Generic approach to the method development of intact protein separations using hydrophobic interaction chromatography

被引:4
|
作者
Tyteca, Eva [1 ,2 ]
De Vos, Jelle [1 ]
Tassi, Marco [1 ]
Cook, Ken [3 ]
Liu, Xiaodong [4 ]
Kaal, Erwin [5 ]
Eeltink, Sebastiaan [1 ]
机构
[1] VUB, Dept Chem Engn, Brussels, Belgium
[2] Univ Liege Gembloux Agro BioTech, Dept Agron Bioengn & Chem, Analyt Chem, Gembloux, Belgium
[3] Thermo Fisher Sci, Hemel Hempstead, England
[4] Thermo Fisher Sci, Sunnyvale, CA USA
[5] DSM Biotechnol Ctr, Delft, Netherlands
关键词
biopharmaceuticals; HPLC method development; linear solvent-strength model; protein conformations; therapeutic proteins; PRACTICAL METHOD DEVELOPMENT; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODIES; HOFMEISTER SERIES; GRADIENT-ELUTION; RETENTION; PHASE; WATER; OPTIMIZATION; PEPTIDES;
D O I
10.1002/jssc.201701202
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a liquid chromatography method development approach for the separation of intact proteins using hydrophobic interaction chromatography. First, protein retention was determined as function of the salt concentration by isocratic measurements and modeled using linear regression. The error between measured and predicted retention factors was studied while varying gradient time (between 15 and 120 min) and gradient starting conditions, and ranged between 2 and 15%. To reduce the time needed to develop optimized gradient methods for hydrophobic interaction chromatography separations, retention-time estimations were also assessed based on two gradient scouting runs, resulting in significantly improved retention-time predictions (average error < 2.5%) when varying gradient time. When starting the scouting gradient at lower salt concentrations (stronger eluent), retention time prediction became inaccurate in contrast to predictions based on isocratic runs. Application of three scouting runs and a nonlinear model, incorporating the effects of gradient duration and mobile-phase composition at the start of the gradient, provides accurate results (improved fitting compared to the linear solvent-strength model) with an average error of 1.0% and maximum deviation of -8.3%. Finally, gradient scouting runs and retention-time modeling have been applied for the optimization of a critical-pair protein isoform separation encountered in a biotechnological sample.
引用
收藏
页码:1017 / 1024
页数:8
相关论文
共 50 条
  • [31] THEORY AND USE OF HYDROPHOBIC INTERACTION CHROMATOGRAPHY IN PROTEIN PURIFICATION APPLICATIONS
    McCue, Justin T.
    GUIDE TO PROTEIN PURIFICATION, SECOND EDITION, 2009, 463 : 405 - 414
  • [32] Application of hydrophobic interaction displacement chromatography for an industrial protein purification
    Sunasara, KM
    Xia, F
    Gronke, RS
    Cramer, SM
    BIOTECHNOLOGY AND BIOENGINEERING, 2003, 82 (03) : 330 - 339
  • [33] Development of a purification procedure for the placental protein 14 involving metal-chelate affinity chromatography and hydrophobic interaction chromatography
    Berkovsky, AL
    Potapov, PP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 692 (02): : 273 - 279
  • [34] Electrospun Hydrophobic Interaction Chromatography (HIC) Membranes for Protein Purification
    Chen, Shu-Ting
    Wickramasinghe, Sumith Ranil
    Qian, Xianghong
    MEMBRANES, 2022, 12 (07)
  • [35] Synthesis of adsorbents with dendronic structures for protein hydrophobic interaction chromatography
    Mata-Gomez, Marco A.
    Yaman, Sena
    Valencia-Gallegos, Jesus A.
    Tari, Canan
    Rito-Palomares, Marco
    Gonzalez-Valdez, Jose
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 191 - 200
  • [36] Optimal opcration conditions for protein separation in hydrophobic interaction chromatography
    Mahn, Andrea
    Lienqueo, M. Elena
    Asenjo, Juan A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 849 (1-2): : 236 - 242
  • [38] PROTEIN SURFACE-AREA AND RETENTION IN HYDROPHOBIC INTERACTION CHROMATOGRAPHY
    KATTI, A
    MAA, YF
    HORVATH, C
    CHROMATOGRAPHIA, 1987, 24 : 646 - 650
  • [39] Development and Optimization of a Hydrophobic Interaction Chromatography-Based Method of AAV Harvest, Capture, and Recovery
    McNally, David J.
    Piras, Bryan A.
    Willis, Catherine M.
    Lockey, Timothy D.
    Meagher, Michael M.
    MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2020, 19 : 275 - 284
  • [40] An Experimental and Modeling Combined Approach in Preparative Hydrophobic Interaction Chromatography
    Lietta, Elena
    Pieri, Alessandro
    Cardillo, Antonio G.
    Vanni, Marco
    Pisano, Roberto
    Barresi, Antonello A.
    PROCESSES, 2022, 10 (05)