Improving the aseptic transfer procedures in hospital pharmacies part C: evaluation and redesign of the transfer process

被引:2
作者
Boom, Frits A. [1 ]
Le Brun, Paul P. H. [2 ]
Boehringer, Stefan [3 ]
Kosterink, Jos G. W. [4 ]
Touw, Daan J. [4 ]
机构
[1] Zaans Med Ctr, NL-1502 DV Zaandam, Netherlands
[2] Leiden Univ Med Ctr, Dept Clin Pharm & Toxicol, Leiden, Netherlands
[3] Leiden Univ Med Ctr, Med Stat & Bioinformat, Leiden, Netherlands
[4] Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Groningen, Netherlands
关键词
aseptic handling; aseptic transfer process; particle emission; sterile medical device; surface bioburden; MICROBIAL-CONTAMINATION;
D O I
10.1136/ejhpharm-2019-002034
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives To transfer sterile medical devices (SMD), infusion bags (IB), ampoules (A), injection vials (V) and infusion bottles (B) into a laminar airflow cabinet (LAF) or safety cabinet (SC) with a surface bioburden as low as possible. Methods Surface bioburden of the outer layer of SMD, IB, A, V and B was determined by contact plates. Surface bioburden determination of critical spots on A, V and B (ampoule necks and stoppers) was determined by high-recovery swabs and contact plates. Particle emission from white cardboard boxes was determined by a particle counter. Results The chances of a contaminated outer layer of SMD is negligible as long as they stay in their original boxes. The outer layer of double-packed IB can contain a considerable number of micro-organisms. As found in previous studies, the surface bioburden of A, V and B is low as long as they stay in their original cardboard boxes. Particle emission from white boxes is low. The necessity of a final disinfection step inside LAF/SC of critical sspots of A, V and B cannot be proven. SmallSMD, ampoules and injection vials can be transferred into the background areain their original white boxes. Other materials have to be unpacked in front ofthe lock while the operator wear disposable gloves. Disinfection of the outerlayer of IB, before transfer trough the lock, is advised. Tohave materials with a low chance of contamination in LAF/SC, transfer bypresentation for SMD and IB and using a sterile tray for disinfected materialsis an effective procedure. Wiping of ampoule necks and stoppers inside LAF/SC isadvised based on risk assessment. Small SMD, ampoules and injection vials can be transferred into the background areain their original white boxes. Other materials have to be unpacked in front ofthe lock while the operator wear disposable gloves. Disinfection of the outerlayer of IB, before transfer trough the lock, is advised. Conclusion When SMD, ampoules, injection vials and infusion bottles stay in their original boxes as long as possible, the aseptic transfer and the disinfection procedure can be maintained effectively and efficiently.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 14 条
[1]  
Boom F.A., 2015, PRACTICAL PHARM ASEP, P695
[2]   Improving the aseptic transfer procedures in hospital pharmacies. Part B: evaluation of disinfection methods for materials with a non-sterile surface [J].
Boom, Frits A. ;
Le Brun, Paul P. H. ;
Boehringer, Stefan ;
Kosterink, Jos G. W. ;
Touw, Daan .
EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2021, 28 (05) :271-275
[3]   Improving the aseptic transfer procedures in hospital pharmacies part A: methods for the determination of the surface bioburden on ampoules and vials [J].
Boom, Frits A. ;
Le Brun, Paul P. H. ;
Boehringer, Stefan ;
Kosterink, Jos G. W. ;
Touw, Daan .
EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2021, 28 (01) :38-41
[4]  
Cockroft MG., 2001, HOSP PHARM, V8, P226
[5]  
GMP-Hospital Pharmacy Dutch Association of Hospital Pharmacists. Z3, AS HANDL 2013
[6]  
Goverde Marcel, 2017, PDA J Pharm Sci Technol, V71, P33, DOI 10.5731/pdajpst.2016.006783
[7]  
Parenteral Drug Association, 2013, 62 PAR DRUG ASS
[8]  
Sandle T., 2014, CLEANROOM MICROBIOLO, P83
[9]  
Sandle T., 2014, CLEANROOM MICROBIOLO, P141
[10]   Microbial contamination of syringes during preparation: The direct influence of environmental cleanliness and risk manipulations on end-product quality [J].
Stucki, Cyril ;
Sautter, Anna-Maria ;
Favet, Jocelyne ;
Bonnabry, Pascal .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2009, 66 (22) :2032-2036