Determination of ultra trace levels of copper in food samples by a highly sensitive adsorptive stripping voltammetric method

被引:53
作者
Abbasi, Shahryar [1 ]
Khani, Hossein [1 ]
Tabaraki, Reza [1 ]
机构
[1] Ilam Univ, Fac Sci, Dept Chem, Ilam, Iran
关键词
Copper; Thiosemicarbazide; Adsorptive stripping voltammetry; Food; BISMUTH; LEAD; MOLYBDENUM; SEAWATER; CADMIUM; COMPLEX; CU(II);
D O I
10.1016/j.foodchem.2010.03.043
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new method is presented, for the determination of copper, based on adsorptive stripping voltammetry of the complex of copper with thiosemicarbazide at a hanging mercury drop electrode (HMDE). The most suitable operating conditions and parameters, such as pH, accumulation potential, deposition time, ligand concentration and scan rate, were selected. The calibration graph for copper (II) was linear over the concentration range 0.01-90.0 ng/ml; the detection limit of the method was 0.007 ng/ml. The interferences of some common ions were studied and the method was found suitable for the determination of copper (II) in rice, tea, tomato, blood and water samples. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods other than adsorptive stripping voltammetry for the determination of copper. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [41] Determination of Trace Copper in Water Samples by Anodic Stripping Voltammetry at Gold Microelectrode
    Zhuang, Jianmei
    Zhang, Li
    Lu, Wenjing
    Shen, Dazhong
    Zhu, Rilong
    Pan, Dawei
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10): : 4690 - 4699
  • [42] Highly selective-cathodic stripping voltammetric determination of copper with α-benzylmonooxime
    Ensafi, AA
    Abbasi, S
    [J]. MICROCHEMICAL JOURNAL, 2000, 64 (02) : 195 - 200
  • [43] Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead
    Jovanovski, V.
    Hrastnik, N. I.
    Hocevar, S. B.
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2015, 57 : 1 - 4
  • [44] Catalytic adsorptive stripping voltammetry determination of ultra trace amount of tungsten using factorial design for optimization
    Zarei, K.
    Atabati, M.
    Shoari, R.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (05) : 518 - 524
  • [45] Application of adsorptive stripping voltammetry to the determination of trace levels of titanium in mice organs
    Pereira, MD
    Pereira, MD
    [J]. ELECTROANALYSIS, 1999, 11 (16) : 1207 - 1210
  • [46] In-situ prepared copper film electrode for adsorptive stripping voltammetric detection of trace Ni(II)
    Hrastnik, Nana I.
    Jovanovski, Vasko
    Hocevar, Samo B.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 307 (307):
  • [47] Cathodic Adsorptive Stripping Voltammetric Determination of Trace Amounts of Uranium (VI) Based on Its Complex with Chromazorul-S
    Mohadesi, Alireza
    Hosseinzadeh, Laleh
    Abbasi, Shahriar
    Esfandyarpour, Mohammad
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2009, 92 (03) : 927 - 932
  • [48] Adsorptive Cathodic Stripping Voltammetric Method for Determination of Gallium Using an In Situ Plated Lead Film Electrode
    Grabarczyk, Malgorzata
    Wasag, Joanna
    [J]. ELECTROANALYSIS, 2015, 27 (11) : 2596 - 2600
  • [49] Adsorptive cathodic stripping voltammetric determination of indapamide as copper complex at a hanging mercury drop electrode
    Radi, A
    [J]. CHEMIA ANALITYCZNA, 2003, 48 (02): : 273 - 281
  • [50] Simultaneous Determination of Ultra Trace of Uranium and Cadmium by Adsorptive Cathodic Stripping Voltammetry Using H-Point Standard Addition Method
    Ahmadi, Farhad
    Bakhshandeh-Saraskanrood, Fatemeh
    [J]. ELECTROANALYSIS, 2010, 22 (11) : 1207 - 1216