wrist Arthritis [J].
Berber, Onur ;
Garagnani, Lorenzo ;
Gidwani, Sam .
JOURNAL OF WRIST SURGERY, 2018, 7 (05) :424-440
[2]   Hardware-Related Complications Following Radiocarpal Arthrodesis Using a Dorsal Plate [J].
Berling, Stephen E. ;
Kiefhaber, Thomas R. ;
Stern, Peter J. .
JOURNAL OF WRIST SURGERY, 2015, 4 (01) :56-60
[3]   WRIST ARTHRODESIS IN POSTTRAUMATIC ARTHRITIS - A COMPARISON OF 2 METHODS [J].
BOLANO, LE ;
GREEN, DP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (05) :786-791
[4]   ARTHRODESIS OF THE WRIST - COMPLICATIONS AND THEIR MANAGEMENT [J].
CLENDENIN, MB ;
GREEN, DP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (03) :253-257
[5]   Two-part surgical neck fractures of the proximal part of the humerus - A biomechanical evaluation of two fixation nchniques [J].
Edwards, Sara L. ;
Wilson, Nicole A. ;
Zhang, Li-Qun ;
Flores, Steven ;
Merk, Bradley R. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2258-2264
[6]  
Frank Jonathan M, 2015, Tech Hand Up Extrem Surg, V19, P133, DOI 10.1097/BTH.0000000000000093
[7]   Axial Micromotion Locking Plate Construct Can Promote Faster and Stronger Bone Healing in an Ovine Osteotomy Model [J].
Han, Zhihua ;
Wu, Jianhong ;
Deng, Guoying ;
Bi, Chun ;
Wang, Jiandong ;
Wang, Qiugen .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 8
[8]   Complications and Factors Associated with Reoperation following Total Wrist Fusion [J].
Hazewinkel, Merel Hazewinkel I. ;
Lans, Jonathan ;
Lunn, Kiera N. ;
Garg, Rohit ;
Eberlin, Kyle R. ;
Chen, Neal C. .
JOURNAL OF WRIST SURGERY, 2020, 9 (06) :498-508
[9]   Total wrist arthrodesis with wrist fusion rod in patients with rheumatoid arthritis [J].
Onuma, Kenji ;
Shintani, Ryosuke ;
Fujimaki, Hisako ;
Sukegawa, Koji ;
Kenmoku, Tomonori ;
Uchida, Kentaro ;
Takahira, Naonobu ;
Takaso, Masashi .
EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2015, 26 (01) :41-48
[10]   Locked Intramedullary Total Wrist Arthrodesis [J].
Orbay, Jorge L. ;
Feliciano, Eric ;
Orbay, Carolina .
JOURNAL OF WRIST SURGERY, 2012, 1 (02) :179-184