Dose and image quality optimization in neonatal radiography

被引:37
|
作者
Dougeni, E. D.
Delis, H. B.
Karatza, A. A.
Kalogeropoulou, C. P.
Skiadopoulos, S. G.
Mantagos, S. P.
Panayiotakis, G. S. [1 ]
机构
[1] Univ Patras, Dept Med Phys, Sch Med, Patras 26500, Greece
[2] Univ Patras, Sch Med, Dept Paediat, Patras 26500, Greece
[3] Univ Patras, Sch Med, Dept Radiol, Patras 26500, Greece
来源
BRITISH JOURNAL OF RADIOLOGY | 2007年 / 80卷 / 958期
关键词
D O I
10.1259/bjr/77948690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In a special care baby unit, neonates, mainly premature, encounter serious to life-threatening diseases, the timely diagnosis and treatment of which may require a large number of radiographs. Increased neonatal radiosensitivity and longer life expectancy increase the risk of radiation-induced cancer, which emphasizes the importance of minimizing dose while maintaining clinically satisfactory image quality. An optimization study on radiation dose and image quality in neonatal radiography is presented. Neonates were categorized into four groups depending on birthweight. For a total of 378 chest and chest-abdomen radiographs, exposure parameters were recorded. Entrance surface dose (ESD) was estimated and dose-area product (DAP) was measured. Image quality evaluation was performed by two observers and was based on the visibility of certain anatomical features and catheters placed during treatment using a five-grade scale. ESD values increased with neonatal weight and demonstrated wide variation (16.4-76.9 mu Gy, mean 38.2 mu Gy). A wide variation was also observed in DAP values (1.2-15.0 mGycm(2), mean 7.2 mGycm(2)). Image quality evaluation revealed the feasibility of achieving a diagnostically satisfactory image (score > 70%) using both low and high tube voltage techniques, with the latter resulting in reduced ESDs. The majority of estimated ESDs are in accordance with the reference level of 50 mu Gy recommended by the National Radiological Protection Board for neonatal radiography. The results suggest that the use of high tube voltage techniques could result in further reductions in neonatal dose, without image quality degradation, underlying the requirement for establishing standard examination protocols for neonatal radiography with respect to neonatal weight.
引用
收藏
页码:807 / 815
页数:9
相关论文
共 50 条
  • [1] Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography
    John E. Aldrich
    Emerenciana Duran
    Pat Dunlop
    John R. Mayo
    Journal of Digital Imaging, 2006, 19 : 126 - 131
  • [2] Neonatal radiography: Radiation dose in association with image quality
    Dougeni, E
    Karatza, A
    Delis, H
    Kalogeropoulou, C
    Panayiotakis, G
    Mantagos, S
    PEDIATRIC RESEARCH, 2005, 58 (02) : 387 - 387
  • [3] Optimization of dose and image quality for computed radiography and digital radiography
    Aldrich, JE
    Duran, E
    Dunlop, P
    Mayo, JR
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (02) : 126 - 131
  • [4] Neonatal radiography: radiation dose in association with image quality: 192
    Dougeni E.
    Karatza A.
    Delis H.
    Kalogeropoulou C.
    Panayiotakis G.
    Mantagos S.
    Pediatric Research, 2005, 58 (2) : 387 - 387
  • [5] Optimisation of radiation dose and image quality in mobile neonatal chest radiography
    Hinojos-Armendariz, V. I.
    Mejia-Rosales, S. J.
    Franco-Cabrera, M. C.
    RADIOGRAPHY, 2018, 24 (02) : 104 - 109
  • [6] Optimization of dose and image quality in pediatrics chest digital radiography
    Deevband, Mohammad Reza
    Rahmani, Fereshteh
    Bardar, Meisam Ebrahimi
    Ghorbani, Mahdi
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 443 - 449
  • [7] Dose Optimization and Image Quality in Digital Radiography: A Review Article
    Barai, Juhi
    Tivaskar, Suhas
    Sable, Apeksha
    Luharia, Anurag
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 (03) : 1076 - 1080
  • [8] Dose optimization and image quality measurement in digital abdominal radiography
    Karal, Omer
    Tokgoz, Nazime
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [9] A phantom for dose-image quality optimization in chest radiography
    Vassileva, J
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (898): : 837 - 842
  • [10] Optimization of image quality and minimization of radiation dose for chest computed radiography
    Kong, X.
    Liu, H.
    Rong, X.
    Sweet, C.
    Yang, Z.
    Edwards, S.
    Thai, T.
    Thomas, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2016 - 2016