Generic approach to the method development of intact protein separations using hydrophobic interaction chromatography

被引:4
|
作者
Tyteca, Eva [1 ,2 ]
De Vos, Jelle [1 ]
Tassi, Marco [1 ]
Cook, Ken [3 ]
Liu, Xiaodong [4 ]
Kaal, Erwin [5 ]
Eeltink, Sebastiaan [1 ]
机构
[1] VUB, Dept Chem Engn, Brussels, Belgium
[2] Univ Liege Gembloux Agro BioTech, Dept Agron Bioengn & Chem, Analyt Chem, Gembloux, Belgium
[3] Thermo Fisher Sci, Hemel Hempstead, England
[4] Thermo Fisher Sci, Sunnyvale, CA USA
[5] DSM Biotechnol Ctr, Delft, Netherlands
关键词
biopharmaceuticals; HPLC method development; linear solvent-strength model; protein conformations; therapeutic proteins; PRACTICAL METHOD DEVELOPMENT; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODIES; HOFMEISTER SERIES; GRADIENT-ELUTION; RETENTION; PHASE; WATER; OPTIMIZATION; PEPTIDES;
D O I
10.1002/jssc.201701202
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a liquid chromatography method development approach for the separation of intact proteins using hydrophobic interaction chromatography. First, protein retention was determined as function of the salt concentration by isocratic measurements and modeled using linear regression. The error between measured and predicted retention factors was studied while varying gradient time (between 15 and 120 min) and gradient starting conditions, and ranged between 2 and 15%. To reduce the time needed to develop optimized gradient methods for hydrophobic interaction chromatography separations, retention-time estimations were also assessed based on two gradient scouting runs, resulting in significantly improved retention-time predictions (average error < 2.5%) when varying gradient time. When starting the scouting gradient at lower salt concentrations (stronger eluent), retention time prediction became inaccurate in contrast to predictions based on isocratic runs. Application of three scouting runs and a nonlinear model, incorporating the effects of gradient duration and mobile-phase composition at the start of the gradient, provides accurate results (improved fitting compared to the linear solvent-strength model) with an average error of 1.0% and maximum deviation of -8.3%. Finally, gradient scouting runs and retention-time modeling have been applied for the optimization of a critical-pair protein isoform separation encountered in a biotechnological sample.
引用
收藏
页码:1017 / 1024
页数:8
相关论文
共 50 条
  • [1] FAST PROTEIN SEPARATIONS BY HIGH-PERFORMANCE HYDROPHOBIC INTERACTION CHROMATOGRAPHY
    REID, TS
    GISCH, DJ
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1987, 5 (11): : 986 - 989
  • [2] Analysis of recombinant monoclonal antibodies in hydrophilic interaction chromatography: A generic method development approach
    Bobaly, Balazs
    D'Atri, Valentina
    Beck, Alain
    Guillarme, Davy
    Fekete, Szabolcs
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 24 - 32
  • [3] HYDROPHOBIC INTERACTION CHROMATOGRAPHY - A NEW METHOD FOR SUNFLOWER PROTEIN FRACTIONATION
    RAYMOND, J
    AZANZA, JL
    FOTSO, M
    JOURNAL OF CHROMATOGRAPHY, 1981, 212 (02): : 199 - 209
  • [4] MECHANISMS OF PROTEIN RETENTION IN HYDROPHOBIC INTERACTION CHROMATOGRAPHY
    ROETTGER, BF
    MYERS, J
    REGNIER, FE
    LADISCH, MR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 23 - MBTD
  • [5] MECHANISMS OF PROTEIN RETENTION IN HYDROPHOBIC INTERACTION CHROMATOGRAPHY
    ROETTGER, BF
    MYERS, JA
    LADISCH, MR
    REGNIER, FE
    ACS SYMPOSIUM SERIES, 1990, 427 : 80 - 92
  • [6] Prediction of protein retention in hydrophobic interaction chromatography
    Mahn, A
    Asenjo, JA
    BIOTECHNOLOGY ADVANCES, 2005, 23 (05) : 359 - 368
  • [7] A theory of protein-resin interaction in hydrophobic interaction chromatography
    Mahn, A
    Zapata-Torres, G
    Asenjo, JA
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1066 (1-2) : 81 - 88
  • [8] Effects of chromatography conditions on intact protein separations for top-down proteomics
    Wang, YJ
    Balgley, BM
    Rudnick, PA
    Lee, CS
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1073 (1-2) : 35 - 41
  • [9] Modeling of protein monomer/aggregate purification and separation using hydrophobic interaction chromatography
    McCue, Justin T.
    Engel, Philip
    Ng, Austen
    Macniven, Rich
    Thommes, Jorg
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2008, 31 (03) : 261 - 275
  • [10] Modeling of protein monomer/aggregate purification and separation using hydrophobic interaction chromatography
    Justin T. McCue
    Philip Engel
    Austen Ng
    Rich Macniven
    Jörg Thömmes
    Bioprocess and Biosystems Engineering, 2008, 31