Comparison of methods for reduction of lipid contamination for in vivo proton MR spectroscopic imaging of the brain

被引:15
作者
Ebel, A [1 ]
Maudsley, AA [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, DVA Med Ctr, MR Unit 114M, San Francisco, CA 94121 USA
关键词
in vivo MR spectroscopic imaging; proton NMR; brain; lipid contamination; data processing;
D O I
10.1002/mrm.1249
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo proton MR spectroscopic imaging (MRSI) of human brain is complicated by the presence of a strong signal from subcutaneous lipids, which may result in signal contamination in metabolite images obtained following Fourier-transform reconstruction. In this study, two approaches for reduction of lipid contamination-using postprocessing and additional data acquisition-are compared. The first uses extrapolation of k-space information for subcutaneous lipid, which has been applied to data obtained using conventional fully phase-encoded MRSI with circularly sampled k-space or echo-planar spectroscopic imaging (EPSI). The second uses a dual EPSI technique that combines multiple-averaged central k-space data with a single EPSI acquisition of additional information that is used for improved lipid reconstruction. Comparisons are carried out with data obtained from human brain in vivo at 1.5 T with short and medium TEs. Results demonstrate that the performance of both methods for reducing the effects of lipid contamination is similar, and that both are limited by the effects of instrumental instabilities and subject motion, which also depend on the acquisition method used. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:706 / 712
页数:7
相关论文
共 22 条
  • [1] Adalsteinsson E, 1999, MAGNET RESON MED, V42, P314, DOI 10.1002/(SICI)1522-2594(199908)42:2<314::AID-MRM14>3.0.CO
  • [2] 2-X
  • [3] Gradient characterization using a Fourier-transform technique
    Alley, MT
    Glover, GH
    Pelc, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 581 - 587
  • [4] PULSE METHODS FOR SIMPLIFICATION OF PROTEIN NMR-SPECTRA
    CAMPBELL, ID
    DOBSON, CM
    WILLIAMS, RJP
    WRIGHT, PE
    [J]. FEBS LETTERS, 1975, 57 (01) : 96 - 99
  • [5] ELIMINATION OF WATER SIGNAL BY POSTPROCESSING
    DERICHE, M
    HU, XP
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 101 (02) : 229 - 232
  • [6] 3D PHASE ENCODING H-1 SPECTROSCOPIC IMAGING OF HUMAN BRAIN
    DUIJN, JH
    MATSON, GB
    MAUDSLEY, AA
    WEINER, MW
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (02) : 315 - 319
  • [7] Govindaraju V, 2000, NMR BIOMED, V13, P129, DOI 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO
  • [8] 2-V
  • [9] H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING
    HAASE, A
    FRAHM, J
    HANICKE, W
    MATTHAEI, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) : 341 - 344
  • [10] Removal of lipid artifacts in H-1 spectroscopic imaging by data extrapolation
    Haupt, CI
    Schuff, N
    Weiner, MW
    Maudsley, AA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 678 - 687