Radiostereometric analysis of early anatomical changes following medial opening wedge high tibial osteotomy

被引:7
作者
Teeter, Matthew G. [1 ]
Leitch, Kristyn M. [2 ]
Pape, Dietrich [3 ]
Yuan, Xunhua [4 ]
Birmingham, Trevor B. [2 ,5 ]
Giffin, J. Robert [1 ,2 ]
机构
[1] Univ Western Ontario, Dept Surg, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Fowler Kennedy Sport Med Clin, Wolf Orthopaed Biomech Lab, London, ON, Canada
[3] Ctr Hosp Luxembourg, Dept Orthopaed Surg, Luxembourg, Luxembourg
[4] Univ Western Ontario, Robarts Res Inst, Imaging Res Labs, London, ON, Canada
[5] Univ Western Ontario, Fac Hlth Sci, Sch Phys Therapy, London, ON, Canada
关键词
High tibial osteotomy; Radiostereometric analysis; FIXATION STABILITY; SLOPE;
D O I
10.1016/j.knee.2014.10.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The objective of this study was to use radiostereometric analysis (RSA) to evaluate the anatomical changes that occur in the tibia immediately after surgical correction with medial opening wedge high tibial osteotomy (HTO), and the changes that occur over the course of the first twelve weeks of osseous union. Methods: Patients included nine males and one female, with a mean age of 49.0 +/- 5.5 years and mean BMI of 28.4 +/- 3.8 kg/m(2). The patients underwent HTO using a non-locking plate. RSA marker beads were inserted in the tibia, femur, and patella. RSA exams were first obtained intra-operatively prior to the osteotomy, and subsequently at one, two, four, six, and twelve weeks postoperatively. Results: Patients were corrected from a mean alignment preoperatively of 8.6 +/- 2.5 degrees to 0.3 +/- 1.9 degrees postoperatively, with a mean osteotomy of 12.5 +/- 3.6 mm. Immediate tibia changes surrounding the osteotomy site included 9.2 +/- 2.4 degrees of valgus rotation and 6.2 +/- 2.0 mm of distal translation. Secondary motions included 2.5 +/- 2.4 degrees of internal rotation of the distal tibia, 1.8 +/- 1.4 mm of posterior movement of the femur, and 8.5 +/- 3.4 mm of patella baja. Micromotion between the proximal and distal tibial segments decreased over time. Conclusion: The results suggest that subtle changes to the anatomy occur, beyond what is intended with the procedure, but partial corrections of these phenomena occurred over the twelve weeks. Micromotion surrounding the osteotomy site decreased with osseous union. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [21] Effect of Tibial Cut Planes and Hinge Axes on Medial Opening Wedge High Tibial Osteotomy
    Park, Byoung-Keon
    Lee, Ho-sang
    Kim, Jay-Jung
    Kim, Cheol-Woong
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2011, 35 (08) : 835 - 846
  • [22] How to achieve an optimal alignment in medial opening wedge high tibial osteotomy?
    Byoung Youl Kang
    Do Kyung Lee
    Hyeon Soo Kim
    Joon Ho Wang
    Knee Surgery & Related Research, 34
  • [23] Early results of medial opening wedge high tibial osteotomy using an intraosseous implant with accelerated rehabilitation
    Morris, Jodie
    Grant, Andrea
    Kulkarni, Rohit
    Doma, Kenji
    Harris, Alicia
    Hazratwala, Kaushik
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (01) : 147 - 156
  • [24] Early results of medial opening wedge high tibial osteotomy using an intraosseous implant with accelerated rehabilitation
    Jodie Morris
    Andrea Grant
    Rohit Kulkarni
    Kenji Doma
    Alicia Harris
    Kaushik Hazratwala
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 147 - 156
  • [25] Effect of Medial Opening Wedge High Tibial Osteotomy on Intraarticular Knee and Ankle Contact Pressures
    Suero, Eduardo M.
    Sabbagh, Yaman
    Westphal, Ralf
    Hawi, Nael
    Citak, Musa
    Wahl, Friedrich M.
    Krettek, Christian
    Liodakis, Emmanouil
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (04) : 598 - 604
  • [26] Return to Work Following Isolated Opening Wedge High Tibial Osteotomy
    Agarwalla, Avinesh
    Christian, David R.
    Liu, Joseph N.
    Garcia, Grant H.
    Redondo, Michael L.
    Yanke, Adam B.
    Cole, Brian J.
    CARTILAGE, 2021, 12 (04) : 468 - 474
  • [27] Return to sport following isolated opening wedge high tibial osteotomy
    Liu, Joseph N.
    Agarwalla, Avinesh
    Garcia, Grant H.
    Christian, David R.
    Redondo, Michael L.
    Yanke, Adam B.
    Cole, Brian J.
    KNEE, 2019, 26 (06) : 1306 - 1312
  • [28] Tibial nerve neuropathy following medial opening-wedge high tibial osteotomy—case report of a rare technical complication
    Shin Y.-S.
    Sim H.-B.
    Yoon J.-R.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 563 - 567
  • [29] Changes in sagittal and axial plane alignment in medial opening wedge high tibial osteotomy: a prospective observational study
    Pragadeeshwaran J.
    Paul S.
    Moge N.M.
    Goyal T.
    MUSCULOSKELETAL SURGERY, 2023, 107 (1) : 115 - 121
  • [30] The effect of biplane medial opening wedge high tibial osteotomy on patellofemoral joint indices
    Yang, Jae-Hyuk
    Lee, Suk-Ha
    Nathawat, Kuldeep Singh
    Jeon, Seung-Hyub
    Oh, Kwang-Jun
    KNEE, 2013, 20 (02) : 128 - 132