Volumetric feedback ablation of uterine fibroids using magnetic resonance-guided high intensity focused ultrasound therapy

被引:97
作者
Voogt, M. J. [1 ]
Trillaud, H. [2 ]
Kim, Y. S. [3 ]
Mali, W. P. Th. M. [1 ]
Barkhausen, J. [4 ]
Bartels, L. W. [5 ]
Deckers, R. [5 ]
Frulio, N. [2 ]
Rhim, H. [3 ]
Lim, H. K. [3 ]
Eckey, T. [4 ]
Nieminen, H. J. [6 ]
Mougenot, C. [7 ]
Keserci, B. [8 ]
Soini, J. [6 ]
Vaara, T. [6 ]
Kohler, M. O. [6 ]
Sokka, S. [9 ]
van den Bosch, Maurice A. A. J. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 GX Utrecht, Netherlands
[2] Hosp St Andre, Dept Radiol, Bordeaux, France
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[4] Univ Hosp Schleswig Holstein, Dept Radiol, Lubeck, Germany
[5] Univ Med Ctr Utrecht, Image Sci Inst, Utrecht, Netherlands
[6] Philips Healthcare, Vantaa, Finland
[7] Philips Healthcare, Toronto, ON, Canada
[8] Philips Healthcare, Seoul, South Korea
[9] Philips Healthcare, Andover, MA USA
关键词
Leiomyoma; High intensity focused ultrasound ablation; Ultrasonic therapy; Interventional magnetic resonance imaging; Safety; Uterine fibroid; NONINVASIVE TREATMENT; ARTERY EMBOLIZATION; SURGERY; LEIOMYOMAS; GUIDANCE; OUTCOMES;
D O I
10.1007/s00330-011-2262-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The purpose of this prospective multicenter study was to assess the safety and technical feasibility of volumetric Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) ablation for treatment of patients with symptomatic uterine fibroids. Methods Thirty-three patients with 36 fibroids were treated with volumetric MR-HIFU ablation. Treatment capability and technical feasibility were assessed by comparison of the Non-Perfused Volumes (NPVs) with MR thermal dose predicted treatment volumes. Safety was determined by evaluation of complications or adverse events and unintended lesions. Secondary endpoints were pain and discomfort scores, recovery time and length of hospital stay. Results The mean NPV calculated as a percentage of the total fibroid volume was 21.7%. Correlation between the predicted treatment volumes and NPVs was found to be very strong, with a correlation coefficient r of 0.87. All patients tolerated the treatment well and were treated on an outpatient basis. No serious adverse events were reported and recovery time to normal activities was 2.3 +/- 1.8 days. Conclusion This prospective multicenter study proved that volumetric MR-HIFU is safe and technically feasible for the treatment of symptomatic uterine fibroids. Key Points Magnetic-resonance-guided high intensity focused ultrasound allows non-invasive treatment of uterine fibroids. Volumetric feedback ablation is a novel technology that allows larger treatment volumes MR-guided ultrasound ablation of uterine fibroids appears safe using volumetric feedback.
引用
收藏
页码:411 / 417
页数:7
相关论文
共 27 条
  • [1] Uterine fibroid embolization: a viable alternative to hysterectomy
    Bradley, Linda D.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 201 (02) : 127 - 135
  • [2] BUTTRAM VC, 1981, FERTIL STERIL, V36, P433
  • [3] What are the total costs of surgical treatment for uterine fibroids?
    Carls, Ginger Smith
    Lee, David W.
    Ozminkowski, Ronald J.
    Wang, Shaohung
    Gibson, Teresa B.
    Stewart, Elizabeth
    [J]. JOURNAL OF WOMENS HEALTH, 2008, 17 (07) : 1119 - 1132
  • [4] Thermal ablation of uterine fibroids using MR-guided focused ultrasound-a truly non-invasive treatment modality
    Chapman, Alexander
    ter Haar, Gail
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (10) : 2505 - 2511
  • [5] Improved Volumetric MR-HIFU Ablation by Robust Binary Feedback Control
    Enholm, Julia K.
    Kohler, Max O.
    Quesson, Bruno
    Mougenot, Charles
    Moonen, Chrit T. W.
    Sokka, Shunmugavelu D.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) : 103 - 113
  • [6] Uterine leiomyomas: MR imaging-guided focused ultrasound surgery - Results of different treatment protocols
    Fennessy, Fiona M.
    Tempany, Clare M.
    McDannold, Nathan J.
    So, Minna J.
    Hesley, Gina
    Gostout, Bobbie
    Kim, Hyun S.
    Holland, George A.
    Sarti, Dennis A.
    Hynynen, Kullervo
    Jolesz, Ferenc A.
    Stewart, Elizabeth A.
    [J]. RADIOLOGY, 2007, 243 (03) : 885 - 893
  • [7] Clinical outcomes of magnetic resonance-guided focused ultrasound surgery for uterine myomas: 24-month follow-up
    Funaki, K.
    Fukunishi, H.
    Sawada, K.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 34 (05) : 584 - 589
  • [8] Uterine artery embolization for treatment of leiomyomata - Long-term outcomes from the FIBROID registry
    Goodwin, Scott C.
    Spies, James B.
    Worthington-Kirsch, Robert
    Peterson, Eric
    Pron, Gaylene
    Li, Shuang
    Myers, Evan R.
    [J]. OBSTETRICS AND GYNECOLOGY, 2008, 111 (01) : 22 - 33
  • [9] Noninvasive treatment of uterine fibroids: Early Mayo Clinic experience with magnetic resonance imaging-guided focused ultrasound
    Hesley, Gina K.
    Felmlee, Joel P.
    Gebhart, John B.
    Dunagan, Kelly T.
    Gorny, Krzysztof R.
    Kesler, Jessica B.
    Brandt, Kathleen R.
    Glantz, Janel N.
    Gostout, Bobbi S.
    [J]. MAYO CLINIC PROCEEDINGS, 2006, 81 (07) : 936 - 942
  • [10] MRI guidance of focused ultrasound therapy of uterine fibroids: Early results
    Hindley, J
    Gedroyc, WM
    Regan, L
    Stewart, E
    Tempany, C
    Hynnen, K
    Macdanold, N
    Inbar, Y
    Itzchak, Y
    Rabinovici, J
    Kim, K
    Geschwind, JF
    Hesley, G
    Gostout, B
    Ehrenstein, T
    Hengst, S
    Sklair-Levy, M
    Shushan, A
    Jolesz, F
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (06) : 1713 - 1719