Closure of a moderately large atrial septal defect with a self-fabricated fenestrated amplatzer septal occluder in an 85-year-old patient with reduced diastolic elasticity of the left ventricle

被引:42
作者
Holzer, R [1 ]
Cao, QL [1 ]
Hijazi, ZM [1 ]
机构
[1] Univ Chicago, Childrens Hosp, Dept Pediat, Cardiol Sect, Chicago, IL 60637 USA
关键词
fenestrated Amplatzer device; atrial septal defect; adult congenital heart disease;
D O I
10.1002/ccd.20315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Percutaneous closure of an atrial septal defect (ASD) in the elderly with reduced diastolic elasticity of the left ventricle poses a significant management challenge. We report on the case of an 85-year-old patient who was admitted for percutaneous device closure of a moderately large secundum atrial septal defect. Hemodynamic evaluation documented an increase in left atrial pressure from a mean of 12 mm Hg to a mean of 32 mm Hg after balloon test occlusion of the ASD. Two months later, after adequate pretreatment with diuretics and afterload-reducing substances, he underwent successful closure of the ASD using a self-fabricated fenestrated Amplatzer septal occluder, which resulted in a postimplantation left atrial pressure of a mean of 18 mm Hg. Recovery was unremarkable and the fenestration has remained patent for 3 months since implantation of the device. This unique case highlights the feasibility of using a self-fabricated fenestrated Amplatzer septal occluder to close interatrial communications in elderly patients with diastolic dysfunction of the left ventricle. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:513 / 518
页数:6
相关论文
共 10 条
[1]   LEFT-VENTRICULAR DISTENSIBILITY AND PASSIVE ELASTIC STIFFNESS IN ATRIAL SEPTAL-DEFECT [J].
BOOTH, DC ;
WISENBAUGH, T ;
SMITH, M ;
DEMARIA, AN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (05) :1231-1236
[2]   Fenestrated amplatzer device for percutaneous creation of interatrial communication in patients after Fontan operation [J].
Chatrath, R ;
Cabalka, AK ;
Driscoll, DJ ;
Hagler, DJ .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (01) :88-93
[3]   Early and late complications associated with transcatheter occlusion of secundum atrial septal defect [J].
Chessa, M ;
Carminati, M ;
Butera, G ;
Bini, RM ;
Drago, M ;
Rosti, L ;
Giamberti, A ;
Pomè, G ;
Bossone, E ;
Frigiola, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) :1061-1065
[4]   Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults - Results of a multicenter nonrandomized trial [J].
Du, ZD ;
Hijazi, ZM ;
Kleinman, CS ;
Silverman, NH ;
Larnitz, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (11) :1836-1844
[5]   Transcatheter closure of atrial septal defects without fluoroscopy - Feasibility of a new method [J].
Ewert, P ;
Berger, F ;
Daehnert, I ;
van Wees, J ;
Gittermann, M ;
Abdul-Khaliq, H ;
Lange, PE .
CIRCULATION, 2000, 101 (08) :847-849
[6]  
Ewert P, 2001, CATHETER CARDIO INTE, V52, P177, DOI 10.1002/1522-726X(200102)52:2<177::AID-CCD1043>3.3.CO
[7]  
2-7
[8]   LEFT-VENTRICULAR FUNCTION IN ATRIAL SEPTAL-DEFECT - ARE INTERVENTRICULAR INTERACTIONS STILL TOO COMPLEX TO PERMIT DEFINITIVE ANALYSIS [J].
FERLINZ, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (05) :1237-1240
[9]   Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: a single centre study in 236 consecutive patients [J].
Fischer, G ;
Stieh, J ;
Uebing, A ;
Hoffmann, U ;
Morf, G ;
Kramer, HH .
HEART, 2003, 89 (02) :199-204
[10]   Creation of an intra-atrial communication with a new amplatzer shunt prosthesis: Preliminary results in a swine model [J].
Kong, H ;
Gu, XP ;
Titus, JL ;
Kim, TH ;
Urness, M ;
Han, YM ;
Hessliein, P ;
Bass, J ;
Chun, M ;
Hunter, DW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (02) :267-271