Performance of Large Spacer Versus Nebulizer T-Piece in Single-Limb Noninvasive Ventilation

被引:43
作者
Harb, Hadeer S. [1 ]
Elberry, Ahmed A. [2 ]
Rabea, Hoda [1 ]
Fathy, Maha [3 ]
Abdelrahim, Mohamed E. A. [1 ,4 ]
机构
[1] Beni Suef Univ, Fac Pharm, Clin Pharm Dept, Bani Suwayf, Egypt
[2] Beni Suef Univ, Fac Med, Clin Pharmacol Dept, Bani Suwayf, Egypt
[3] Beni Suef Univ, Fac Med, Resp Dept, Bani Suwayf, Egypt
[4] Modern Univ Technol & Informat, Fac Pharm, Clin Pharm Dept, Cairo, Egypt
关键词
pMDI; salbutamol; NIV; COPD; lung; bioavailability nebulizer; METERED-DOSE INHALER; VIBRATING MESH NEBULIZER; IN-VITRO; AEROSOL DELIVERY; JET NEBULIZER; AERODYNAMIC CHARACTERISTICS; LUNG DEPOSITION; SYSTEMIC BIOAVAILABILITY; SALBUTAMOL; INHALATION;
D O I
10.4187/respcare.05976
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Predosing patients with COPD with salbutamol by using a pressurized metered-dose-inhaler (pMDI) as a bronchodilator was hypothesized to improve the distribution of the subsequent nebulized dose. This study determined the effect of a pMDI preliminary bronchodilator dose on the aerosol delivered by a mesh nebulizer during single-limb noninvasive ventilation. METHODS: Twelve subjects with COPD who received noninvasive ventilation were enrolled in a randomized, open-label, urinary pharmacokinetic study. A bi-level ventilator with a dry single-limb circuit and the fixed expiratory port was set in the spontaneous mode, with initial inspiratory and expiratory pressures of 20 and 5 cm H2O respectively, a 1:3 inspiratory-expiratory ratio, and 15 breaths/min. Salbutamol was administered via a mesh nebulizer with a large spacer or T-piece placed between the fixed-orifice expiratory valve and the oronasal mask. In vivo dosing methods were randomized for days 1,3, and 5 of the study. On each day, a 1-mL respirable solution that contained 5,000 mu ptg salbutamol was nebulized by using a mesh nebulizer with 3 setting: (1) T-piece, (2) large spacer, and (3) large spacer plus pMDI. Only with the large spacer plus pMDI setting, 2 pMDI doses, which contained 100 mu g salbutamol each, were actuated before nebulization. Urine samples were collected at 0.5 h (as an index of pulmonary bioavailability) and pooled up to 24 h after dosing (as an index of systemic absorption). On day 2, ex vivo studies were performed for the 3 setting with salbutamol collected onto filters placed before the mask. The drug was eluted from the filters and analyzed to determine the inhaled dose. RESULTS: A large spacer plus pMDI showed a trend to deliver a higher fraction (percentage of nominal dose) of both ex vivo filters and 0.5-h urinary salbutamol. The 0.5-h urinary salbutamol excreted with a large spacer plus pMDI (1.99%) was larger than with the T-piece (1.73%) and large spacer (1.78%). This trend did not extend to the 24-h levels, in which bioavailability with the large spacer plus pMDI (49.9%) was lower than with the T-piece (52.8%) and with the large spacer (54.3%). However, no differences were significant. CONCLUSIONS: The T-piece and large spacer were equally efficient for salbutamol delivery from the mesh nebulizer in patients with COPD and on single-limb noninvasive ventilation. Adding a preliminary bronchodilator dose by pMDI prenebulization showed a trend toward greater pulmonary bioavailability of nebulized salbutamol and may be worth considering to maximize delivery of salbutamol to patients who are severely ill.
引用
收藏
页码:1360 / 1369
页数:10
相关论文
共 46 条
[1]   Aerodynamic characteristics of nebulized terbutaline sulphate using the Andersen Cascade Impactor compared to the Next Generation Impactor [J].
Abdelrahim, Mohamed E. .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2011, 16 (02) :137-145
[2]   In-vitro characterisation of the nebulised dose during non-invasive ventilation [J].
Abdelrahim, Mohamed E. ;
Plant, Paul ;
Chrystyn, Henry .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2010, 62 (08) :966-972
[3]   Emitted dose and lung deposition of inhaled terbutaline from Turbuhaler at different conditions [J].
Abdelrahim, Mohamed E. .
RESPIRATORY MEDICINE, 2010, 104 (05) :682-689
[4]   Aerodynamic Characteristics of Nebulized Terbutaline Sulphate Using the Next Generation Impactor (NGI) and CEN Method [J].
Abdelrahim, Mohamed E. ;
Chrystyn, Henry .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2009, 22 (01) :19-28
[5]   Modeling and Optimization of Terbutaline Emitted from a Dry Powder Inhaler and Influence on Systemic Bioavailability Using Data Mining Technology [J].
Ali, Ahmed Mahmoud Abdelhaleem ;
Abdelrahim, Mohamed Emam A. .
JOURNAL OF PHARMACEUTICAL INNOVATION, 2014, 9 (01) :38-47
[6]  
[Anonymous], 2017, J RESPIR MED LUNG DI
[7]  
[Anonymous], [No title captured]
[8]   Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study [J].
Ari, Arzu ;
Harwood, Robert J. ;
Sheard, Meryl M. ;
Fink, James B. .
Respiratory Care, 2015, 60 (11) :1570-1574
[9]   Albuterol Delivery by 4 Different Nebulizers Placed in 4 Different Positions in a Pediatric Ventilator In Vitro Model [J].
Berlinski, Ariel ;
Willis, J. Randy .
RESPIRATORY CARE, 2013, 58 (07) :1124-1133
[10]  
Boukhettala N., 2012, EUR RESP, V40, pP2012