Improving Photoplethysmographic Measurements Under Motion Artifacts Using Artificial Neural Network for Personal Healthcare

被引:51
作者
Roy, Monalisa Singha [1 ]
Gupta, Rajarshi [1 ]
Chandra, Jayanta K. [2 ]
Das Sharma, Kaushik [1 ]
Talukdar, Arunansu [3 ]
机构
[1] Univ Calcutta, Dept Appl Phys, Elect Engn Sect, Kolkata 700009, India
[2] Purulia Govt Engn Coll, Dept Elect Engn, Purulia 723103, India
[3] Med Coll & Hosp, Dept Med, Kolkata 700073, India
关键词
Beat quality assessment; deep auto-encoder (DAE); motion artifacts (MA); particle swarm optimization (PSO); photoplethysmography (PPG); signal-to-noise ratio (SNR) improvement; SIGNAL QUALITY ESTIMATION; HEART-RATE; REDUCTION; TIME; ALGORITHM; REMOVAL;
D O I
10.1109/TIM.2018.2829488
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photoplethysmographic (PPG) measurements are susceptible to motion artifacts (MA) due to movement of the peripheral body parts. In this paper, we present a new approach to identify the MA corrupted PPG beats and then rectify the beat morphology using artificial neural network (ANN). Initially, beat quality assessment was done to identify the clean PPG beats by a pretrained feedback ANN to generate a reference beat template for each person. The PPG data were decomposed using principal component analysis (PCA) and reconstructed using fixed energy retention. A weight coefficient was assigned for each PPG sample in such a way that when they are multiplied, the modified beat morphology matches the reference template. A particle swarm optimization-based technique was utilized to select the best weight vector coefficients to tune another feedback ANN, fed with a set of significant features generated by an auto-encoder from PCA reconstructed data. For real-time implementation, this pretrained ANN was operated in feed-forward mode to directly generate the weight vectors for any subsequent measurements of PPG. The method was validated with PPG data collected from 55 human subjects. An average root-mean-square error of 0.28 and signal-to-noise ratio improvement of 14.54 dB were obtained, with an average improvement of 36% and 47% measurement accuracies on crest time and systolic to diastolic peak height ratio, respectively. With the IEEE Signal Processing Cup 2015 challenge database, Pearson's correlation coefficient between PPG-estimated and ECG-derived heart rates was 0.990. The proposed method can be useful for personal health monitoring applications.
引用
收藏
页码:2820 / 2829
页数:10
相关论文
共 43 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   Photoplethysmography assessments in cardiovascular disease [J].
Allen, John ;
Overbeck, Klaus ;
Stansby, Gerard ;
Murray, Alan .
MEASUREMENT & CONTROL, 2006, 39 (03) :80-83
[3]   Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis [J].
Couceiro, R. ;
Carvalho, P. ;
Paiva, R. P. ;
Henriques, J. ;
Muehlsteff, J. .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) :2369-2388
[4]   Assessment of cardiovascular function from multi-Gaussian fitting of a finger photoplethysmogram [J].
Couceiro, Ricardo ;
Carvalho, P. ;
Paiva, R. P. ;
Henriques, J. ;
Quintal, I. ;
Antunes, M. ;
Muehlsteff, J. ;
Eickholt, C. ;
Brinkmeyer, C. ;
Kelm, M. ;
Meyer, C. .
PHYSIOLOGICAL MEASUREMENT, 2015, 36 (09) :1801-1825
[5]  
Davoudi K, 2013, COMPUT CARDIOL CONF, V40, P265
[6]   Autonomous Wearable System for Vital Signs Measurement With Energy-Harvesting Module [J].
Dionisi, Alessandro ;
Marioli, Daniele ;
Sardini, Emilio ;
Serpelloni, Mauro .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (06) :1423-1434
[7]   An Algorithm for Real-Time Pulse Waveform Segmentation and Artifact Detection in Photoplethysmograms [J].
Fischer, Christoph ;
Doemer, Benno ;
Wibmer, Thomas ;
Penzel, Thomas .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (02) :372-381
[8]   Minimum Noise Estimate Filter: A Novel Automated Artifacts Removal Method for Field Potentials [J].
Foodeh, Reza ;
Khorasani, Abed ;
Shalchyan, Vahid ;
Daliri, Mohammad Reza .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (08) :1143-1152
[9]  
Ghosal P, 2015, 2015 IEEE INTERNATIONAL CONFERENCE ON RESEARCH IN COMPUTATIONAL INTELLIGENCE AND COMMUNICATION NETWORKS (ICRCICN), P114, DOI 10.1109/ICRCICN.2015.7434220
[10]   Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement [J].
He, Xiaochuan ;
Goubran, Rafik A. ;
Liu, Xiaoping P. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (06) :1431-1439