The Effects of Soft Contact Lens Wear on The Tear Film and Meibomian Gland Drop-Out and Visibility

被引:3
作者
Vicente Garcia-Marques, Jose [1 ]
Talens-Estarelles, Cristian [1 ]
Garcia-Lazaro, Santiago [1 ]
Cervino, Alejandro [1 ]
机构
[1] Univ Valencia, Dept Opt & Optometry & Vis Sci, C Dr Moliner 50, E-46100 Valencia, Spain
来源
LIFE-BASEL | 2022年 / 12卷 / 08期
关键词
contact lens; dry eye; meibomian glands; meibomian gland dysfunction; objective medical image analysis; ocular surface; tear film; TFOS INTERNATIONAL WORKSHOP; DYSFUNCTION REPORT; DISCOMFORT REPORT; OCULAR SURFACE; SUBCOMMITTEE; EPIDEMIOLOGY; OSMOLARITY; IMPACT;
D O I
10.3390/life12081177
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
As contact lens (CL) wear affects the ocular surface, this cross-sectional study aims to assess the effects of soft CL wear and its duration on the tear film and meibomian gland (MG) drop-out and visibility. Thirty non-CL wearers (22.5 +/- 2.3 years) and twenty-four soft CL wearers (23.8 +/- 2.2 years) participated in this study. The Keratograph 5M was used to assess the ocular surface. CL users were surveyed on years of CL wear and hours per week. MG visibility was assessed using a previously developed method based on analysing pixel intensity of meibographies. The CL group showed higher gland drop-out (p < 0.001) and lower gland visibility (p < 0.022). Gland drop-out was independently associated with CL wear (p = 0.006). When gland drop-out was excluded, the relative energy of pixel intensity values showed an independent association with CL wear (p = 0.005). Prolonged hours of CL wear were associated with higher dry eye symptoms and entropy of MGs (p < 0.029). A reduction in non-invasive keratograph break-up time was associated with using CLs for >= 8 years (p = 0.030). Overall, gland drop-out was higher and gland visibility lower in soft CL wearers. New gland visibility metrics might help to assess MGs in soft CL wearers quickly and objectively.
引用
收藏
页数:15
相关论文
共 47 条
  • [41] Direct visualization of tear film on soft contact lens using ultra-high resolution spectral domain optical coherence tomography
    Wang, Jianhua
    Jiao, Shuliang
    Ruggeri, Marco
    Wehbe, Hassan
    OPHTHALMIC TECHNOLOGIES XVIII, 2008, 6844
  • [42] Clinical Report: Midday Removal and Reinsertion of Soft Contact Lens Cannot Prevent Post-lens Tear-film Hyperosmolarity
    Kim, Young Hyun
    Thien Nguyen
    Lin, Meng C.
    Peng, Cheng-Chun
    Radke, Clayton J.
    OPTOMETRY AND VISION SCIENCE, 2022, 99 (08) : 652 - 654
  • [43] Effects of warm compress on tear film, blink pattern and Meibomian gland function in dry eyes after corneal refractive surgery
    Xueyi Zhou
    Yang Shen
    Jianmin Shang
    Xingtao Zhou
    BMC Ophthalmology, 21
  • [44] Effects of warm compress on tear film, blink pattern and Meibomian gland function in dry eyes after corneal refractive surgery
    Zhou, Xueyi
    Shen, Yang
    Shang, Jianmin
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [45] The effects of 2 week senofilcon-A silicone hydrogel contact lens daily wear on tear functions and ocular surface health status
    Dogru, Murat
    Ward, Samantha K.
    Wakamatsu, Tais
    Ibrahim, Osama
    Schnider, Cristina
    Kojima, Takashi
    Matsumoto, Yukihiro
    Ogawa, Junko
    Shimazaki, Jun
    Tsubota, Kazuo
    CONTACT LENS & ANTERIOR EYE, 2011, 34 (02) : 77 - 82
  • [46] Effect of sodium hyaluronate eye drop on tear film stability and tear secretion in patients with rigid gas-permeable contact lens-associated xerophthalmia
    Xu, Yaping
    Chen, Sheng
    Wu, Dingyong
    Yuan, Ziyun
    Liu, Xiaojun
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2023, 22 (12) : 2545 - 2551
  • [47] Evaluation of corneal topography, tear film function and conjunctival impression cytology after long-term scleral contact lens wear in keratoconus patients
    Uysal, Betul Seher
    Yaman, Derya
    Kalkan Akcay, Emine
    Kilicarslan, Aydan
    Sarac, Ozge
    Cagil, Nurullah
    SEMINARS IN OPHTHALMOLOGY, 2021, 36 (07) : 490 - 496