Real-time assessment of individual optimal CT perfusion acquisition time in patients with ischemic stroke

被引:0
作者
Filice, Silvano [1 ]
Pavarani, Antonio [2 ]
Cerasti, Davide [2 ]
机构
[1] Azienda Osped Univ Parma, Med Phys Unit, Parma, Italy
[2] Azienda Osped Univ Parma, Neuroradiol Unit, Parma, Italy
关键词
acquisition time; CT perfusion; ischemic stroke; optimization; CEREBRAL PERFUSION; SELECTION; ACCURACY;
D O I
10.1111/jon.13004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose This study aims to investigate the feasibility of a "real-time" estimate of the optimal CT perfusion (CTP) acquisition time (T-op) in ischemic stroke patients. Methods The arterial input function, the venous output function (VOF), and the time-attenuation curves of ischemic core and ischemic penumbra of 51 patients with acute ischemic stroke in anterior circulation were obtained. The curves were analyzed to determine for each patient the T-op value; additionally, several time parameters were derived from each waveform. The relationship between each of these parameters and T-op was investigated. Results We found a strong linear correlation between each time parameter derived from VOF curve and T-op, suggesting that the VOF waveform is rescaled from patient to patient without significant change in shape. Conclusions The linear correlation between T-op and the VOF time to peak is well suited to implement a new technique to automatically customize the patient's CTP acquisition time. The method does not require an additional dose of contrast medium and does not increase the overall study time, so its use would be desirable to decrease the average radiation dose.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 50 条
  • [21] Real-time ultrasound brain perfusion imaging with analysis of microbubble replenishment in acute MCA stroke
    Kern, Rolf
    Diels, Anna
    Pettenpohl, Johanna
    Kablau, Micha
    Brade, Joachim
    Hennerici, Michael G.
    Meairs, Stephen
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2011, 31 (08) : 1716 - 1724
  • [22] Automated CT perfusion imaging for acute ischemic stroke Pearls and pitfalls for real-world use
    Vagal, Achala
    Wintermark, Max
    Nael, Kambiz
    Bivard, Andrew
    Parsons, Mark
    Grossman, Aaron W.
    Khatri, Pooja
    NEUROLOGY, 2019, 93 (20) : 888 - 898
  • [23] Dynamic CT but Not Optimized Multiphase CT Angiography Accurately Identifies CT Perfusion Target Mismatch Ischemic Stroke Patients
    Tian, Huiqiao
    Chen, Chushuang
    Garcia-Esperon, Carlos
    Parsons, Mark W.
    Lin, Longting
    Levi, Christopher R.
    Bivard, Andrew
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [24] Review of Perfusion Imaging in Acute Ischemic Stroke From Time to Tissue
    Demeestere, Jelle
    Wouters, Anke
    Christensen, Soren
    Lemmens, Robin
    Lansberg, Maarten G.
    STROKE, 2020, 51 (03) : 1017 - 1024
  • [25] Real-Time Objective Evaluation of the Ischemic Stroke through pH-Responsive Fluorescence Imaging
    Yao, Shasha
    He, Chengbin
    Yuan, Pengcheng
    Xu, Xiaodan
    Zhou, Xiaoxuan
    Shen, Liyin
    Hu, Qiuhui
    Slater, Nigel K. H.
    Sun, Wenjing
    Shen, Youqing
    Hu, Hongjie
    Tang, Jianbin
    ADVANCED HEALTHCARE MATERIALS, 2023, 12 (09)
  • [26] Redefining CT perfusion-based ischemic core estimates for the ghost core in early time window stroke
    Koneru, Manisha
    Hoseinyazdi, Meisam
    Lakhani, Dhairya A.
    Greene, Cynthia
    Copeland, Karen
    Wang, Richard
    Xu, Risheng
    Luna, Licia
    Caplan, Justin M.
    Dmytriw, Adam A.
    Guenego, Adrien
    Heit, Jeremy J.
    Albers, Gregory W.
    Wintermark, Max
    Gonzalez, Luis F.
    Urrutia, Victor C.
    Huang, Judy
    Nael, Kambiz
    Leigh, Richard
    Marsh, Elisabeth B.
    Hillis, Argye E.
    Llinas, Rafael H.
    Yedavalli, Vivek S.
    JOURNAL OF NEUROIMAGING, 2024, 34 (02) : 249 - 256
  • [27] Agreement of three CT perfusion software packages in patients with acute ischemic stroke: A comparison with RAPID
    Lu, Qingqing
    Fu, Junyan
    Lv, Kun
    Han, Yan
    Pan, Yuning
    Xu, Yiren
    Zhang, Jun
    Geng, Daoying
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [28] Experimental Assessment of Real-Time Brain Stroke Monitoring via a Microwave Imaging Scanner
    Rodriguez-Duarte, David O.
    Origlia, Cristina
    Vasquez, Jorge A. Tobon
    Scapaticci, Rosa
    Crocco, Lorenzo
    Vipiana, Francesca
    IEEE OPEN JOURNAL OF ANTENNAS AND PROPAGATION, 2022, 3 : 824 - 835
  • [29] Quantitative collateral assessment evaluated by cerebral blood volume measured by CT perfusion in patients with acute ischemic stroke
    Hirai, Sakyo
    Tanaka, Yoji
    Sato, Hirotaka
    Kato, Koichi
    Kim, Yongson
    Yamamura, Toshihiro
    Sumita, Kazutaka
    Arai, Toshinari
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (07)
  • [30] Accuracy of Real-time Range Assessment for CORS
    Feng Wei
    Wu Xing
    Shao Jiani
    Yao Gang
    PROCEEDINGS OF 2010 INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND INDUSTRIAL ENGINEERING, VOLS I AND II, 2010, : 809 - 813