Analysis of peroxide value in olive oils with an easy and green method

被引:22
作者
Longobardi, Francesco [1 ]
Contillo, Francesco [1 ]
Catucci, Lucia [1 ,2 ]
Tommasi, Luca [3 ]
Caponio, Francesco [4 ]
Paradiso, Vito Michele [4 ,5 ]
机构
[1] Univ Bari, Dept Chem, Via Orabona 4, I-70126 Bari, Italy
[2] CNR IPCF Inst Phys & Chem Proc, Bari Unit, Via Orabona 4, I-70126 Bari, Italy
[3] BonassisaLab, SS 16 Km 684,300, I-71122 Foggia, Italy
[4] Univ Bari, Dept Soil Plant & Food Sci, Via Amendola 165-A, I-70126 Bari, Italy
[5] Univ Salento, Dept Biol & & Environm Sci & Technol, Food Sci Lab, I-73100 Lecce, Italy
关键词
Hydroperoxides; Spectrophotometric method; Virgin olive oil; Green analytical chemistry; FTIR SPECTROSCOPY; EDIBLE OILS;
D O I
10.1016/j.foodcont.2021.108295
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A green, easy-to-use, and sensitive spectrophotometric iodide-dependant method for the quantitative determination of the lipidic hydroperoxides in virgin olive oils was developed. Virgin olive oils were added with 0.5% HCl-ethanol, with a saturated KI solution and, after incubation, the resulting solution was filtered. Hydroperoxides were determined indirectly by reading the absorbance of the generated triiodide at 350 nm; the total time of analysis was about 7 min. A good linearity (with correlation coefficient (r) of 0.9997) of the calibration curve was obtained with purified olive oil spiked with tert-butylhydroperoxide at levels ranging from 1.0 to 10.0 meqO2/kg, with variation coefficients less than 5% (n = 3) and limit of detection and quantification of 0.3 and 0.9 meqO2/kg, respectively. Results obtained with the spectrophotometric method showed good correlation with those obtained with the official method with a r of 0.9819 confirming the reliability of the developed method.
引用
收藏
页数:6
相关论文
共 19 条
[1]  
CodexAlimentarius, 2017, CODEX, V91, P1689, DOI [10.1017/CBO9781107415324.004, DOI 10.1017/CBO9781107415324.004]
[2]  
Dobarganes MC, 2002, EUR J LIPID SCI TECH, V104, P420, DOI 10.1002/1438-9312(200207)104:7<420::AID-EJLT420>3.0.CO
[3]  
2-N
[4]  
EEC Commission, 1991, EEC REGULATION 25689
[5]   Traceable measurements of the static permittivity of dielectric reference liquids over the temperature range 5-50 °C [J].
Gregory, AP ;
Clarke, RN .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (07) :1506-1516
[6]  
Kiritsakis A, 2002, EUR J LIPID SCI TECH, V104, P628, DOI 10.1002/1438-9312(200210)104:9/10<628::AID-EJLT628>3.0.CO
[7]  
2-1
[8]   A SENSITIVE SPECTROPHOTOMETRIC METHOD FOR LIPID HYDROPEROXIDE DETERMINATION [J].
LOVAAS, E .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1992, 69 (08) :777-783
[9]  
Miller I, 2014, JE FREUNDS MATH STAT
[10]   Everything Should Be as Simple as It Can Be. But Not Simpler. Does Food Lipid Oxidation Require an Omics Approach? [J].
Paradiso, Vito M. ;
Pasqualone, Antonella ;
Summo, Carmine ;
Caponio, Francesco .
EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY, 2018, 120 (07)