The 3D CT superimposition method using image fusion based on the maximum mutual information algorithm for the assessment of oral and maxillofacial surgery treatment results

被引:33
作者
Lee, Jee-Ho [2 ]
Kim, Myung-Jin [1 ]
Kim, Soung-Min [1 ]
Kwon, Oh-Hyung [3 ]
Kim, Yong-Kyeom [4 ]
机构
[1] Seoul Natl Univ Dent Hosp, Dept Oral & Maxillofacial Surg, Seoul 110768, South Korea
[2] Seoul Asan Med Ctr, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[3] Cybermed Inc, Seoul, South Korea
[4] Seoul Dent Hosp Disabled, Seoul, South Korea
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2012年 / 114卷 / 02期
关键词
COMPUTED-TOMOGRAPHY MODELS; TRACING SUPERIMPOSITION; CRANIAL BASE; REGISTRATION; MAXIMIZATION; ACCURACY;
D O I
10.1016/j.tripleo.2011.06.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The usefulness of image fusion based on the maximum mutual information algorithm was investigated for the assessment of oral and maxillofacial surgery treatment results. Study design. Superimposition was performed using image fusion of 25 CBCT images of a human skull under the assumption of different spatial conditions and 41 patients' image data. Errors were measured using distances between titanium markers on the skull. The degree of shared image information was defined as normalized mutual information (NMI) value to assess robustness of image fusion. Results. The mean error was 0.396 mm (+/- 0.142 mm) and was not affected by positional change (P > .05). Mandibular shifts showed significantly different (P = .000) NMI values but shared information was not significantly affected by the degree of surgical changes in patients' CT (P = .176). Conclusions. For the evaluation of surgical treatment results, image fusion is an accurate and reliable method that is not affected by spatial or surgical changes. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:167-174)
引用
收藏
页码:167 / 174
页数:8
相关论文
共 18 条
  • [1] Arat ZM, 2003, ANGLE ORTHOD, V73, P374
  • [2] Basu S, 2009, NUCL MED REV, V12, P1
  • [3] RELIABILITY OF HEAD FILM MEASUREMENTS .3. TRACING SUPERIMPOSITION
    BAUMRIND, S
    MILLER, D
    MOLTHEN, R
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1976, 70 (06) : 617 - 644
  • [4] Superimposition of 3D cone-beam CT models of orthognathic surgery patients
    Cevidanes, LHS
    Bailey, LJ
    Tucker, GR
    Styner, MA
    Mol, A
    Phillips, CL
    Proffit, WR
    Turvey, T
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (06) : 369 - 375
  • [5] Cranial base superimposition for 3-dimensional evaluation of soft-tissue changes
    Cevidanes, Lucia H. C.
    Motta, Alexandre
    Proffit, William R.
    Ackerman, James L.
    Styner, Martin
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S120 - S129
  • [6] Superimposition of 3-dimensional cone-beam computed tomography models of growing patients
    Cevidanes, Lucia H. C.
    Heymann, Gavin
    Cornelis, Marie A.
    DeClerck, Hugo J.
    Tulloch, J. F. Camilla
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 94 - 99
  • [7] Image analysis and superimposition of 3-dimensional cone-beam computed tomography models
    Cevidanes, Lucia H. S.
    Styner, Martin A.
    Proffit, William R.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 129 (05) : 611 - 618
  • [8] Choi Jeong-Ho, 2010, J Clin Orthod, V44, P303
  • [9] CEPHALOMETRIC ERRORS - A COMPARISON BETWEEN REPEAT MEASUREMENTS AND RETAKEN RADIOGRAPHS
    COOKE, MS
    WEI, SHY
    [J]. AUSTRALIAN DENTAL JOURNAL, 1991, 36 (01) : 38 - 43
  • [10] CEPHALOMETRIC SUPERIMPOSITION ON THE CRANIAL BASE - A REVIEW AND A COMPARISON OF 4 METHODS
    GHAFARI, J
    ENGEL, FE
    LASTER, LL