Patient dose due to colon examination: Dose assessment and results from a survey in the Netherlands

被引:30
作者
Geleijns, J
Broerse, JJ
Shaw, MPC
Schultz, FW
Teeuwisse, W
vanUnnik, JG
Zoetelief, J
机构
[1] UNIV LEIDEN HOSP,DEPT DIAGNOST RADIOL,NL-2333 ZA LEIDEN,NETHERLANDS
[2] NEDERLANDSE ORG TOEGEPAST NAT WETENSCHAPPELIJK ON,CTR RADIOL PROTECT & DOSIMETRY,RIJSWIJK,NETHERLANDS
[3] ONZE LIEVE VROUW HOSP,DEPT DIAGNOST RADIOL,AMSTERDAM,NETHERLANDS
关键词
barium enema examination; colon; radiography; dosimetry; radiations; exposure to patients and personnel;
D O I
10.1148/radiology.204.2.9240552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the effective dose to the patient during radiographic colon examination. MATERIALS AND METHODS: The integral dose-area product was measured during colon examination in 1,733 patients aged 18-94 years. The effective dose was estimated from the dose-area product through computer simulations of radiation transport in anthropomorphic phantoms. The relation between patient dose and imaging or radiographic technique was considered. Patient dose from a biphasic colon examination was compared to that from a double-contrast examination. RESULTS: The factors for converting dose-area product to effective dose were 0.29 mSv . Gy(-1) . cm(-2) and 0.27 mSv . Gy(-1) . cm(-2) for the biphasic and the double-contrast studies, respectively. The average dose-area product for the biphasic colon examination was 21 Gy . cm(2), of which 13 Gy . cm(2) was attributed to the double-contrast views. The average dose-area product was 29 Gy . cm(2) (range, 18-53 Gy . cm(2)); the average effective dose was 4.7 mSv (range, 2.7-8.4 mSv). CONCLUSION: Careful selection of the radiologic technique resulted in a surprisingly low dose during the biphasic colon examination. It is recommended that additional filtration of at least 0.1-mm copper be applied and that a screen-film combination with a speed class of at least 400 be used. Dose reduction when using digital techniques is often not realized in clinical practice.
引用
收藏
页码:553 / 559
页数:7
相关论文
共 14 条
  • [1] COLON POLYPS AND CARCINOMAS - PROSPECTIVE COMPARISON OF THE SINGLE-CONTRAST AND DOUBLE-CONTRAST EXAMINATION IN THE SAME PATIENTS
    DEROOS, A
    HERMANS, J
    SHAW, PC
    KROON, H
    [J]. RADIOLOGY, 1985, 154 (01) : 11 - 13
  • [2] DEROOS A, 1985, THESIS U HOSPITAL LE
  • [3] Dosimetry Working Party of the Institute of physical sciences in medicine, 1992, NAT PROT PAT DOS MEA
  • [4] DROUILLARD J, 1991, Medicamundi, V36, P3
  • [5] HART D, 1993, NATL RADIOLOGICAL R, V262
  • [6] International Commission on Radiological Protection, 1991, REC INT COMM RAD PR, V1st ed.
  • [7] FILTERS FOR RADIATION REDUCTION - A COMPARISON
    KOHN, ML
    GOOCH, AW
    KELLER, WS
    [J]. RADIOLOGY, 1988, 167 (01) : 255 - 257
  • [8] KRAMER R, 1986, S885 I STRAHL GES ST
  • [9] REDUCTION OF PATIENT DOSES FROM BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS THROUGH CHANGES IN EQUIPMENT FACTORS
    MARTIN, CJ
    HUNTER, S
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (804) : 1196 - 1205
  • [10] Computer assisted determination of the dose-area product in retrograde urethrography
    Merkle, E
    Aschoff, AJ
    Muller, M
    Merk, J
    Brambs, HJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) : 262 - 265