A deep red ratiometric fluorescent probe for accurate detection of peroxynitrite in mitochondria

被引:28
作者
Han, Rubing [1 ]
Shu, Wei [2 ]
Kang, Hao [1 ]
Duan, Qingxia [1 ]
Zhang, Xiaoli [1 ]
Liang, Chenlu [1 ]
Gao, Mengxu [1 ]
Xu, Liren [1 ]
Jing, Jing [1 ]
Zhang, Xiaoling [1 ]
机构
[1] Beijing Inst Technol, Sch Chem & Chem Engn,Beijing Key Lab Photoelect E, Minist Educ,Minist Ind & Informat Technol,Analyt, Key Lab Cluster Sci,Key Lab Med Mol Sci & Pharmac, Beijing 100081, Peoples R China
[2] Shandong Univ Technol, Sch Life Sci & Med, Zibo 255000, Peoples R China
基金
中国国家自然科学基金;
关键词
Fluorescent probe; Peroxynitrite; Ratio; Deep red; Mitochondria; IN-VIVO; SELECTIVE DETECTION; NITRIC-OXIDE; MODEL;
D O I
10.1016/j.aca.2022.339652
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Peroxynitrite (ONOO-) is widespread within living organisms and has been implicated in many physiological and pathological processes. Since ONOO- is mainly produced in mitochondria, accurate detection of ONOO- in mitochondria can help us understand its specific mechanism of action in the organism. Rather than single-wavelength emissive mitochondrial probes, ratiometric fluorescent probes with longer emission wavelength, large emission shift, and specific mitochondrial targeting properties are more likely to obtain a more accurate ONOO- content in mitochondria. To further avoid the interference by cytoplasmic ONOO-, we constructed a fluorescent probe MXMP with deep red emission and ratio properties, and it will be forbidden to enter the mitochondria after oxidation. In addition to its excellent selectivity and sensitivity, it shifted its fluorescence emission by up to 130 nm, with a detection limit of 84 nM. (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 41 条
[1]   APPARENT HYDROXYL RADICAL PRODUCTION BY PEROXYNITRITE - IMPLICATIONS FOR ENDOTHELIAL INJURY FROM NITRIC-OXIDE AND SUPEROXIDE [J].
BECKMAN, JS ;
BECKMAN, TW ;
CHEN, J ;
MARSHALL, PA ;
FREEMAN, BA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (04) :1620-1624
[2]   Benzopyrylium conjugated quinolone constructing 705 nm long wavelength emission for evaluation of sulfur dioxide in brain slices [J].
Chao, Jianbin ;
Wang, Zhuo ;
Zhang, Yongbin ;
Huo, Fangjun ;
Yin, Caixia .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
[3]   An activatable near-infrared fluorescent probe facilitated high-contrast lipophagic imaging in live cells [J].
Chen, Wen ;
Luo, Na ;
Zhang, Yuan ;
Tang, Li-Juan ;
Wang, Fenglin ;
Jiang, Jian-Hui .
CHEMICAL COMMUNICATIONS, 2021, 57 (69) :8664-8667
[4]   Selective Visualization of the Endogenous Peroxynitrite in an Inflamed Mouse Model by a Mitochondria-Targetable Two-Photon Ratiometric Fluorescent Probe [J].
Cheng, Dan ;
Pan, Yue ;
Wang, Lu ;
Zeng, Zebing ;
Yuan, Lin ;
Zhang, Xiaobing ;
Chang, Young-Tae .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2017, 139 (01) :285-292
[5]   Cooperation between reactive oxygen and nitrogen intermediates in killing of Rhodococcus equi by activated macrophages [J].
Darrah, PA ;
Hondalus, MK ;
Chen, QP ;
Ischiropoulos, H ;
Mosser, DM .
INFECTION AND IMMUNITY, 2000, 68 (06) :3587-3593
[6]   Visualization of ONOO- and Viscosity in Drug-Induced Hepatotoxicity with Different Fluorescence Signals by a Sensitive Fluorescent Probe [J].
Deng, Yingzhen ;
Feng, Guoqiang .
ANALYTICAL CHEMISTRY, 2020, 92 (21) :14667-14675
[7]   A chromene based fluorescence probe: Accurate detection of peroxynitrite in mitochondria, not elsewhere [J].
Fang, Ying ;
Chen, Ru-Xing ;
Qin, Hai-Feng ;
Wang, Jia-Jia ;
Zhang, Qi ;
Chen, Shaojin ;
Wen, Yong-Hong ;
Wang, Kun-Peng ;
Hu, Zhi-Qiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 334
[8]   Chemical Biology of Peroxynitrite: Kinetics, Diffusion, and Radicals [J].
Ferrer-Sueta, Gerardo ;
Radi, Rafael .
ACS CHEMICAL BIOLOGY, 2009, 4 (03) :161-177
[9]   Near-Infrared Mitochondria-Targetable Fluorescent Probe for High-Contrast Bioimaging of H2S [J].
Gong, Shengyi ;
Zheng, Zhoupeng ;
Guan, Xiaogang ;
Feng, Shumin ;
Feng, Guoqiang .
ANALYTICAL CHEMISTRY, 2021, 93 (14) :5700-5708
[10]   A mitochondria-targeting ratiometric fluorescent probe for imaging hydrogen peroxide with long-wavelength emission and large Stokes shift [J].
He, Long ;
Liu, Xingjiang ;
Zhang, Yun ;
Yang, Lei ;
Fang, Qian ;
Geng, Yani ;
Chen, Wenqiang ;
Song, Xiangzhi .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 276 :247-253